Cargando…

Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model

PURPOSE: Capsular contracture is the most frequent long-term complication after implant-based breast reconstruction or augmentation. The aim of this study was to evaluate the impact of implant surface properties on fibrotic capsule formation in an animal model. MATERIALS AND METHODS: Twenty-four rat...

Descripción completa

Detalles Bibliográficos
Autores principales: Fischer, Sebastian, Hirche, Christoph, Reichenberger, Matthias A., Kiefer, Jurij, Diehm, Yannick, Mukundan, Srinivasan, Alhefzi, Muayyad, Bueno, Ericka M., Kneser, Ulrich, Pomahac, Bohdan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4495016/
https://www.ncbi.nlm.nih.gov/pubmed/26151888
http://dx.doi.org/10.1371/journal.pone.0132131
_version_ 1782380185709969408
author Fischer, Sebastian
Hirche, Christoph
Reichenberger, Matthias A.
Kiefer, Jurij
Diehm, Yannick
Mukundan, Srinivasan
Alhefzi, Muayyad
Bueno, Ericka M.
Kneser, Ulrich
Pomahac, Bohdan
author_facet Fischer, Sebastian
Hirche, Christoph
Reichenberger, Matthias A.
Kiefer, Jurij
Diehm, Yannick
Mukundan, Srinivasan
Alhefzi, Muayyad
Bueno, Ericka M.
Kneser, Ulrich
Pomahac, Bohdan
author_sort Fischer, Sebastian
collection PubMed
description PURPOSE: Capsular contracture is the most frequent long-term complication after implant-based breast reconstruction or augmentation. The aim of this study was to evaluate the impact of implant surface properties on fibrotic capsule formation in an animal model. MATERIALS AND METHODS: Twenty-four rats received 1 scaled down silicone implant each; 12 of the rats received implants with textured surfaces, and the other 12 received implants with smooth surfaces. After 60 and 120 days, rats in each group underwent 7-Tesla Magnetic Resonance Imaging (MRI) and high-resolution ultrasound (HR-US), and specimens of the capsules were acquired and used to measure capsule thickness through histology, collagen density through picro sirius red staining, and analyses of expression of pro-fibrotic and inflammatory genes (Collagen1-4, TGFb1, TGFb3, Smad3, IL4, IL10, IL13, CD68) through qRT-PCR. Furthermore, MRI data were processed to obtain capsule volume and implant surface area. RESULTS: On day 60, histology and HR-US showed that fibrotic capsules were significantly thicker in the textured implant group with respect to the smooth implant group (p<0.05). However, this difference did not persist on day 120 (p=0.56). Capsule thickness decreased significantly over the study period in both smooth and textured implant groups (p<0.05). Thickness measurements were substantiated by MRI analysis and volumes changed accordingly. Implant surface area did not vary between study dates, but it was different between implant types. On day 60, the density of collagen in the fibrotic capsules was significantly lower in the textured implant group with respect to the smooth group (p<0.05), but again this difference did not persist on day 120 (p=0.67). Collagen 1 and CD68 were respectively over- and under expressed in the textured implant group on day 60. Significant differences in the expression of other genes were not observed. CONCLUSION: Silicone implants with textured surfaces led to temporarily thicker but less dense fibrotic capsules compared with smooth surfaces. 7-Tesla MRI and HR-US are capable for non-invasive in-vivo assessment of capsular fibrosis in an animal model and can provide unique insights into the fibrotic process by 3D reconstruction and surface area measurement.
format Online
Article
Text
id pubmed-4495016
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44950162015-07-15 Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model Fischer, Sebastian Hirche, Christoph Reichenberger, Matthias A. Kiefer, Jurij Diehm, Yannick Mukundan, Srinivasan Alhefzi, Muayyad Bueno, Ericka M. Kneser, Ulrich Pomahac, Bohdan PLoS One Research Article PURPOSE: Capsular contracture is the most frequent long-term complication after implant-based breast reconstruction or augmentation. The aim of this study was to evaluate the impact of implant surface properties on fibrotic capsule formation in an animal model. MATERIALS AND METHODS: Twenty-four rats received 1 scaled down silicone implant each; 12 of the rats received implants with textured surfaces, and the other 12 received implants with smooth surfaces. After 60 and 120 days, rats in each group underwent 7-Tesla Magnetic Resonance Imaging (MRI) and high-resolution ultrasound (HR-US), and specimens of the capsules were acquired and used to measure capsule thickness through histology, collagen density through picro sirius red staining, and analyses of expression of pro-fibrotic and inflammatory genes (Collagen1-4, TGFb1, TGFb3, Smad3, IL4, IL10, IL13, CD68) through qRT-PCR. Furthermore, MRI data were processed to obtain capsule volume and implant surface area. RESULTS: On day 60, histology and HR-US showed that fibrotic capsules were significantly thicker in the textured implant group with respect to the smooth implant group (p<0.05). However, this difference did not persist on day 120 (p=0.56). Capsule thickness decreased significantly over the study period in both smooth and textured implant groups (p<0.05). Thickness measurements were substantiated by MRI analysis and volumes changed accordingly. Implant surface area did not vary between study dates, but it was different between implant types. On day 60, the density of collagen in the fibrotic capsules was significantly lower in the textured implant group with respect to the smooth group (p<0.05), but again this difference did not persist on day 120 (p=0.67). Collagen 1 and CD68 were respectively over- and under expressed in the textured implant group on day 60. Significant differences in the expression of other genes were not observed. CONCLUSION: Silicone implants with textured surfaces led to temporarily thicker but less dense fibrotic capsules compared with smooth surfaces. 7-Tesla MRI and HR-US are capable for non-invasive in-vivo assessment of capsular fibrosis in an animal model and can provide unique insights into the fibrotic process by 3D reconstruction and surface area measurement. Public Library of Science 2015-07-07 /pmc/articles/PMC4495016/ /pubmed/26151888 http://dx.doi.org/10.1371/journal.pone.0132131 Text en © 2015 Fischer et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Fischer, Sebastian
Hirche, Christoph
Reichenberger, Matthias A.
Kiefer, Jurij
Diehm, Yannick
Mukundan, Srinivasan
Alhefzi, Muayyad
Bueno, Ericka M.
Kneser, Ulrich
Pomahac, Bohdan
Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model
title Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model
title_full Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model
title_fullStr Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model
title_full_unstemmed Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model
title_short Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model
title_sort silicone implants with smooth surfaces induce thinner but denser fibrotic capsules compared to those with textured surfaces in a rodent model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4495016/
https://www.ncbi.nlm.nih.gov/pubmed/26151888
http://dx.doi.org/10.1371/journal.pone.0132131
work_keys_str_mv AT fischersebastian siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT hirchechristoph siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT reichenbergermatthiasa siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT kieferjurij siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT diehmyannick siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT mukundansrinivasan siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT alhefzimuayyad siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT buenoerickam siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT kneserulrich siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel
AT pomahacbohdan siliconeimplantswithsmoothsurfacesinducethinnerbutdenserfibroticcapsulescomparedtothosewithtexturedsurfacesinarodentmodel