Cargando…

Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy

The aim of this study was to compare lateral photon–electron (LPE), helical tomotherapy (HT), and volumetric-modulated arc therapy (VMAT) plans for total scalp irradiation. We selected a single adult model case and compared the dosimetric results for the three plans. All plans mainly used 6-MV photo...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Jin Ho, Jung, Ji-Young, Park, Hyung-Wook, Lee, Gi Woong, Chae, Soo-Min, Kay, Chul Seung, SON, Seok Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4497384/
https://www.ncbi.nlm.nih.gov/pubmed/24927727
http://dx.doi.org/10.1093/jrr/rru049
_version_ 1782380506902429696
author Song, Jin Ho
Jung, Ji-Young
Park, Hyung-Wook
Lee, Gi Woong
Chae, Soo-Min
Kay, Chul Seung
SON, Seok Hyun
author_facet Song, Jin Ho
Jung, Ji-Young
Park, Hyung-Wook
Lee, Gi Woong
Chae, Soo-Min
Kay, Chul Seung
SON, Seok Hyun
author_sort Song, Jin Ho
collection PubMed
description The aim of this study was to compare lateral photon–electron (LPE), helical tomotherapy (HT), and volumetric-modulated arc therapy (VMAT) plans for total scalp irradiation. We selected a single adult model case and compared the dosimetric results for the three plans. All plans mainly used 6-MV photon beams, and the prescription dose was 60 Gy in 30 fractions. First, we compared the LPE, HT and VMAT plans, with all plans including a 1-cm bolus. We also compared HT plans with and without the bolus. The conformity indices for LPE, HT and VMAT were 1.73, 1.35 and 1.49, respectively. The HT plan showed the best conformity and the LPE plan showed the worst. However, the plans had similar homogeneity indexes. The dose to the hippocampus was the highest in the VMAT plan, with a mean of 6.7 Gy, compared with 3.5 Gy in the LPE plan and 4.8 Gy in the HT plan. The doses to the optical structures were all within the clinically acceptable range. The beam-on time and monitor units were highest in the HT plan. The HT plans with and without a bolus showed similar target coverage and organ-at-risk (OAR) sparing. The HT plan showed the best target coverage and conformity, with low doses to the brain and hippocampus. This plan also had the advantage of not necessarily requiring a bolus. Although the VMAT plan showed better conformity than the LPE plan and acceptable OAR sparing, the dose to the hippocampus should be considered when high doses are prescribed.
format Online
Article
Text
id pubmed-4497384
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-44973842015-07-10 Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy Song, Jin Ho Jung, Ji-Young Park, Hyung-Wook Lee, Gi Woong Chae, Soo-Min Kay, Chul Seung SON, Seok Hyun J Radiat Res Oncology The aim of this study was to compare lateral photon–electron (LPE), helical tomotherapy (HT), and volumetric-modulated arc therapy (VMAT) plans for total scalp irradiation. We selected a single adult model case and compared the dosimetric results for the three plans. All plans mainly used 6-MV photon beams, and the prescription dose was 60 Gy in 30 fractions. First, we compared the LPE, HT and VMAT plans, with all plans including a 1-cm bolus. We also compared HT plans with and without the bolus. The conformity indices for LPE, HT and VMAT were 1.73, 1.35 and 1.49, respectively. The HT plan showed the best conformity and the LPE plan showed the worst. However, the plans had similar homogeneity indexes. The dose to the hippocampus was the highest in the VMAT plan, with a mean of 6.7 Gy, compared with 3.5 Gy in the LPE plan and 4.8 Gy in the HT plan. The doses to the optical structures were all within the clinically acceptable range. The beam-on time and monitor units were highest in the HT plan. The HT plans with and without a bolus showed similar target coverage and organ-at-risk (OAR) sparing. The HT plan showed the best target coverage and conformity, with low doses to the brain and hippocampus. This plan also had the advantage of not necessarily requiring a bolus. Although the VMAT plan showed better conformity than the LPE plan and acceptable OAR sparing, the dose to the hippocampus should be considered when high doses are prescribed. Oxford University Press 2015-07 2014-06-13 /pmc/articles/PMC4497384/ /pubmed/24927727 http://dx.doi.org/10.1093/jrr/rru049 Text en © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Oncology
Song, Jin Ho
Jung, Ji-Young
Park, Hyung-Wook
Lee, Gi Woong
Chae, Soo-Min
Kay, Chul Seung
SON, Seok Hyun
Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy
title Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy
title_full Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy
title_fullStr Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy
title_full_unstemmed Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy
title_short Dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy
title_sort dosimetric comparison of three different treatment modalities for total scalp irradiation: the conventional lateral photon–electron technique, helical tomotherapy, and volumetric-modulated arc therapy
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4497384/
https://www.ncbi.nlm.nih.gov/pubmed/24927727
http://dx.doi.org/10.1093/jrr/rru049
work_keys_str_mv AT songjinho dosimetriccomparisonofthreedifferenttreatmentmodalitiesfortotalscalpirradiationtheconventionallateralphotonelectrontechniquehelicaltomotherapyandvolumetricmodulatedarctherapy
AT jungjiyoung dosimetriccomparisonofthreedifferenttreatmentmodalitiesfortotalscalpirradiationtheconventionallateralphotonelectrontechniquehelicaltomotherapyandvolumetricmodulatedarctherapy
AT parkhyungwook dosimetriccomparisonofthreedifferenttreatmentmodalitiesfortotalscalpirradiationtheconventionallateralphotonelectrontechniquehelicaltomotherapyandvolumetricmodulatedarctherapy
AT leegiwoong dosimetriccomparisonofthreedifferenttreatmentmodalitiesfortotalscalpirradiationtheconventionallateralphotonelectrontechniquehelicaltomotherapyandvolumetricmodulatedarctherapy
AT chaesoomin dosimetriccomparisonofthreedifferenttreatmentmodalitiesfortotalscalpirradiationtheconventionallateralphotonelectrontechniquehelicaltomotherapyandvolumetricmodulatedarctherapy
AT kaychulseung dosimetriccomparisonofthreedifferenttreatmentmodalitiesfortotalscalpirradiationtheconventionallateralphotonelectrontechniquehelicaltomotherapyandvolumetricmodulatedarctherapy
AT sonseokhyun dosimetriccomparisonofthreedifferenttreatmentmodalitiesfortotalscalpirradiationtheconventionallateralphotonelectrontechniquehelicaltomotherapyandvolumetricmodulatedarctherapy