Cargando…

Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography

To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Xing, Yan, Azati, Gulina, Pan, Cun-xue, Dang, Jun, Jha, Sailendra, Liu, Wen-ya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4500390/
https://www.ncbi.nlm.nih.gov/pubmed/26167680
http://dx.doi.org/10.1371/journal.pone.0132412
_version_ 1782380901839142912
author Xing, Yan
Azati, Gulina
Pan, Cun-xue
Dang, Jun
Jha, Sailendra
Liu, Wen-ya
author_facet Xing, Yan
Azati, Gulina
Pan, Cun-xue
Dang, Jun
Jha, Sailendra
Liu, Wen-ya
author_sort Xing, Yan
collection PubMed
description To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients who underwent CCTA were prospectively randomized into two groups. Group A (n = 80) used individualized-protocol with adjusted injection rate based on patient weight and contrast medium concentration to obtain constant iodine load of 280 mgI/kg while group B (n = 80) followed the conventional contrast injection protocol with total injection volume of 80ml and constant injection rate of 5.5ml/s. For both groups, patients were further divided into four subgroups with different CM concentrations: A1, B1 (300 mg I/ml); A2, B2 (320 mg I/ml); A3, B3 (350 mg I/ml) and A4 and B4 (370 mg I/ml). For each patient, the CT values of the ascending aorta, left ventricle and coronary arteries were measured. One-way analysis of variance was used to compare CT values among subgroups. Among the subgroups of A, sufficient attenuation of greater than 300HU was obtained in all target vessels with no difference among them. Among the subgroups of B, the CT values had significant difference in left ventricle, left circumflex branch, proximal and distal segment of the right coronary artery (all p < 0.05), and the attenuation with 300 mg I/ml CM concentration was significantly lower than that with 370 mg I/ml. Compared with group B, group A used less volume (62.83 ml vs. 80.00 ml, P<0.001) and lower rate (5.21 ml/s vs. 5.50 ml/s, P<0.001) of CM. Compared with the conventional contrast medium injection protocol with fixed volume and injection rate, the individualized-protocol based on patient weight and contrast concentration provides overall contrast dose reduction and achieves more homogenous attenuation among different coronary vessels and patients.
format Online
Article
Text
id pubmed-4500390
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45003902015-07-17 Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography Xing, Yan Azati, Gulina Pan, Cun-xue Dang, Jun Jha, Sailendra Liu, Wen-ya PLoS One Research Article To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients who underwent CCTA were prospectively randomized into two groups. Group A (n = 80) used individualized-protocol with adjusted injection rate based on patient weight and contrast medium concentration to obtain constant iodine load of 280 mgI/kg while group B (n = 80) followed the conventional contrast injection protocol with total injection volume of 80ml and constant injection rate of 5.5ml/s. For both groups, patients were further divided into four subgroups with different CM concentrations: A1, B1 (300 mg I/ml); A2, B2 (320 mg I/ml); A3, B3 (350 mg I/ml) and A4 and B4 (370 mg I/ml). For each patient, the CT values of the ascending aorta, left ventricle and coronary arteries were measured. One-way analysis of variance was used to compare CT values among subgroups. Among the subgroups of A, sufficient attenuation of greater than 300HU was obtained in all target vessels with no difference among them. Among the subgroups of B, the CT values had significant difference in left ventricle, left circumflex branch, proximal and distal segment of the right coronary artery (all p < 0.05), and the attenuation with 300 mg I/ml CM concentration was significantly lower than that with 370 mg I/ml. Compared with group B, group A used less volume (62.83 ml vs. 80.00 ml, P<0.001) and lower rate (5.21 ml/s vs. 5.50 ml/s, P<0.001) of CM. Compared with the conventional contrast medium injection protocol with fixed volume and injection rate, the individualized-protocol based on patient weight and contrast concentration provides overall contrast dose reduction and achieves more homogenous attenuation among different coronary vessels and patients. Public Library of Science 2015-07-13 /pmc/articles/PMC4500390/ /pubmed/26167680 http://dx.doi.org/10.1371/journal.pone.0132412 Text en © 2015 Xing et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Xing, Yan
Azati, Gulina
Pan, Cun-xue
Dang, Jun
Jha, Sailendra
Liu, Wen-ya
Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography
title Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography
title_full Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography
title_fullStr Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography
title_full_unstemmed Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography
title_short Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography
title_sort improving patient to patient ct value uniformity with an individualized contrast medium protocol tailored to body weight and contrast medium concentration in coronary ct angiography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4500390/
https://www.ncbi.nlm.nih.gov/pubmed/26167680
http://dx.doi.org/10.1371/journal.pone.0132412
work_keys_str_mv AT xingyan improvingpatienttopatientctvalueuniformitywithanindividualizedcontrastmediumprotocoltailoredtobodyweightandcontrastmediumconcentrationincoronaryctangiography
AT azatigulina improvingpatienttopatientctvalueuniformitywithanindividualizedcontrastmediumprotocoltailoredtobodyweightandcontrastmediumconcentrationincoronaryctangiography
AT pancunxue improvingpatienttopatientctvalueuniformitywithanindividualizedcontrastmediumprotocoltailoredtobodyweightandcontrastmediumconcentrationincoronaryctangiography
AT dangjun improvingpatienttopatientctvalueuniformitywithanindividualizedcontrastmediumprotocoltailoredtobodyweightandcontrastmediumconcentrationincoronaryctangiography
AT jhasailendra improvingpatienttopatientctvalueuniformitywithanindividualizedcontrastmediumprotocoltailoredtobodyweightandcontrastmediumconcentrationincoronaryctangiography
AT liuwenya improvingpatienttopatientctvalueuniformitywithanindividualizedcontrastmediumprotocoltailoredtobodyweightandcontrastmediumconcentrationincoronaryctangiography