Cargando…
Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA)
Cytokines are cell signalling proteins that mediate a number of different physiological responses. They are also biomarkers for inflammatory conditions and potential diagnostic references for diseases. Until recently, simultaneous quantification of cytokine profiles had not been possible. Now howeve...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487921/ https://www.ncbi.nlm.nih.gov/pubmed/26150994 http://dx.doi.org/10.1016/j.mex.2015.04.002 |
_version_ | 1782379059702923264 |
---|---|
author | Hall, Sarah A. Stucke, Diana Morrone, Beatrice Lebelt, Dirk Zanella, Adroaldo J. |
author_facet | Hall, Sarah A. Stucke, Diana Morrone, Beatrice Lebelt, Dirk Zanella, Adroaldo J. |
author_sort | Hall, Sarah A. |
collection | PubMed |
description | Cytokines are cell signalling proteins that mediate a number of different physiological responses. They are also biomarkers for inflammatory conditions and potential diagnostic references for diseases. Until recently, simultaneous quantification of cytokine profiles had not been possible. Now however, fluorescent microsphere immunoassays (FMIA) are able to measure multiple cytokines in a single sample. The following pro-inflammatory and anti-inflammatory cytokines were quantified in equine plasma and serum samples: interleukin (IL)-2, IL-4, IL-6, IL-10, interferon (IFN)-γ, tumor necrosis factor (TNF)-α. • The objective of this study was to quantify six equine cytokines simultaneously using the BioPlex(®) 200 system in equine EDTA-plasma and serum. • It demonstrates an increased number of detectable cytokines over published studies. • This technology has the advantage of reduced sample volume and assay time compared to traditional sandwich ELISAs. |
format | Online Article Text |
id | pubmed-4487921 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-44879212015-07-06 Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA) Hall, Sarah A. Stucke, Diana Morrone, Beatrice Lebelt, Dirk Zanella, Adroaldo J. MethodsX Veterinary Science and Veterinary Medicine Cytokines are cell signalling proteins that mediate a number of different physiological responses. They are also biomarkers for inflammatory conditions and potential diagnostic references for diseases. Until recently, simultaneous quantification of cytokine profiles had not been possible. Now however, fluorescent microsphere immunoassays (FMIA) are able to measure multiple cytokines in a single sample. The following pro-inflammatory and anti-inflammatory cytokines were quantified in equine plasma and serum samples: interleukin (IL)-2, IL-4, IL-6, IL-10, interferon (IFN)-γ, tumor necrosis factor (TNF)-α. • The objective of this study was to quantify six equine cytokines simultaneously using the BioPlex(®) 200 system in equine EDTA-plasma and serum. • It demonstrates an increased number of detectable cytokines over published studies. • This technology has the advantage of reduced sample volume and assay time compared to traditional sandwich ELISAs. Elsevier 2015-04-25 /pmc/articles/PMC4487921/ /pubmed/26150994 http://dx.doi.org/10.1016/j.mex.2015.04.002 Text en © 2015 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Veterinary Science and Veterinary Medicine Hall, Sarah A. Stucke, Diana Morrone, Beatrice Lebelt, Dirk Zanella, Adroaldo J. Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA) |
title | Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA) |
title_full | Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA) |
title_fullStr | Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA) |
title_full_unstemmed | Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA) |
title_short | Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA) |
title_sort | simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (fmia) |
topic | Veterinary Science and Veterinary Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487921/ https://www.ncbi.nlm.nih.gov/pubmed/26150994 http://dx.doi.org/10.1016/j.mex.2015.04.002 |
work_keys_str_mv | AT hallsaraha simultaneousdetectionandquantificationofsixequinecytokinesinplasmausingafluorescentmicrosphereimmunoassayfmia AT stuckediana simultaneousdetectionandquantificationofsixequinecytokinesinplasmausingafluorescentmicrosphereimmunoassayfmia AT morronebeatrice simultaneousdetectionandquantificationofsixequinecytokinesinplasmausingafluorescentmicrosphereimmunoassayfmia AT lebeltdirk simultaneousdetectionandquantificationofsixequinecytokinesinplasmausingafluorescentmicrosphereimmunoassayfmia AT zanellaadroaldoj simultaneousdetectionandquantificationofsixequinecytokinesinplasmausingafluorescentmicrosphereimmunoassayfmia |