A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction

This paper presents a comparative study in physiological monitoring between a wearable opto-electronic patch sensor (OEPS) comprising a three-axis Microelectromechanical systems (MEMs) accelerometer (3MA) and commercial devices. The study aims to effectively capture critical physiological parameters...

Descripción completa

Detalles Bibliográficos
Autores principales: Alzahrani, Abdullah, Hu, Sijung, Azorin-Peris, Vicente
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4493550/
https://www.ncbi.nlm.nih.gov/pubmed/26061828
http://dx.doi.org/10.3390/bios5020288
_version_ 1782379939586113536
author Alzahrani, Abdullah
Hu, Sijung
Azorin-Peris, Vicente
author_facet Alzahrani, Abdullah
Hu, Sijung
Azorin-Peris, Vicente
author_sort Alzahrani, Abdullah
collection PubMed
description This paper presents a comparative study in physiological monitoring between a wearable opto-electronic patch sensor (OEPS) comprising a three-axis Microelectromechanical systems (MEMs) accelerometer (3MA) and commercial devices. The study aims to effectively capture critical physiological parameters, for instance, oxygen saturation, heart rate, respiration rate and heart rate variability, as extracted from the pulsatile waveforms captured by OEPS against motion artefacts when using the commercial probe. The protocol involved 16 healthy subjects and was designed to test the features of OEPS, with emphasis on the effective reduction of motion artefacts through the utilization of a 3MA as a movement reference. The results show significant agreement between the heart rates from the reference measurements and the recovered signals. Significance of standard deviation and error of mean yield values of 2.27 and 0.65 beats per minute, respectively; and a high correlation (0.97) between the results of the commercial sensor and OEPS. T, Wilcoxon and Bland-Altman with 95% limit of agreement tests were also applied in the comparison of heart rates extracted from these sensors, yielding a mean difference (MD: 0.08). The outcome of the present work incites the prospects of OEPS on physiological monitoring during physical activities.
format Online
Article
Text
id pubmed-4493550
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-44935502015-07-07 A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction Alzahrani, Abdullah Hu, Sijung Azorin-Peris, Vicente Biosensors (Basel) Article This paper presents a comparative study in physiological monitoring between a wearable opto-electronic patch sensor (OEPS) comprising a three-axis Microelectromechanical systems (MEMs) accelerometer (3MA) and commercial devices. The study aims to effectively capture critical physiological parameters, for instance, oxygen saturation, heart rate, respiration rate and heart rate variability, as extracted from the pulsatile waveforms captured by OEPS against motion artefacts when using the commercial probe. The protocol involved 16 healthy subjects and was designed to test the features of OEPS, with emphasis on the effective reduction of motion artefacts through the utilization of a 3MA as a movement reference. The results show significant agreement between the heart rates from the reference measurements and the recovered signals. Significance of standard deviation and error of mean yield values of 2.27 and 0.65 beats per minute, respectively; and a high correlation (0.97) between the results of the commercial sensor and OEPS. T, Wilcoxon and Bland-Altman with 95% limit of agreement tests were also applied in the comparison of heart rates extracted from these sensors, yielding a mean difference (MD: 0.08). The outcome of the present work incites the prospects of OEPS on physiological monitoring during physical activities. MDPI 2015-06-08 /pmc/articles/PMC4493550/ /pubmed/26061828 http://dx.doi.org/10.3390/bios5020288 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Alzahrani, Abdullah
Hu, Sijung
Azorin-Peris, Vicente
A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction
title A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction
title_full A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction
title_fullStr A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction
title_full_unstemmed A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction
title_short A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction
title_sort comparative study of physiological monitoring with a wearable opto-electronic patch sensor (oeps) for motion reduction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4493550/
https://www.ncbi.nlm.nih.gov/pubmed/26061828
http://dx.doi.org/10.3390/bios5020288
work_keys_str_mv AT alzahraniabdullah acomparativestudyofphysiologicalmonitoringwithawearableoptoelectronicpatchsensoroepsformotionreduction
AT husijung acomparativestudyofphysiologicalmonitoringwithawearableoptoelectronicpatchsensoroepsformotionreduction
AT azorinperisvicente acomparativestudyofphysiologicalmonitoringwithawearableoptoelectronicpatchsensoroepsformotionreduction
AT alzahraniabdullah comparativestudyofphysiologicalmonitoringwithawearableoptoelectronicpatchsensoroepsformotionreduction
AT husijung comparativestudyofphysiologicalmonitoringwithawearableoptoelectronicpatchsensoroepsformotionreduction
AT azorinperisvicente comparativestudyofphysiologicalmonitoringwithawearableoptoelectronicpatchsensoroepsformotionreduction