Cargando…
Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery
PURPOSE: This observational study was designed to evaluate the clinical value of cardiac output (CO) obtained via bioreactance (NICOM™) as compared with values of CO obtained via thermodilution (using pulmonary artery catheter, Vigilance™) and the thoracic bioimpedance (BioZ.com™), in patients under...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Japan
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4488496/ https://www.ncbi.nlm.nih.gov/pubmed/25381090 http://dx.doi.org/10.1007/s00540-014-1938-z |
_version_ | 1782379169036894208 |
---|---|
author | Cheung, Hoiyin Dong, Quan Dong, Rong Yu, Buwei |
author_facet | Cheung, Hoiyin Dong, Quan Dong, Rong Yu, Buwei |
author_sort | Cheung, Hoiyin |
collection | PubMed |
description | PURPOSE: This observational study was designed to evaluate the clinical value of cardiac output (CO) obtained via bioreactance (NICOM™) as compared with values of CO obtained via thermodilution (using pulmonary artery catheter, Vigilance™) and the thoracic bioimpedance (BioZ.com™), in patients undergoing off-pump coronary artery bypass surgery. METHODS: Fifty American Society of Anesthesiologists physical status I–III patients, aged 38–81 years, scheduled for off-pump coronary artery bypass surgery were enrolled in this study. CO data (NCO, BCO, PCO) were recorded during the operative period at ten time points after stable hemodynamic conditions were achieved. RESULTS: The equation of the relationship between the PCO and NCO is PCO = 0.945 × NCO + 0.328 (r = 0.77), and that of PCO and BCO is PCO = 0.965 × BCO + 0.729 (r = 0.63). Furthermore, no statistical difference was found between PCO versus NCO (mean (SD): 4.4 (1.1) versus 4.4 (0.9), p = 0.431). A significant correlation was found between PCO and NCO (r = 0.77, p < 0.001). Correlation was also found between PCO and BCO (r = 0.63, p < 0.001). CONCLUSIONS: The NICOM device is a safe, convenient, and reliable device for measuring continuous non-invasive cardiac output and cardiac index, and the trends of change in CO during the surgery are similar between NICOM and PAC. |
format | Online Article Text |
id | pubmed-4488496 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer Japan |
record_format | MEDLINE/PubMed |
spelling | pubmed-44884962015-07-07 Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery Cheung, Hoiyin Dong, Quan Dong, Rong Yu, Buwei J Anesth Original Article PURPOSE: This observational study was designed to evaluate the clinical value of cardiac output (CO) obtained via bioreactance (NICOM™) as compared with values of CO obtained via thermodilution (using pulmonary artery catheter, Vigilance™) and the thoracic bioimpedance (BioZ.com™), in patients undergoing off-pump coronary artery bypass surgery. METHODS: Fifty American Society of Anesthesiologists physical status I–III patients, aged 38–81 years, scheduled for off-pump coronary artery bypass surgery were enrolled in this study. CO data (NCO, BCO, PCO) were recorded during the operative period at ten time points after stable hemodynamic conditions were achieved. RESULTS: The equation of the relationship between the PCO and NCO is PCO = 0.945 × NCO + 0.328 (r = 0.77), and that of PCO and BCO is PCO = 0.965 × BCO + 0.729 (r = 0.63). Furthermore, no statistical difference was found between PCO versus NCO (mean (SD): 4.4 (1.1) versus 4.4 (0.9), p = 0.431). A significant correlation was found between PCO and NCO (r = 0.77, p < 0.001). Correlation was also found between PCO and BCO (r = 0.63, p < 0.001). CONCLUSIONS: The NICOM device is a safe, convenient, and reliable device for measuring continuous non-invasive cardiac output and cardiac index, and the trends of change in CO during the surgery are similar between NICOM and PAC. Springer Japan 2014-11-08 2015 /pmc/articles/PMC4488496/ /pubmed/25381090 http://dx.doi.org/10.1007/s00540-014-1938-z Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Article Cheung, Hoiyin Dong, Quan Dong, Rong Yu, Buwei Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery |
title | Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery |
title_full | Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery |
title_fullStr | Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery |
title_full_unstemmed | Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery |
title_short | Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery |
title_sort | correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (nicom) and thermodilution in patients undergoing off-pump coronary artery bypass surgery |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4488496/ https://www.ncbi.nlm.nih.gov/pubmed/25381090 http://dx.doi.org/10.1007/s00540-014-1938-z |
work_keys_str_mv | AT cheunghoiyin correlationofcardiacoutputmeasuredbynoninvasivecontinuouscardiacoutputmonitoringnicomandthermodilutioninpatientsundergoingoffpumpcoronaryarterybypasssurgery AT dongquan correlationofcardiacoutputmeasuredbynoninvasivecontinuouscardiacoutputmonitoringnicomandthermodilutioninpatientsundergoingoffpumpcoronaryarterybypasssurgery AT dongrong correlationofcardiacoutputmeasuredbynoninvasivecontinuouscardiacoutputmonitoringnicomandthermodilutioninpatientsundergoingoffpumpcoronaryarterybypasssurgery AT yubuwei correlationofcardiacoutputmeasuredbynoninvasivecontinuouscardiacoutputmonitoringnicomandthermodilutioninpatientsundergoingoffpumpcoronaryarterybypasssurgery |