Cargando…
HiFocus Helix™ electrode insertion: surgical approach
BACKGROUND: Cochlear implants have been used for almost 30 years as a device for the rehabilitation of individuals with severe-to-profound hearing loss. One of the important aspects of cochlear implantation is the type of electrode selected and proper insertion of the electrode array in scala tympan...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4502906/ https://www.ncbi.nlm.nih.gov/pubmed/26174835 http://dx.doi.org/10.1186/s13104-015-1267-9 |
_version_ | 1782381270748102656 |
---|---|
author | Castilho, Arthur Menino Pauna, Henrique Furlan Fernandes, Fernando Laffitte Bonhin, Rodrigo Gonzales Guimarães, Alexandre Caixeta de Melo, Tatiana Mendes Cheng, Margareth Sartorato, Edi Lucia de Carvalho, Guilherme Machado Paschoal, Jorge Rizzato |
author_facet | Castilho, Arthur Menino Pauna, Henrique Furlan Fernandes, Fernando Laffitte Bonhin, Rodrigo Gonzales Guimarães, Alexandre Caixeta de Melo, Tatiana Mendes Cheng, Margareth Sartorato, Edi Lucia de Carvalho, Guilherme Machado Paschoal, Jorge Rizzato |
author_sort | Castilho, Arthur Menino |
collection | PubMed |
description | BACKGROUND: Cochlear implants have been used for almost 30 years as a device for the rehabilitation of individuals with severe-to-profound hearing loss. One of the important aspects of cochlear implantation is the type of electrode selected and proper insertion of the electrode array in scala tympani to minimize cochlear damage. The HiFocus Helix™ electrode is a precurved design aimed at placing the electrode contacts close to the spiral ganglion cells in the modiolus. The prescribed insertion techniques are intended to minimize the likelihood of damage to the basilar membrane or lateral wall of the cochlea. CASE PRESENTATION: To describe the first insertion of a HiFocus Helix™ electrode in Brazil exposing surgical particularities and device details in a patient with profound hearing loss, due to Mondini’s dysplasia. CONCLUSION: No problems were encountered during the surgical procedure. The patient experienced improvement in hearing thresholds and speech perception. The HiFocus Helix™ electrode proved easy to insert and provided expected hearing benefits for the patient. This manuscript indicates that the HiResolution™ Bionic Ear System with HiFocus Helix™ electrode comprise a cochlear implant system that is practical and beneficial for the treatment of severe-to-profound hearing loss. |
format | Online Article Text |
id | pubmed-4502906 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45029062015-07-16 HiFocus Helix™ electrode insertion: surgical approach Castilho, Arthur Menino Pauna, Henrique Furlan Fernandes, Fernando Laffitte Bonhin, Rodrigo Gonzales Guimarães, Alexandre Caixeta de Melo, Tatiana Mendes Cheng, Margareth Sartorato, Edi Lucia de Carvalho, Guilherme Machado Paschoal, Jorge Rizzato BMC Res Notes Case Report BACKGROUND: Cochlear implants have been used for almost 30 years as a device for the rehabilitation of individuals with severe-to-profound hearing loss. One of the important aspects of cochlear implantation is the type of electrode selected and proper insertion of the electrode array in scala tympani to minimize cochlear damage. The HiFocus Helix™ electrode is a precurved design aimed at placing the electrode contacts close to the spiral ganglion cells in the modiolus. The prescribed insertion techniques are intended to minimize the likelihood of damage to the basilar membrane or lateral wall of the cochlea. CASE PRESENTATION: To describe the first insertion of a HiFocus Helix™ electrode in Brazil exposing surgical particularities and device details in a patient with profound hearing loss, due to Mondini’s dysplasia. CONCLUSION: No problems were encountered during the surgical procedure. The patient experienced improvement in hearing thresholds and speech perception. The HiFocus Helix™ electrode proved easy to insert and provided expected hearing benefits for the patient. This manuscript indicates that the HiResolution™ Bionic Ear System with HiFocus Helix™ electrode comprise a cochlear implant system that is practical and beneficial for the treatment of severe-to-profound hearing loss. BioMed Central 2015-07-15 /pmc/articles/PMC4502906/ /pubmed/26174835 http://dx.doi.org/10.1186/s13104-015-1267-9 Text en © Castilho et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Castilho, Arthur Menino Pauna, Henrique Furlan Fernandes, Fernando Laffitte Bonhin, Rodrigo Gonzales Guimarães, Alexandre Caixeta de Melo, Tatiana Mendes Cheng, Margareth Sartorato, Edi Lucia de Carvalho, Guilherme Machado Paschoal, Jorge Rizzato HiFocus Helix™ electrode insertion: surgical approach |
title | HiFocus Helix™ electrode insertion: surgical approach |
title_full | HiFocus Helix™ electrode insertion: surgical approach |
title_fullStr | HiFocus Helix™ electrode insertion: surgical approach |
title_full_unstemmed | HiFocus Helix™ electrode insertion: surgical approach |
title_short | HiFocus Helix™ electrode insertion: surgical approach |
title_sort | hifocus helix™ electrode insertion: surgical approach |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4502906/ https://www.ncbi.nlm.nih.gov/pubmed/26174835 http://dx.doi.org/10.1186/s13104-015-1267-9 |
work_keys_str_mv | AT castilhoarthurmenino hifocushelixelectrodeinsertionsurgicalapproach AT paunahenriquefurlan hifocushelixelectrodeinsertionsurgicalapproach AT fernandesfernandolaffitte hifocushelixelectrodeinsertionsurgicalapproach AT bonhinrodrigogonzales hifocushelixelectrodeinsertionsurgicalapproach AT guimaraesalexandrecaixeta hifocushelixelectrodeinsertionsurgicalapproach AT demelotatianamendes hifocushelixelectrodeinsertionsurgicalapproach AT chengmargareth hifocushelixelectrodeinsertionsurgicalapproach AT sartoratoedilucia hifocushelixelectrodeinsertionsurgicalapproach AT decarvalhoguilhermemachado hifocushelixelectrodeinsertionsurgicalapproach AT paschoaljorgerizzato hifocushelixelectrodeinsertionsurgicalapproach |