Cargando…

Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study

Background. Cryptococcus neoformans is the most common cause of adult meningitis in sub-Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified diagnosis as a point-of-care test approved for serum or cerebrospinal fluid (CSF). We evaluated the accuracy of the CRAG LFA...

Descripción completa

Detalles Bibliográficos
Autores principales: Williams, Darlisha A., Kiiza, Tadeo, Kwizera, Richard, Kiggundu, Reuben, Velamakanni, Sruti, Meya, David B., Rhein, Joshua, Boulware, David R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4503809/
https://www.ncbi.nlm.nih.gov/pubmed/25838287
http://dx.doi.org/10.1093/cid/civ263
_version_ 1782381367417372672
author Williams, Darlisha A.
Kiiza, Tadeo
Kwizera, Richard
Kiggundu, Reuben
Velamakanni, Sruti
Meya, David B.
Rhein, Joshua
Boulware, David R.
author_facet Williams, Darlisha A.
Kiiza, Tadeo
Kwizera, Richard
Kiggundu, Reuben
Velamakanni, Sruti
Meya, David B.
Rhein, Joshua
Boulware, David R.
author_sort Williams, Darlisha A.
collection PubMed
description Background. Cryptococcus neoformans is the most common cause of adult meningitis in sub-Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified diagnosis as a point-of-care test approved for serum or cerebrospinal fluid (CSF). We evaluated the accuracy of the CRAG LFA using fingerstick whole blood compared with serum/plasma and CSF for diagnosing meningitis. Methods. From August 2013 to August 2014, CRAG LFA (IMMY, Norman, Oklahoma) tests were performed on fingerstick whole blood, plasma/serum, and CSF in 207 HIV-infected adults with suspected meningitis in Kampala, Uganda. Venous blood was also collected and centrifuged to obtain serum and/or plasma. CSF was tested after lumbar puncture. Results. Of 207 participants, 149 (72%) had fingerstick CRAG-positive results. There was 100% agreement between fingerstick whole blood and serum/plasma. Of the 149 fingerstick CRAG-positive participants, 138 (93%) had evidence of cryptococcal meningitis with a positive CSF CRAG. Eleven participants (5%) had isolated cryptococcal antigenemia with a negative CSF CRAG and culture, of whom 8 had CSF abnormalities (n = 3 lymphocytic pleocytosis, n = 5 elevated protein, n = 4 increased opening pressure). No persons with cryptococcal meningitis had negative fingersticks. Conclusions. The 100% agreement between whole blood, serum, and plasma CRAG LFA results demonstrates that fingerstick CRAG is a reliable bedside diagnostic test. Using point-of-care CRAG testing simplifies screening large numbers of patients and enables physicians to prioritize on whom to measure CSF opening pressure using manometers.
format Online
Article
Text
id pubmed-4503809
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-45038092015-07-17 Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study Williams, Darlisha A. Kiiza, Tadeo Kwizera, Richard Kiggundu, Reuben Velamakanni, Sruti Meya, David B. Rhein, Joshua Boulware, David R. Clin Infect Dis HIV/AIDS Background. Cryptococcus neoformans is the most common cause of adult meningitis in sub-Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified diagnosis as a point-of-care test approved for serum or cerebrospinal fluid (CSF). We evaluated the accuracy of the CRAG LFA using fingerstick whole blood compared with serum/plasma and CSF for diagnosing meningitis. Methods. From August 2013 to August 2014, CRAG LFA (IMMY, Norman, Oklahoma) tests were performed on fingerstick whole blood, plasma/serum, and CSF in 207 HIV-infected adults with suspected meningitis in Kampala, Uganda. Venous blood was also collected and centrifuged to obtain serum and/or plasma. CSF was tested after lumbar puncture. Results. Of 207 participants, 149 (72%) had fingerstick CRAG-positive results. There was 100% agreement between fingerstick whole blood and serum/plasma. Of the 149 fingerstick CRAG-positive participants, 138 (93%) had evidence of cryptococcal meningitis with a positive CSF CRAG. Eleven participants (5%) had isolated cryptococcal antigenemia with a negative CSF CRAG and culture, of whom 8 had CSF abnormalities (n = 3 lymphocytic pleocytosis, n = 5 elevated protein, n = 4 increased opening pressure). No persons with cryptococcal meningitis had negative fingersticks. Conclusions. The 100% agreement between whole blood, serum, and plasma CRAG LFA results demonstrates that fingerstick CRAG is a reliable bedside diagnostic test. Using point-of-care CRAG testing simplifies screening large numbers of patients and enables physicians to prioritize on whom to measure CSF opening pressure using manometers. Oxford University Press 2015-08-01 2015-04-01 /pmc/articles/PMC4503809/ /pubmed/25838287 http://dx.doi.org/10.1093/cid/civ263 Text en © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com.
spellingShingle HIV/AIDS
Williams, Darlisha A.
Kiiza, Tadeo
Kwizera, Richard
Kiggundu, Reuben
Velamakanni, Sruti
Meya, David B.
Rhein, Joshua
Boulware, David R.
Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
title Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
title_full Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
title_fullStr Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
title_full_unstemmed Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
title_short Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
title_sort evaluation of fingerstick cryptococcal antigen lateral flow assay in hiv-infected persons: a diagnostic accuracy study
topic HIV/AIDS
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4503809/
https://www.ncbi.nlm.nih.gov/pubmed/25838287
http://dx.doi.org/10.1093/cid/civ263
work_keys_str_mv AT williamsdarlishaa evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy
AT kiizatadeo evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy
AT kwizerarichard evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy
AT kiggundureuben evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy
AT velamakannisruti evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy
AT meyadavidb evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy
AT rheinjoshua evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy
AT boulwaredavidr evaluationoffingerstickcryptococcalantigenlateralflowassayinhivinfectedpersonsadiagnosticaccuracystudy