Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography

Objective. The aim of this work was to develop a fast and robust (semi)automatic segmentation technique of the aortic valve area (AVA) MDCT datasets. Methods. The algorithm starts with detection and cropping of Sinus of Valsalva on MPR image. The cropped image is then binarized and seed points are m...

Descripción completa

Detalles Bibliográficos
Autores principales: Tuncay, V., Prakken, N., van Ooijen, P. M. A., Budde, R. P. J., Leiner, T., Oudkerk, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4499628/
https://www.ncbi.nlm.nih.gov/pubmed/26221603
http://dx.doi.org/10.1155/2015/648283
_version_ 1782380817228496896
author Tuncay, V.
Prakken, N.
van Ooijen, P. M. A.
Budde, R. P. J.
Leiner, T.
Oudkerk, M.
author_facet Tuncay, V.
Prakken, N.
van Ooijen, P. M. A.
Budde, R. P. J.
Leiner, T.
Oudkerk, M.
author_sort Tuncay, V.
collection PubMed
description Objective. The aim of this work was to develop a fast and robust (semi)automatic segmentation technique of the aortic valve area (AVA) MDCT datasets. Methods. The algorithm starts with detection and cropping of Sinus of Valsalva on MPR image. The cropped image is then binarized and seed points are manually selected to create an initial contour. The contour moves automatically towards the edge of aortic AVA to obtain a segmentation of the AVA. AVA was segmented semiautomatically and manually by two observers in multiphase cardiac CT scans of 25 patients. Validation of the algorithm was obtained by comparing to Transthoracic Echocardiography (TTE). Intra- and interobserver variability were calculated by relative differences. Differences between TTE and MDCT manual and semiautomatic measurements were assessed by Bland-Altman analysis. Time required for manual and semiautomatic segmentations was recorded. Results. Mean differences from TTE were −0.19 (95% CI: −0.74 to 0.34) cm(2) for manual and −0.10 (95% CI: −0.45 to 0.25) cm(2) for semiautomatic measurements. Intra- and interobserver variability were 8.4 ± 7.1% and 27.6 ± 16.0% for manual, and 5.8 ± 4.5% and 16.8 ± 12.7% for semiautomatic measurements, respectively. Conclusion. Newly developed semiautomatic segmentation provides an accurate, more reproducible, and faster AVA segmentation result.
format Online
Article
Text
id pubmed-4499628
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-44996282015-07-28 Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography Tuncay, V. Prakken, N. van Ooijen, P. M. A. Budde, R. P. J. Leiner, T. Oudkerk, M. Biomed Res Int Research Article Objective. The aim of this work was to develop a fast and robust (semi)automatic segmentation technique of the aortic valve area (AVA) MDCT datasets. Methods. The algorithm starts with detection and cropping of Sinus of Valsalva on MPR image. The cropped image is then binarized and seed points are manually selected to create an initial contour. The contour moves automatically towards the edge of aortic AVA to obtain a segmentation of the AVA. AVA was segmented semiautomatically and manually by two observers in multiphase cardiac CT scans of 25 patients. Validation of the algorithm was obtained by comparing to Transthoracic Echocardiography (TTE). Intra- and interobserver variability were calculated by relative differences. Differences between TTE and MDCT manual and semiautomatic measurements were assessed by Bland-Altman analysis. Time required for manual and semiautomatic segmentations was recorded. Results. Mean differences from TTE were −0.19 (95% CI: −0.74 to 0.34) cm(2) for manual and −0.10 (95% CI: −0.45 to 0.25) cm(2) for semiautomatic measurements. Intra- and interobserver variability were 8.4 ± 7.1% and 27.6 ± 16.0% for manual, and 5.8 ± 4.5% and 16.8 ± 12.7% for semiautomatic measurements, respectively. Conclusion. Newly developed semiautomatic segmentation provides an accurate, more reproducible, and faster AVA segmentation result. Hindawi Publishing Corporation 2015 2015-06-29 /pmc/articles/PMC4499628/ /pubmed/26221603 http://dx.doi.org/10.1155/2015/648283 Text en Copyright © 2015 V. Tuncay et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Tuncay, V.
Prakken, N.
van Ooijen, P. M. A.
Budde, R. P. J.
Leiner, T.
Oudkerk, M.
Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography
title Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography
title_full Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography
title_fullStr Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography
title_full_unstemmed Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography
title_short Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography
title_sort semiautomatic, quantitative measurement of aortic valve area using cta: validation and comparison with transthoracic echocardiography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4499628/
https://www.ncbi.nlm.nih.gov/pubmed/26221603
http://dx.doi.org/10.1155/2015/648283
work_keys_str_mv AT tuncayv semiautomaticquantitativemeasurementofaorticvalveareausingctavalidationandcomparisonwithtransthoracicechocardiography
AT prakkenn semiautomaticquantitativemeasurementofaorticvalveareausingctavalidationandcomparisonwithtransthoracicechocardiography
AT vanooijenpma semiautomaticquantitativemeasurementofaorticvalveareausingctavalidationandcomparisonwithtransthoracicechocardiography
AT budderpj semiautomaticquantitativemeasurementofaorticvalveareausingctavalidationandcomparisonwithtransthoracicechocardiography
AT leinert semiautomaticquantitativemeasurementofaorticvalveareausingctavalidationandcomparisonwithtransthoracicechocardiography
AT oudkerkm semiautomaticquantitativemeasurementofaorticvalveareausingctavalidationandcomparisonwithtransthoracicechocardiography