Cargando…
No Added Value of Novel Biomarkers in the Diagnostic Assessment of Patients Suspected of Acute Coronary Syndrome
BACKGROUND: Despite the availability of high-sensitive troponin (hs-cTnT), there is still room for improvement in the diagnostic assessment of patients suspected of acute coronary syndrome (ACS). Apart from serial biomarker testing, which is time-consuming, novel biomarkers like copeptin have been p...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4503345/ https://www.ncbi.nlm.nih.gov/pubmed/26177390 http://dx.doi.org/10.1371/journal.pone.0132000 |
Sumario: | BACKGROUND: Despite the availability of high-sensitive troponin (hs-cTnT), there is still room for improvement in the diagnostic assessment of patients suspected of acute coronary syndrome (ACS). Apart from serial biomarker testing, which is time-consuming, novel biomarkers like copeptin have been proposed to expedite the early diagnosis of suspected ACS in addition to hs-cTnT. We determined whether placenta derived growth factor (PlGF), soluble Fms-like tyrosine kinase 1 (sFlt-1), myoglobin, N-terminal prohormone B-type Natriuretic Peptide (NT-proBNP), growth-differentiation factor 15 (GDF-15) and copeptin improved early assessment of chest pain patients. METHODS: This prospective, single centre diagnostic FAME-ER study included patients presenting to the ED with symptoms suggestive of ACS. Blood was collected to measure biomarkers, notably, hs-cTnT was retrospectively assessed. Added value of markers was judged by increase in AUC using multivariable logistic regression. RESULTS: Of 453 patients enrolled, 149 (33%) received a final diagnosis of ACS. Hs-cTnT had the highest diagnostic value in both univariable and multivariable analysis. PPVs of the biomarkers ranged from 23.5% (PlGF) to 77.9% (hs-cTnT), NPVs from 67.0% (PlGF) to 86.4% (hs-cTnT). Only myoglobin yielded diagnostic value in addition to clinical symptoms and electrocardiography (ECG) (AUC of clinical model 0.80) with AUC of 0.84 (p<0.001). However, addition of hs-cTnT was superior (AUC 0.89, p<0.001). Addition of the biomarkers to our clinical model and hs-cTnT did not or only marginally (GDF-15) improved diagnostic performance. CONCLUSION: When assessing patients suspected of ACS, only myoglobin had added diagnostic value beyond clinical symptoms and ECG. However, when combined with hs-cTnT, it yields no additional diagnostic value. PlGF, sFlt-1, NT-proBNP, GDF-15 and copeptin had no added value to the clinical model or hs-cTnT. |
---|