Cargando…
Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts
Cardiac tissue engineering is a promising approach to provide large-scale tissues for transplantation to regenerate the heart after ischemic injury, however, integration with the host myocardium will be required to achieve electromechanical benefits. To test the ability of engineered heart tissues t...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4498815/ https://www.ncbi.nlm.nih.gov/pubmed/26161513 http://dx.doi.org/10.1371/journal.pone.0131446 |
_version_ | 1782380684581535744 |
---|---|
author | Gerbin, Kaytlyn A. Yang, Xiulan Murry, Charles E. Coulombe, Kareen L. K. |
author_facet | Gerbin, Kaytlyn A. Yang, Xiulan Murry, Charles E. Coulombe, Kareen L. K. |
author_sort | Gerbin, Kaytlyn A. |
collection | PubMed |
description | Cardiac tissue engineering is a promising approach to provide large-scale tissues for transplantation to regenerate the heart after ischemic injury, however, integration with the host myocardium will be required to achieve electromechanical benefits. To test the ability of engineered heart tissues to electrically integrate with the host, 10 million human embryonic stem cell (hESC)-derived cardiomyocytes were used to form either scaffold-free tissue patches implanted on the epicardium or micro-tissue particles (~1000 cells/particle) delivered by intramyocardial injection into the left ventricular wall of the ischemia/reperfusion injured athymic rat heart. Results were compared to intramyocardial injection of 10 million dispersed hESC-cardiomyocytes. Graft size was not significantly different between treatment groups and correlated inversely with infarct size. After implantation on the epicardial surface, hESC-cardiac tissue patches were electromechanically active, but they beat slowly and were not electrically coupled to the host at 4 weeks based on ex vivo fluorescent imaging of their graft-autonomous GCaMP3 calcium reporter. Histologically, scar tissue physically separated the patch graft and host myocardium. In contrast, following intramyocardial injection of micro-tissue particles and suspended cardiomyocytes, 100% of the grafts detected by fluorescent GCaMP3 imaging were electrically coupled to the host heart at spontaneous rate and could follow host pacing up to a maximum of 300–390 beats per minute (5–6.5 Hz). Gap junctions between intramyocardial graft and host tissue were identified histologically. The extensive coupling and rapid response rate of the human myocardial grafts after intramyocardial delivery suggest electrophysiological adaptation of hESC-derived cardiomyocytes to the rat heart’s pacemaking activity. These data support the use of the rat model for studying electromechanical integration of human cardiomyocytes, and they identify lack of electrical integration as a challenge to overcome in tissue engineered patches. |
format | Online Article Text |
id | pubmed-4498815 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-44988152015-07-17 Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts Gerbin, Kaytlyn A. Yang, Xiulan Murry, Charles E. Coulombe, Kareen L. K. PLoS One Research Article Cardiac tissue engineering is a promising approach to provide large-scale tissues for transplantation to regenerate the heart after ischemic injury, however, integration with the host myocardium will be required to achieve electromechanical benefits. To test the ability of engineered heart tissues to electrically integrate with the host, 10 million human embryonic stem cell (hESC)-derived cardiomyocytes were used to form either scaffold-free tissue patches implanted on the epicardium or micro-tissue particles (~1000 cells/particle) delivered by intramyocardial injection into the left ventricular wall of the ischemia/reperfusion injured athymic rat heart. Results were compared to intramyocardial injection of 10 million dispersed hESC-cardiomyocytes. Graft size was not significantly different between treatment groups and correlated inversely with infarct size. After implantation on the epicardial surface, hESC-cardiac tissue patches were electromechanically active, but they beat slowly and were not electrically coupled to the host at 4 weeks based on ex vivo fluorescent imaging of their graft-autonomous GCaMP3 calcium reporter. Histologically, scar tissue physically separated the patch graft and host myocardium. In contrast, following intramyocardial injection of micro-tissue particles and suspended cardiomyocytes, 100% of the grafts detected by fluorescent GCaMP3 imaging were electrically coupled to the host heart at spontaneous rate and could follow host pacing up to a maximum of 300–390 beats per minute (5–6.5 Hz). Gap junctions between intramyocardial graft and host tissue were identified histologically. The extensive coupling and rapid response rate of the human myocardial grafts after intramyocardial delivery suggest electrophysiological adaptation of hESC-derived cardiomyocytes to the rat heart’s pacemaking activity. These data support the use of the rat model for studying electromechanical integration of human cardiomyocytes, and they identify lack of electrical integration as a challenge to overcome in tissue engineered patches. Public Library of Science 2015-07-10 /pmc/articles/PMC4498815/ /pubmed/26161513 http://dx.doi.org/10.1371/journal.pone.0131446 Text en © 2015 Gerbin et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Gerbin, Kaytlyn A. Yang, Xiulan Murry, Charles E. Coulombe, Kareen L. K. Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts |
title | Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts |
title_full | Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts |
title_fullStr | Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts |
title_full_unstemmed | Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts |
title_short | Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts |
title_sort | enhanced electrical integration of engineered human myocardium via intramyocardial versus epicardial delivery in infarcted rat hearts |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4498815/ https://www.ncbi.nlm.nih.gov/pubmed/26161513 http://dx.doi.org/10.1371/journal.pone.0131446 |
work_keys_str_mv | AT gerbinkaytlyna enhancedelectricalintegrationofengineeredhumanmyocardiumviaintramyocardialversusepicardialdeliveryininfarctedrathearts AT yangxiulan enhancedelectricalintegrationofengineeredhumanmyocardiumviaintramyocardialversusepicardialdeliveryininfarctedrathearts AT murrycharlese enhancedelectricalintegrationofengineeredhumanmyocardiumviaintramyocardialversusepicardialdeliveryininfarctedrathearts AT coulombekareenlk enhancedelectricalintegrationofengineeredhumanmyocardiumviaintramyocardialversusepicardialdeliveryininfarctedrathearts |