Cargando…

Acute Cholangitis following Biliary Obstruction after Duodenal OTSC Placement in a Case of Large Chronic Duodenocutaneous Fistula

Over-the-Scope Clip system, also called “Bear Claw,” is a novel endoscopic modality used for closure of gastrointestinal defect with high efficacy and safety. We present a patient with history of eosinophilic gastroenteritis and multiple abdominal surgeries including Billroth II gastrectomy complica...

Descripción completa

Detalles Bibliográficos
Autores principales: Alastal, Yaseen, Hammad, Tariq A., Nawras, Mohamad, Khalil, Basmah W., Alaradi, Osama, Nawras, Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4491398/
https://www.ncbi.nlm.nih.gov/pubmed/26185690
http://dx.doi.org/10.1155/2015/647806
Descripción
Sumario:Over-the-Scope Clip system, also called “Bear Claw,” is a novel endoscopic modality used for closure of gastrointestinal defect with high efficacy and safety. We present a patient with history of eosinophilic gastroenteritis and multiple abdominal surgeries including Billroth II gastrectomy complicated by a large chronic duodenocutaneous fistula from a Billroth II afferent limb to the abdominal wall. Bear Claw clip was used for closure of this fistula. The patient developed acute cholangitis one day after placement of the Bear Claw clip. Acute cholangitis due to papillary obstruction is a potential complication of Bear Claw placement at the dome of the duodenal stump (afferent limb) in patient with Billroth II surgery due to its close proximity to the major papilla.