Cargando…

Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study

OBJECTIVE: The aim of this study was to compare the fit accuracies of metal partial removable dental prosthesis (PRDP) frameworks fabricated by the traditional technique (TT) or the light-curing modeling material technique (LCMT). MATERIALS AND METHODS: A metal model of a Kennedy class III modificat...

Descripción completa

Detalles Bibliográficos
Autores principales: Anan, Mohammad Tarek M., Al-Saadi, Mohannad H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4501440/
https://www.ncbi.nlm.nih.gov/pubmed/26236129
http://dx.doi.org/10.1016/j.sdentj.2014.11.013
_version_ 1782381069904904192
author Anan, Mohammad Tarek M.
Al-Saadi, Mohannad H.
author_facet Anan, Mohammad Tarek M.
Al-Saadi, Mohannad H.
author_sort Anan, Mohammad Tarek M.
collection PubMed
description OBJECTIVE: The aim of this study was to compare the fit accuracies of metal partial removable dental prosthesis (PRDP) frameworks fabricated by the traditional technique (TT) or the light-curing modeling material technique (LCMT). MATERIALS AND METHODS: A metal model of a Kennedy class III modification 1 mandibular dental arch with two edentulous spaces of different spans, short and long, was used for the study. Thirty identical working casts were used to produce 15 PRDP frameworks each by TT and by LCMT. Every framework was transferred to a metal master cast to measure the gap between the metal base of the framework and the crest of the alveolar ridge of the cast. Gaps were measured at three points on each side by a USB digital intraoral camera at ×16.5 magnification. Images were transferred to a graphics editing program. A single examiner performed all measurements. The two-tailed t-test was performed at the 5% significance level. RESULTS: The mean gap value was significantly smaller in the LCMT group compared to the TT group. The mean value of the short edentulous span was significantly smaller than that of the long edentulous span in the LCMT group, whereas the opposite result was obtained in the TT group. CONCLUSION: Within the limitations of this study, it can be concluded that the fit of the LCMT-fabricated frameworks was better than the fit of the TT-fabricated frameworks. The framework fit can differ according to the span of the edentate ridge and the fabrication technique for the metal framework.
format Online
Article
Text
id pubmed-4501440
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-45014402015-08-01 Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study Anan, Mohammad Tarek M. Al-Saadi, Mohannad H. Saudi Dent J Original Article OBJECTIVE: The aim of this study was to compare the fit accuracies of metal partial removable dental prosthesis (PRDP) frameworks fabricated by the traditional technique (TT) or the light-curing modeling material technique (LCMT). MATERIALS AND METHODS: A metal model of a Kennedy class III modification 1 mandibular dental arch with two edentulous spaces of different spans, short and long, was used for the study. Thirty identical working casts were used to produce 15 PRDP frameworks each by TT and by LCMT. Every framework was transferred to a metal master cast to measure the gap between the metal base of the framework and the crest of the alveolar ridge of the cast. Gaps were measured at three points on each side by a USB digital intraoral camera at ×16.5 magnification. Images were transferred to a graphics editing program. A single examiner performed all measurements. The two-tailed t-test was performed at the 5% significance level. RESULTS: The mean gap value was significantly smaller in the LCMT group compared to the TT group. The mean value of the short edentulous span was significantly smaller than that of the long edentulous span in the LCMT group, whereas the opposite result was obtained in the TT group. CONCLUSION: Within the limitations of this study, it can be concluded that the fit of the LCMT-fabricated frameworks was better than the fit of the TT-fabricated frameworks. The framework fit can differ according to the span of the edentate ridge and the fabrication technique for the metal framework. Elsevier 2015-07 2015-04-24 /pmc/articles/PMC4501440/ /pubmed/26236129 http://dx.doi.org/10.1016/j.sdentj.2014.11.013 Text en © 2015 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Anan, Mohammad Tarek M.
Al-Saadi, Mohannad H.
Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study
title Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study
title_full Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study
title_fullStr Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study
title_full_unstemmed Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study
title_short Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study
title_sort fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4501440/
https://www.ncbi.nlm.nih.gov/pubmed/26236129
http://dx.doi.org/10.1016/j.sdentj.2014.11.013
work_keys_str_mv AT ananmohammadtarekm fitaccuracyofmetalpartialremovabledentalprosthesisframeworksfabricatedbytraditionalorlightcuringmodelingmaterialtechniqueaninvitrostudy
AT alsaadimohannadh fitaccuracyofmetalpartialremovabledentalprosthesisframeworksfabricatedbytraditionalorlightcuringmodelingmaterialtechniqueaninvitrostudy