Cargando…
A novel device for assessing dark adaptation in field settings
BACKGROUND: Aberrant dark adaptation is common to many ocular diseases and pathophysiological conditions, including vitamin A deficiency, cardiopulmonary diseases, and hypoxia. Scotopic vision and pupillary responsiveness have typically been measured using subjective, time-consuming methods. Existin...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4496941/ https://www.ncbi.nlm.nih.gov/pubmed/26156587 http://dx.doi.org/10.1186/s12886-015-0062-7 |
_version_ | 1782380489893478400 |
---|---|
author | Labrique, Alain B. Palmer, Amanda C. Healy, Katherine Mehra, Sucheta Sauer, Theodor C. West, Keith P. Sommer, Alfred |
author_facet | Labrique, Alain B. Palmer, Amanda C. Healy, Katherine Mehra, Sucheta Sauer, Theodor C. West, Keith P. Sommer, Alfred |
author_sort | Labrique, Alain B. |
collection | PubMed |
description | BACKGROUND: Aberrant dark adaptation is common to many ocular diseases and pathophysiological conditions, including vitamin A deficiency, cardiopulmonary diseases, and hypoxia. Scotopic vision and pupillary responsiveness have typically been measured using subjective, time-consuming methods. Existing techniques are particularly challenging for use in developing country settings, where vitamin A deficiency remains a major public health problem. Our aim was design a compact, low cost, and easily operated device to assess dark adaptation in the field. METHODS: The Portable Field Dark Adaptometer (PFDA) incorporates a digital camera, a retinal bleaching flash, and a Ganzfeld light source inside a pair of light-obscuring goggles. After a ~10 min period of dark adaption, the infrared camera digitally records afferent pupillary responses to graded light stimuli (−2.9 to 0.1 log cd/m(2)). We tested this device in a variety of field settings to assess: a) ease of use and b) whether test data could clearly and accurately depict the well-known dose-response relationship between light intensity and pupil contraction. A total of 822 videos were collected. We used an open source video analysis software to measure pupil size in pixel units. Pupillary responsiveness was expressed as the percent change in pupil size from pre- to post-light exposure. Box plots, t test, and multi-level mixed effects linear regression modeling were used to characterize the relationship between light intensity and pupillary response. RESULTS: The PFDA was employed with only minor technical challenges in Bangladesh, Kenya, Zambia, and Peru. Our data show a clear linear increase in pupillary constriction with increasing log light intensity. Light intensity was a strong predictor of pupillary response, regardless of baseline pupil size. CONCLUSIONS: The consistent physiological response demonstrated here supports the use of the PFDA as a reliable tool to measure dark adaptation. As a next step, PFDA measurements will be validated against biochemical indicators of vitamin A status and hypoxemia. Ultimately, this new technology may provide a novel approach for nutritional assessment, with potential clinical applications. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12886-015-0062-7) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4496941 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-44969412015-07-10 A novel device for assessing dark adaptation in field settings Labrique, Alain B. Palmer, Amanda C. Healy, Katherine Mehra, Sucheta Sauer, Theodor C. West, Keith P. Sommer, Alfred BMC Ophthalmol Technical Advance BACKGROUND: Aberrant dark adaptation is common to many ocular diseases and pathophysiological conditions, including vitamin A deficiency, cardiopulmonary diseases, and hypoxia. Scotopic vision and pupillary responsiveness have typically been measured using subjective, time-consuming methods. Existing techniques are particularly challenging for use in developing country settings, where vitamin A deficiency remains a major public health problem. Our aim was design a compact, low cost, and easily operated device to assess dark adaptation in the field. METHODS: The Portable Field Dark Adaptometer (PFDA) incorporates a digital camera, a retinal bleaching flash, and a Ganzfeld light source inside a pair of light-obscuring goggles. After a ~10 min period of dark adaption, the infrared camera digitally records afferent pupillary responses to graded light stimuli (−2.9 to 0.1 log cd/m(2)). We tested this device in a variety of field settings to assess: a) ease of use and b) whether test data could clearly and accurately depict the well-known dose-response relationship between light intensity and pupil contraction. A total of 822 videos were collected. We used an open source video analysis software to measure pupil size in pixel units. Pupillary responsiveness was expressed as the percent change in pupil size from pre- to post-light exposure. Box plots, t test, and multi-level mixed effects linear regression modeling were used to characterize the relationship between light intensity and pupillary response. RESULTS: The PFDA was employed with only minor technical challenges in Bangladesh, Kenya, Zambia, and Peru. Our data show a clear linear increase in pupillary constriction with increasing log light intensity. Light intensity was a strong predictor of pupillary response, regardless of baseline pupil size. CONCLUSIONS: The consistent physiological response demonstrated here supports the use of the PFDA as a reliable tool to measure dark adaptation. As a next step, PFDA measurements will be validated against biochemical indicators of vitamin A status and hypoxemia. Ultimately, this new technology may provide a novel approach for nutritional assessment, with potential clinical applications. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12886-015-0062-7) contains supplementary material, which is available to authorized users. BioMed Central 2015-07-09 /pmc/articles/PMC4496941/ /pubmed/26156587 http://dx.doi.org/10.1186/s12886-015-0062-7 Text en © Labrique et al. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Technical Advance Labrique, Alain B. Palmer, Amanda C. Healy, Katherine Mehra, Sucheta Sauer, Theodor C. West, Keith P. Sommer, Alfred A novel device for assessing dark adaptation in field settings |
title | A novel device for assessing dark adaptation in field settings |
title_full | A novel device for assessing dark adaptation in field settings |
title_fullStr | A novel device for assessing dark adaptation in field settings |
title_full_unstemmed | A novel device for assessing dark adaptation in field settings |
title_short | A novel device for assessing dark adaptation in field settings |
title_sort | novel device for assessing dark adaptation in field settings |
topic | Technical Advance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4496941/ https://www.ncbi.nlm.nih.gov/pubmed/26156587 http://dx.doi.org/10.1186/s12886-015-0062-7 |
work_keys_str_mv | AT labriquealainb anoveldeviceforassessingdarkadaptationinfieldsettings AT palmeramandac anoveldeviceforassessingdarkadaptationinfieldsettings AT healykatherine anoveldeviceforassessingdarkadaptationinfieldsettings AT mehrasucheta anoveldeviceforassessingdarkadaptationinfieldsettings AT sauertheodorc anoveldeviceforassessingdarkadaptationinfieldsettings AT westkeithp anoveldeviceforassessingdarkadaptationinfieldsettings AT sommeralfred anoveldeviceforassessingdarkadaptationinfieldsettings AT labriquealainb noveldeviceforassessingdarkadaptationinfieldsettings AT palmeramandac noveldeviceforassessingdarkadaptationinfieldsettings AT healykatherine noveldeviceforassessingdarkadaptationinfieldsettings AT mehrasucheta noveldeviceforassessingdarkadaptationinfieldsettings AT sauertheodorc noveldeviceforassessingdarkadaptationinfieldsettings AT westkeithp noveldeviceforassessingdarkadaptationinfieldsettings AT sommeralfred noveldeviceforassessingdarkadaptationinfieldsettings |