Cargando…

1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump

NMR is used to measure sodium flow driven by a 1D concentration gradient inside poly-acrylamid (pAA) hydrogel. A sodium concentration jump from 0.5 M NaCl to 0 M NaCl is applied at the bottom of a cylindrical pAA sample. The sodium level and hydrogen level are measured as a function of time and posi...

Descripción completa

Detalles Bibliográficos
Autores principales: Roos, R. W., Pel, L., Huinink, H. P., Huyghe, J. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4495263/
https://www.ncbi.nlm.nih.gov/pubmed/25786888
http://dx.doi.org/10.1007/s10439-015-1293-8
_version_ 1782380224370966528
author Roos, R. W.
Pel, L.
Huinink, H. P.
Huyghe, J. M.
author_facet Roos, R. W.
Pel, L.
Huinink, H. P.
Huyghe, J. M.
author_sort Roos, R. W.
collection PubMed
description NMR is used to measure sodium flow driven by a 1D concentration gradient inside poly-acrylamid (pAA) hydrogel. A sodium concentration jump from 0.5 M NaCl to 0 M NaCl is applied at the bottom of a cylindrical pAA sample. The sodium level and hydrogen level are measured as a function of time and position inside the sample for 5 days. Then a reversed step is applied, and ion flow is measured for another 5 days. During the measurement, the cylindrical sample is radially confined and allowed to swell in the axial direction. At the same time, sodium and moisture in the sample are measured on a 1D spatial grid in the axial direction. A quadriphasic mixture model (Huyghe and Janssen in Int J Eng Sci 35:793, 1997) is used to simulate the results and estimate the diffusion coefficient of sodium and chloride. The best fit results were obtained for D[Formula: see text] cm(2)/s and D[Formula: see text] cm(2)/s, at 25 degrees centigrade. Different time constants were observed for swelling and deswelling.
format Online
Article
Text
id pubmed-4495263
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-44952632015-07-09 1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump Roos, R. W. Pel, L. Huinink, H. P. Huyghe, J. M. Ann Biomed Eng Article NMR is used to measure sodium flow driven by a 1D concentration gradient inside poly-acrylamid (pAA) hydrogel. A sodium concentration jump from 0.5 M NaCl to 0 M NaCl is applied at the bottom of a cylindrical pAA sample. The sodium level and hydrogen level are measured as a function of time and position inside the sample for 5 days. Then a reversed step is applied, and ion flow is measured for another 5 days. During the measurement, the cylindrical sample is radially confined and allowed to swell in the axial direction. At the same time, sodium and moisture in the sample are measured on a 1D spatial grid in the axial direction. A quadriphasic mixture model (Huyghe and Janssen in Int J Eng Sci 35:793, 1997) is used to simulate the results and estimate the diffusion coefficient of sodium and chloride. The best fit results were obtained for D[Formula: see text] cm(2)/s and D[Formula: see text] cm(2)/s, at 25 degrees centigrade. Different time constants were observed for swelling and deswelling. Springer US 2015-03-19 2015 /pmc/articles/PMC4495263/ /pubmed/25786888 http://dx.doi.org/10.1007/s10439-015-1293-8 Text en © The Author(s) 2015 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Article
Roos, R. W.
Pel, L.
Huinink, H. P.
Huyghe, J. M.
1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump
title 1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump
title_full 1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump
title_fullStr 1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump
title_full_unstemmed 1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump
title_short 1D Measurement of Sodium Ion Flow in Hydrogel After a Bath Concentration Jump
title_sort 1d measurement of sodium ion flow in hydrogel after a bath concentration jump
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4495263/
https://www.ncbi.nlm.nih.gov/pubmed/25786888
http://dx.doi.org/10.1007/s10439-015-1293-8
work_keys_str_mv AT roosrw 1dmeasurementofsodiumionflowinhydrogelafterabathconcentrationjump
AT pell 1dmeasurementofsodiumionflowinhydrogelafterabathconcentrationjump
AT huininkhp 1dmeasurementofsodiumionflowinhydrogelafterabathconcentrationjump
AT huyghejm 1dmeasurementofsodiumionflowinhydrogelafterabathconcentrationjump