Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ

We report use of U-shaped biconically tapered optical fibers (BTOF) as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G) and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-anti...

Descripción completa

Detalles Bibliográficos
Autores principales: Miller, John, Castaneda, Angelica, Lee, Kun Ho, Sanchez, Martin, Ortiz, Adrian, Almaz, Ekrem, Turkoglu Almaz, Zuleyha, Murinda, Shelton, Lin, Wei-Jen, Salik, Ertan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4493543/
https://www.ncbi.nlm.nih.gov/pubmed/25836359
http://dx.doi.org/10.3390/bios5020158
_version_ 1782379938050998272
author Miller, John
Castaneda, Angelica
Lee, Kun Ho
Sanchez, Martin
Ortiz, Adrian
Almaz, Ekrem
Turkoglu Almaz, Zuleyha
Murinda, Shelton
Lin, Wei-Jen
Salik, Ertan
author_facet Miller, John
Castaneda, Angelica
Lee, Kun Ho
Sanchez, Martin
Ortiz, Adrian
Almaz, Ekrem
Turkoglu Almaz, Zuleyha
Murinda, Shelton
Lin, Wei-Jen
Salik, Ertan
author_sort Miller, John
collection PubMed
description We report use of U-shaped biconically tapered optical fibers (BTOF) as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G) and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G)-antigen (rabbit anti-mouse IgG) reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.
format Online
Article
Text
id pubmed-4493543
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-44935432015-07-07 Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ Miller, John Castaneda, Angelica Lee, Kun Ho Sanchez, Martin Ortiz, Adrian Almaz, Ekrem Turkoglu Almaz, Zuleyha Murinda, Shelton Lin, Wei-Jen Salik, Ertan Biosensors (Basel) Article We report use of U-shaped biconically tapered optical fibers (BTOF) as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G) and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G)-antigen (rabbit anti-mouse IgG) reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method. MDPI 2015-04-01 /pmc/articles/PMC4493543/ /pubmed/25836359 http://dx.doi.org/10.3390/bios5020158 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Miller, John
Castaneda, Angelica
Lee, Kun Ho
Sanchez, Martin
Ortiz, Adrian
Almaz, Ekrem
Turkoglu Almaz, Zuleyha
Murinda, Shelton
Lin, Wei-Jen
Salik, Ertan
Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ
title Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ
title_full Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ
title_fullStr Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ
title_full_unstemmed Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ
title_short Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays ǂ
title_sort biconically tapered fiber optic probes for rapid label-free immunoassays ǂ
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4493543/
https://www.ncbi.nlm.nih.gov/pubmed/25836359
http://dx.doi.org/10.3390/bios5020158
work_keys_str_mv AT millerjohn biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT castanedaangelica biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT leekunho biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT sanchezmartin biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT ortizadrian biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT almazekrem biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT turkoglualmazzuleyha biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT murindashelton biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT linweijen biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ
AT salikertan biconicallytaperedfiberopticprobesforrapidlabelfreeimmunoassaysǂ