Cargando…

How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery

Background: In radiosurgery, the convention has been to prescribe radiation dose to a “covering isodose volume”. This is presumed to be the minimum dose received by the entire tumor. Our purpose was to review our practice, assess different means of specifying a prescription isodose, and test how rel...

Descripción completa

Detalles Bibliográficos
Autores principales: Roberge, David, Leclerc-Champagne, Claudie, Doucet, Robert, Seuntjens, Jan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4494511/
https://www.ncbi.nlm.nih.gov/pubmed/26180706
http://dx.doi.org/10.7759/cureus.282
_version_ 1782380109494222848
author Roberge, David
Leclerc-Champagne, Claudie
Doucet, Robert
Seuntjens, Jan
author_facet Roberge, David
Leclerc-Champagne, Claudie
Doucet, Robert
Seuntjens, Jan
author_sort Roberge, David
collection PubMed
description Background: In radiosurgery, the convention has been to prescribe radiation dose to a “covering isodose volume”. This is presumed to be the minimum dose received by the entire tumor. Our purpose was to review our practice, assess different means of specifying a prescription isodose, and test how reliable they were in the face of various calculation methodologies. Methods: Different minimum doses were calculated using three calculation methods for 20 brain targets and compared to the original physician intent. Monte Carlo (MC) calculations were run down to 2% (1 sigma) statistics. Voxel size depended on the imaging field of view and the calculation engine. For pencil beam convolution ("finite size pencil beam" - FSPB) calculations with or without heterogeneity correction (Methods 1-2), the calculation grid matched the CT scan resolution. For MC calculations (Method 3), the highest available in-plane resolution was 256 x 256 pixels. The median voxel volume was thus 0.58 mm(3) (0.47 to 0.95 mm(3)) for FSPB and 2.3 mm(3) (1.87 to 3.80) for MC. Results: The absolute minimum target dose varied substantially between the three calculation methods — up to 25% difference between Methods 1 and 3. The differences were reduced when comparing near-minimum doses with absolute minimal volumes ΔV, DPTV-ΔV. The median difference in the isodose covering the PTV-0.03 cm(3) was 0% for Methods 1 and 2 and 3.6% for Methods 1 and 3. The median difference in the isodose covering the PTV-0.01 cm(3) was 0% for Methods 1 and 2 and 2.2% for Methods 1 and 3. In our data, the smaller the volume in which the minimum dose is calculated, the more sensitive this calculation was to dose calculation parameters. The standard deviation of the difference between physician intent and the isodose covering the PTV-0.01 cm(3) was 2.9% (range from -3.3% to 9.3%). Conclusion: In radiosurgery, absolute minimum doses are sensitive to changes in dose calculation grids and dose calculation algorithms. Based on our experience, standardizing dose prescription to the isodose volume covering the PTV-0.01 cm(3) or the PTV-0.03 cm(3) would have little impact on clinical practice and would be relatively insensitive to dose calculation parameters.
format Online
Article
Text
id pubmed-4494511
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-44945112015-07-15 How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery Roberge, David Leclerc-Champagne, Claudie Doucet, Robert Seuntjens, Jan Cureus Medical Physics Background: In radiosurgery, the convention has been to prescribe radiation dose to a “covering isodose volume”. This is presumed to be the minimum dose received by the entire tumor. Our purpose was to review our practice, assess different means of specifying a prescription isodose, and test how reliable they were in the face of various calculation methodologies. Methods: Different minimum doses were calculated using three calculation methods for 20 brain targets and compared to the original physician intent. Monte Carlo (MC) calculations were run down to 2% (1 sigma) statistics. Voxel size depended on the imaging field of view and the calculation engine. For pencil beam convolution ("finite size pencil beam" - FSPB) calculations with or without heterogeneity correction (Methods 1-2), the calculation grid matched the CT scan resolution. For MC calculations (Method 3), the highest available in-plane resolution was 256 x 256 pixels. The median voxel volume was thus 0.58 mm(3) (0.47 to 0.95 mm(3)) for FSPB and 2.3 mm(3) (1.87 to 3.80) for MC. Results: The absolute minimum target dose varied substantially between the three calculation methods — up to 25% difference between Methods 1 and 3. The differences were reduced when comparing near-minimum doses with absolute minimal volumes ΔV, DPTV-ΔV. The median difference in the isodose covering the PTV-0.03 cm(3) was 0% for Methods 1 and 2 and 3.6% for Methods 1 and 3. The median difference in the isodose covering the PTV-0.01 cm(3) was 0% for Methods 1 and 2 and 2.2% for Methods 1 and 3. In our data, the smaller the volume in which the minimum dose is calculated, the more sensitive this calculation was to dose calculation parameters. The standard deviation of the difference between physician intent and the isodose covering the PTV-0.01 cm(3) was 2.9% (range from -3.3% to 9.3%). Conclusion: In radiosurgery, absolute minimum doses are sensitive to changes in dose calculation grids and dose calculation algorithms. Based on our experience, standardizing dose prescription to the isodose volume covering the PTV-0.01 cm(3) or the PTV-0.03 cm(3) would have little impact on clinical practice and would be relatively insensitive to dose calculation parameters. Cureus 2015-06-29 /pmc/articles/PMC4494511/ /pubmed/26180706 http://dx.doi.org/10.7759/cureus.282 Text en Copyright © 2015, Roberge et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Physics
Roberge, David
Leclerc-Champagne, Claudie
Doucet, Robert
Seuntjens, Jan
How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery
title How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery
title_full How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery
title_fullStr How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery
title_full_unstemmed How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery
title_short How Low Should You Go: Choice of Minimum Dose Prescription in Cranial Radiosurgery
title_sort how low should you go: choice of minimum dose prescription in cranial radiosurgery
topic Medical Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4494511/
https://www.ncbi.nlm.nih.gov/pubmed/26180706
http://dx.doi.org/10.7759/cureus.282
work_keys_str_mv AT robergedavid howlowshouldyougochoiceofminimumdoseprescriptionincranialradiosurgery
AT leclercchampagneclaudie howlowshouldyougochoiceofminimumdoseprescriptionincranialradiosurgery
AT doucetrobert howlowshouldyougochoiceofminimumdoseprescriptionincranialradiosurgery
AT seuntjensjan howlowshouldyougochoiceofminimumdoseprescriptionincranialradiosurgery