Cargando…

The performance of the SD BIOLINE Dengue DUO® rapid immunochromatographic test kit for the detection of NS1 antigen, IgM and IgG antibodies during a dengue type 1 epidemic in Jamaica

BACKGROUND: Dengue is an important mosquito-borne viral infection that affects millions of persons worldwide. Early diagnosis is necessary to effect appropriate management and decrease mortality. Immunochromatographic tests are advantageous in producing dengue test results within 30 min but these re...

Descripción completa

Detalles Bibliográficos
Autores principales: Vickers, Ivan E., Harvey, Kevin M., Brown, Michelle G., Nelson, Kereann, DuCasse, Marion Bullock, Lindo, John F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4502463/
https://www.ncbi.nlm.nih.gov/pubmed/26173484
http://dx.doi.org/10.1186/s12929-015-0164-9
Descripción
Sumario:BACKGROUND: Dengue is an important mosquito-borne viral infection that affects millions of persons worldwide. Early diagnosis is necessary to effect appropriate management and decrease mortality. Immunochromatographic tests are advantageous in producing dengue test results within 30 min but these results should be sensitive and specific. In this study we evaluated the diagnostic performance of the SD BIOLINE Dengue DUO® rapid immunochromatographic test kit. A panel of 309 dengue and 30 non-dengue single serum samples characterized by using reference enzyme-linked immunosorbent assays (ELISAs) was used. These samples were received in the virology laboratory for routine testing during a dengue type 1 outbreak between October to December, 2012. RESULTS: The overall diagnostic sensitivities of the SD BIOLINE Dengue DUO® rapid testfor IgM, IgG and NSI were 49.3 % (95 % CI: 41.3-57.4), 39.1 % (95 % CI: 33.3-45.2) and 90 % (95 % CI: 82.1-94.7), respectively. The IgM and IgG detection rates were significantly lower than that of the NSI (p < 0.001). However the combination of the IgM detection with NS1 detection or both NS1 and IgG resulted in a significant (p < 0.001) increase in sensitivity to 97.5 % (95 % CI: 92.9-99.2) and 98.9 % (95 % CI: 96.0-99.7), respectively. These higher sensitivities were achieved without any decrease in specificities. CONCLUSIONS: This study revealed that combining two or more parameters of the SD BIOLINE Dengue DUO® rapid kit significantly improved the sensitivity of diagnosis of dengue virus infection and supports its usefulness in the Jamaican setting.