Cargando…

Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners

Humans show a remarkable ability to understand continuous speech even under adverse listening conditions. This ability critically relies on dynamically updated predictions of incoming sensory information, but exactly how top-down predictions improve speech processing is still unclear. Brain oscillat...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Hyojin, Ince, Robin A.A., Schyns, Philippe G., Thut, Gregor, Gross, Joachim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cell Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4503802/
https://www.ncbi.nlm.nih.gov/pubmed/26028433
http://dx.doi.org/10.1016/j.cub.2015.04.049
_version_ 1782381365823537152
author Park, Hyojin
Ince, Robin A.A.
Schyns, Philippe G.
Thut, Gregor
Gross, Joachim
author_facet Park, Hyojin
Ince, Robin A.A.
Schyns, Philippe G.
Thut, Gregor
Gross, Joachim
author_sort Park, Hyojin
collection PubMed
description Humans show a remarkable ability to understand continuous speech even under adverse listening conditions. This ability critically relies on dynamically updated predictions of incoming sensory information, but exactly how top-down predictions improve speech processing is still unclear. Brain oscillations are a likely mechanism for these top-down predictions [1, 2]. Quasi-rhythmic components in speech are known to entrain low-frequency oscillations in auditory areas [3, 4], and this entrainment increases with intelligibility [5]. We hypothesize that top-down signals from frontal brain areas causally modulate the phase of brain oscillations in auditory cortex. We use magnetoencephalography (MEG) to monitor brain oscillations in 22 participants during continuous speech perception. We characterize prominent spectral components of speech-brain coupling in auditory cortex and use causal connectivity analysis (transfer entropy) to identify the top-down signals driving this coupling more strongly during intelligible speech than during unintelligible speech. We report three main findings. First, frontal and motor cortices significantly modulate the phase of speech-coupled low-frequency oscillations in auditory cortex, and this effect depends on intelligibility of speech. Second, top-down signals are significantly stronger for left auditory cortex than for right auditory cortex. Third, speech-auditory cortex coupling is enhanced as a function of stronger top-down signals. Together, our results suggest that low-frequency brain oscillations play a role in implementing predictive top-down control during continuous speech perception and that top-down control is largely directed at left auditory cortex. This suggests a close relationship between (left-lateralized) speech production areas and the implementation of top-down control in continuous speech perception.
format Online
Article
Text
id pubmed-4503802
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Cell Press
record_format MEDLINE/PubMed
spelling pubmed-45038022015-07-21 Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners Park, Hyojin Ince, Robin A.A. Schyns, Philippe G. Thut, Gregor Gross, Joachim Curr Biol Report Humans show a remarkable ability to understand continuous speech even under adverse listening conditions. This ability critically relies on dynamically updated predictions of incoming sensory information, but exactly how top-down predictions improve speech processing is still unclear. Brain oscillations are a likely mechanism for these top-down predictions [1, 2]. Quasi-rhythmic components in speech are known to entrain low-frequency oscillations in auditory areas [3, 4], and this entrainment increases with intelligibility [5]. We hypothesize that top-down signals from frontal brain areas causally modulate the phase of brain oscillations in auditory cortex. We use magnetoencephalography (MEG) to monitor brain oscillations in 22 participants during continuous speech perception. We characterize prominent spectral components of speech-brain coupling in auditory cortex and use causal connectivity analysis (transfer entropy) to identify the top-down signals driving this coupling more strongly during intelligible speech than during unintelligible speech. We report three main findings. First, frontal and motor cortices significantly modulate the phase of speech-coupled low-frequency oscillations in auditory cortex, and this effect depends on intelligibility of speech. Second, top-down signals are significantly stronger for left auditory cortex than for right auditory cortex. Third, speech-auditory cortex coupling is enhanced as a function of stronger top-down signals. Together, our results suggest that low-frequency brain oscillations play a role in implementing predictive top-down control during continuous speech perception and that top-down control is largely directed at left auditory cortex. This suggests a close relationship between (left-lateralized) speech production areas and the implementation of top-down control in continuous speech perception. Cell Press 2015-06-15 /pmc/articles/PMC4503802/ /pubmed/26028433 http://dx.doi.org/10.1016/j.cub.2015.04.049 Text en © 2015 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Report
Park, Hyojin
Ince, Robin A.A.
Schyns, Philippe G.
Thut, Gregor
Gross, Joachim
Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners
title Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners
title_full Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners
title_fullStr Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners
title_full_unstemmed Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners
title_short Frontal Top-Down Signals Increase Coupling of Auditory Low-Frequency Oscillations to Continuous Speech in Human Listeners
title_sort frontal top-down signals increase coupling of auditory low-frequency oscillations to continuous speech in human listeners
topic Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4503802/
https://www.ncbi.nlm.nih.gov/pubmed/26028433
http://dx.doi.org/10.1016/j.cub.2015.04.049
work_keys_str_mv AT parkhyojin frontaltopdownsignalsincreasecouplingofauditorylowfrequencyoscillationstocontinuousspeechinhumanlisteners
AT incerobinaa frontaltopdownsignalsincreasecouplingofauditorylowfrequencyoscillationstocontinuousspeechinhumanlisteners
AT schynsphilippeg frontaltopdownsignalsincreasecouplingofauditorylowfrequencyoscillationstocontinuousspeechinhumanlisteners
AT thutgregor frontaltopdownsignalsincreasecouplingofauditorylowfrequencyoscillationstocontinuousspeechinhumanlisteners
AT grossjoachim frontaltopdownsignalsincreasecouplingofauditorylowfrequencyoscillationstocontinuousspeechinhumanlisteners