Cargando…
The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases
INTRODUCTION: Scaphoid fracture is the most common fracture among the bones of the wrist. Plain radiography has a sensitivity of 59 to 79 percent for the diagnosis of scaphoid fracture after injury. Casting is done to avoid complications in patients with suspected fractures with normal radiography....
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AVICENA, d.o.o., Sarajevo
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4500294/ https://www.ncbi.nlm.nih.gov/pubmed/26261383 http://dx.doi.org/10.5455/medarh.2015.69.161-164 |
_version_ | 1782380896502939648 |
---|---|
author | Sharifi, Mohammad Davood Moghaddam, Hamid Zamani Zakeri, Hosein Ebrahimi, Mohsen Saeedian, Hesamoddin Hashemian, Amir Masoud |
author_facet | Sharifi, Mohammad Davood Moghaddam, Hamid Zamani Zakeri, Hosein Ebrahimi, Mohsen Saeedian, Hesamoddin Hashemian, Amir Masoud |
author_sort | Sharifi, Mohammad Davood |
collection | PubMed |
description | INTRODUCTION: Scaphoid fracture is the most common fracture among the bones of the wrist. Plain radiography has a sensitivity of 59 to 79 percent for the diagnosis of scaphoid fracture after injury. Casting is done to avoid complications in patients with suspected fractures with normal radiography. Magnetic resonance imaging (MRI) has a sensitivity of 100% and a specificity of 99%. To avoid unnecessary casting and high costs, we decided to offer a way more efficient than radiography and less costly than MRI. MATERIAL AND METHODS: In the present study, 175 patients with suspected scaphoid fracture along with snuff box tenderness and normal radiography were enrolled in the study. On arrival, patients’ pain score were determined using visual analog scale method with anatomical snuffbox tenderness and then MRI was performed on the patients’ wrist and the results were recorded for patient in the check list. The data was then aggregated and analyzed. RESULTS: The result of MRI for fracture was negative for 90.9% and positive for 9.1%. The mean pain score was 7.3 in negative MRI group and 8.75 in positive MRI group, considering a significant difference. ROC curve graph showed that the sensitivity and specificity will be 87% and 57%, respectively for scores 7.5 and higher and 75% and 72%, respectively for scores 8.5 and higher. CONCLUSION: It seems that although this method, beside other criteria in the diagnosis of fractures, can be useful in future studies, it would not be helpful in fracture detection. |
format | Online Article Text |
id | pubmed-4500294 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | AVICENA, d.o.o., Sarajevo |
record_format | MEDLINE/PubMed |
spelling | pubmed-45002942015-08-10 The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases Sharifi, Mohammad Davood Moghaddam, Hamid Zamani Zakeri, Hosein Ebrahimi, Mohsen Saeedian, Hesamoddin Hashemian, Amir Masoud Med Arch Original Paper INTRODUCTION: Scaphoid fracture is the most common fracture among the bones of the wrist. Plain radiography has a sensitivity of 59 to 79 percent for the diagnosis of scaphoid fracture after injury. Casting is done to avoid complications in patients with suspected fractures with normal radiography. Magnetic resonance imaging (MRI) has a sensitivity of 100% and a specificity of 99%. To avoid unnecessary casting and high costs, we decided to offer a way more efficient than radiography and less costly than MRI. MATERIAL AND METHODS: In the present study, 175 patients with suspected scaphoid fracture along with snuff box tenderness and normal radiography were enrolled in the study. On arrival, patients’ pain score were determined using visual analog scale method with anatomical snuffbox tenderness and then MRI was performed on the patients’ wrist and the results were recorded for patient in the check list. The data was then aggregated and analyzed. RESULTS: The result of MRI for fracture was negative for 90.9% and positive for 9.1%. The mean pain score was 7.3 in negative MRI group and 8.75 in positive MRI group, considering a significant difference. ROC curve graph showed that the sensitivity and specificity will be 87% and 57%, respectively for scores 7.5 and higher and 75% and 72%, respectively for scores 8.5 and higher. CONCLUSION: It seems that although this method, beside other criteria in the diagnosis of fractures, can be useful in future studies, it would not be helpful in fracture detection. AVICENA, d.o.o., Sarajevo 2015-06 2015-06-10 /pmc/articles/PMC4500294/ /pubmed/26261383 http://dx.doi.org/10.5455/medarh.2015.69.161-164 Text en Copyright: © Mohammad Davood Sharifi, Hamid Zamani Moghaddam, Hosein Zakeri, Mohsen Ebrahimi, Hesamoddin Saeedian, Amir Masoud Hashemian http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Sharifi, Mohammad Davood Moghaddam, Hamid Zamani Zakeri, Hosein Ebrahimi, Mohsen Saeedian, Hesamoddin Hashemian, Amir Masoud The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases |
title | The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases |
title_full | The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases |
title_fullStr | The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases |
title_full_unstemmed | The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases |
title_short | The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases |
title_sort | accuracy of pain measurement in diagnosis of scaphoid bone fractures in patients with magnetic resonance imaging: report of 175 cases |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4500294/ https://www.ncbi.nlm.nih.gov/pubmed/26261383 http://dx.doi.org/10.5455/medarh.2015.69.161-164 |
work_keys_str_mv | AT sharifimohammaddavood theaccuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT moghaddamhamidzamani theaccuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT zakerihosein theaccuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT ebrahimimohsen theaccuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT saeedianhesamoddin theaccuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT hashemianamirmasoud theaccuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT sharifimohammaddavood accuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT moghaddamhamidzamani accuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT zakerihosein accuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT ebrahimimohsen accuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT saeedianhesamoddin accuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases AT hashemianamirmasoud accuracyofpainmeasurementindiagnosisofscaphoidbonefracturesinpatientswithmagneticresonanceimagingreportof175cases |