Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography

PURPOSE: To evaluate and investigate the distribution and repeatability of anterior corneal surface astigmatism measurements (axis and magnitude) using a novel corneal topographer. METHODS: Anterior corneal surface astigmatism was investigated in a total of 195 eyes using a novel multicolored spot r...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanellopoulos, Anastasios John, Asimellis, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cornea 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4500657/
https://www.ncbi.nlm.nih.gov/pubmed/26057324
http://dx.doi.org/10.1097/ICO.0000000000000476
_version_ 1782380949368995840
author Kanellopoulos, Anastasios John
Asimellis, George
author_facet Kanellopoulos, Anastasios John
Asimellis, George
author_sort Kanellopoulos, Anastasios John
collection PubMed
description PURPOSE: To evaluate and investigate the distribution and repeatability of anterior corneal surface astigmatism measurements (axis and magnitude) using a novel corneal topographer. METHODS: Anterior corneal surface astigmatism was investigated in a total of 195 eyes using a novel multicolored spot reflection topographer (Cassini; i-Optics). Two patient groups were studied, a younger-age group A and an older-age group B. Three consecutive acquisitions were obtained from each eye. The repeatability of measurement was assessed using Bland–Altman plot analysis and is reported as the coefficient of repeatability. RESULTS: Group A (average age 34.3 years) had on average with-the-rule astigmatism, whereas the older-age group B (average age 72.3 years) had on average against-the-rule astigmatism. Average astigmatism magnitude measurement repeatability in group A was 0.4 diopters (D) and in group B 0.4 D. Average astigmatism axis measurement repeatability in group A was 5.4 degrees and in group B 5.5 degrees. The axis measurement repeatability improved with increasing magnitude of astigmatism: in the subgroups with astigmatism between 3.0 and 6.0 D, the axis repeatability was 1.4 degrees (group A) and 1.2 degrees (group B), whereas in the subgroups with astigmatism larger than 6.0 D, the repeatability was 1.1 and 0.6 degrees, respectively. CONCLUSIONS: This novel corneal topography device seems to offer high precision in reporting corneal astigmatism. This study reaffirms the established trend of a corneal astigmatism shift from an average “with-the-rule” to “against-the-rule” with aging.
format Online
Article
Text
id pubmed-4500657
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Cornea
record_format MEDLINE/PubMed
spelling pubmed-45006572015-07-17 Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography Kanellopoulos, Anastasios John Asimellis, George Cornea Basic Investigation PURPOSE: To evaluate and investigate the distribution and repeatability of anterior corneal surface astigmatism measurements (axis and magnitude) using a novel corneal topographer. METHODS: Anterior corneal surface astigmatism was investigated in a total of 195 eyes using a novel multicolored spot reflection topographer (Cassini; i-Optics). Two patient groups were studied, a younger-age group A and an older-age group B. Three consecutive acquisitions were obtained from each eye. The repeatability of measurement was assessed using Bland–Altman plot analysis and is reported as the coefficient of repeatability. RESULTS: Group A (average age 34.3 years) had on average with-the-rule astigmatism, whereas the older-age group B (average age 72.3 years) had on average against-the-rule astigmatism. Average astigmatism magnitude measurement repeatability in group A was 0.4 diopters (D) and in group B 0.4 D. Average astigmatism axis measurement repeatability in group A was 5.4 degrees and in group B 5.5 degrees. The axis measurement repeatability improved with increasing magnitude of astigmatism: in the subgroups with astigmatism between 3.0 and 6.0 D, the axis repeatability was 1.4 degrees (group A) and 1.2 degrees (group B), whereas in the subgroups with astigmatism larger than 6.0 D, the repeatability was 1.1 and 0.6 degrees, respectively. CONCLUSIONS: This novel corneal topography device seems to offer high precision in reporting corneal astigmatism. This study reaffirms the established trend of a corneal astigmatism shift from an average “with-the-rule” to “against-the-rule” with aging. Cornea 2015-06-09 2015-08 /pmc/articles/PMC4500657/ /pubmed/26057324 http://dx.doi.org/10.1097/ICO.0000000000000476 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License, where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.
spellingShingle Basic Investigation
Kanellopoulos, Anastasios John
Asimellis, George
Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography
title Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography
title_full Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography
title_fullStr Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography
title_full_unstemmed Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography
title_short Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography
title_sort distribution and repeatability of corneal astigmatism measurements (magnitude and axis) evaluated with color light emitting diode reflection topography
topic Basic Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4500657/
https://www.ncbi.nlm.nih.gov/pubmed/26057324
http://dx.doi.org/10.1097/ICO.0000000000000476
work_keys_str_mv AT kanellopoulosanastasiosjohn distributionandrepeatabilityofcornealastigmatismmeasurementsmagnitudeandaxisevaluatedwithcolorlightemittingdiodereflectiontopography
AT asimellisgeorge distributionandrepeatabilityofcornealastigmatismmeasurementsmagnitudeandaxisevaluatedwithcolorlightemittingdiodereflectiontopography