Cargando…

Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics

BACKGROUND: Perimembranous Ventricular Septal Defect (PMVSD) is the most common subtype of ventricular septal defects. Transcatheter closure of PMVSD is a challenging procedure in management of moderate or large defects. OBJECTIVES: The purpose of this study was to show that transcatheter closure of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ghaderian, Mehdi, Merajie, Mahmood, Mortezaeian, Hodjjat, Aarabi, Moghadam, Mohammad, Yoosef, Shah Mohammadi, Akbar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4506009/
https://www.ncbi.nlm.nih.gov/pubmed/26196005
http://dx.doi.org/10.5812/ijp.386
_version_ 1782381624618385408
author Ghaderian, Mehdi
Merajie, Mahmood
Mortezaeian, Hodjjat
Aarabi, Moghadam
Mohammad, Yoosef
Shah Mohammadi, Akbar
author_facet Ghaderian, Mehdi
Merajie, Mahmood
Mortezaeian, Hodjjat
Aarabi, Moghadam
Mohammad, Yoosef
Shah Mohammadi, Akbar
author_sort Ghaderian, Mehdi
collection PubMed
description BACKGROUND: Perimembranous Ventricular Septal Defect (PMVSD) is the most common subtype of ventricular septal defects. Transcatheter closure of PMVSD is a challenging procedure in management of moderate or large defects. OBJECTIVES: The purpose of this study was to show that transcatheter closure of perimembranous ventricular septal defect with Amplatzer Ductal Occluder (ADO) is an effective and safe method. PATIENTS AND METHODS: Between April 2012 and April 2013, 28 patients underwent percutaneous closure of PMVSD using ADO. After obtaining the size of VSD from the ventriculogram a device at least 2 mm larger than the narrowest diameter of VSD at right ventricular side was chosen. The device deployed after confirmation of its good position by echocardiography and left ventriculography. Follow up evaluations were done 1 month, 6 months, 12 months and yearly after discharge with transthoracic echocardiography and 12 lead electrocardiography. RESULTS: The mean age of patients at procedure was 4.7 ± 6.3 (range 2 to 14) years, mean weight 14.7 ± 10.5 (range 10 to 40) kg. The mean defect size of the right ventricular side was 4.5 ± 1.6 mm. The average device size used was 7.3 ± 3.2mm (range 4 to 12 mm). The ADOs were successfully implanted in all patients. The VSD occlusion rate was 65.7% at completion of the procedure, rising up to 79.5% at discharge and 96.4% during follow-up. Small residual shunts were seen at completion of the procedure, but they disappeared during follow-up in all but one patient. The mean follow-up period was 8.3 ± 3.6 months (range 1 to 18 months). Complete atrioventricular block (CAVB), major complication or death was not observed in our study. CONCLUSIONS: Transcatheter closure of PMVSD with ADO in children is a safe and effective treatment associated with excellent success and closure rates, but long-term follow-up in a large number of patients would be warranted.
format Online
Article
Text
id pubmed-4506009
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-45060092015-07-20 Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics Ghaderian, Mehdi Merajie, Mahmood Mortezaeian, Hodjjat Aarabi, Moghadam Mohammad, Yoosef Shah Mohammadi, Akbar Iran J Pediatr Research Article BACKGROUND: Perimembranous Ventricular Septal Defect (PMVSD) is the most common subtype of ventricular septal defects. Transcatheter closure of PMVSD is a challenging procedure in management of moderate or large defects. OBJECTIVES: The purpose of this study was to show that transcatheter closure of perimembranous ventricular septal defect with Amplatzer Ductal Occluder (ADO) is an effective and safe method. PATIENTS AND METHODS: Between April 2012 and April 2013, 28 patients underwent percutaneous closure of PMVSD using ADO. After obtaining the size of VSD from the ventriculogram a device at least 2 mm larger than the narrowest diameter of VSD at right ventricular side was chosen. The device deployed after confirmation of its good position by echocardiography and left ventriculography. Follow up evaluations were done 1 month, 6 months, 12 months and yearly after discharge with transthoracic echocardiography and 12 lead electrocardiography. RESULTS: The mean age of patients at procedure was 4.7 ± 6.3 (range 2 to 14) years, mean weight 14.7 ± 10.5 (range 10 to 40) kg. The mean defect size of the right ventricular side was 4.5 ± 1.6 mm. The average device size used was 7.3 ± 3.2mm (range 4 to 12 mm). The ADOs were successfully implanted in all patients. The VSD occlusion rate was 65.7% at completion of the procedure, rising up to 79.5% at discharge and 96.4% during follow-up. Small residual shunts were seen at completion of the procedure, but they disappeared during follow-up in all but one patient. The mean follow-up period was 8.3 ± 3.6 months (range 1 to 18 months). Complete atrioventricular block (CAVB), major complication or death was not observed in our study. CONCLUSIONS: Transcatheter closure of PMVSD with ADO in children is a safe and effective treatment associated with excellent success and closure rates, but long-term follow-up in a large number of patients would be warranted. Kowsar 2015-04-18 2015-04 /pmc/articles/PMC4506009/ /pubmed/26196005 http://dx.doi.org/10.5812/ijp.386 Text en Copyright © 2015, Growth & Development Research Center. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
spellingShingle Research Article
Ghaderian, Mehdi
Merajie, Mahmood
Mortezaeian, Hodjjat
Aarabi, Moghadam
Mohammad, Yoosef
Shah Mohammadi, Akbar
Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics
title Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics
title_full Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics
title_fullStr Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics
title_full_unstemmed Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics
title_short Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics
title_sort efficacy and safety of using amplatzer ductal occluder for transcatheter closure of perimembranous ventricular septal defect in pediatrics
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4506009/
https://www.ncbi.nlm.nih.gov/pubmed/26196005
http://dx.doi.org/10.5812/ijp.386
work_keys_str_mv AT ghaderianmehdi efficacyandsafetyofusingamplatzerductaloccluderfortranscatheterclosureofperimembranousventricularseptaldefectinpediatrics
AT merajiemahmood efficacyandsafetyofusingamplatzerductaloccluderfortranscatheterclosureofperimembranousventricularseptaldefectinpediatrics
AT mortezaeianhodjjat efficacyandsafetyofusingamplatzerductaloccluderfortranscatheterclosureofperimembranousventricularseptaldefectinpediatrics
AT aarabimoghadam efficacyandsafetyofusingamplatzerductaloccluderfortranscatheterclosureofperimembranousventricularseptaldefectinpediatrics
AT mohammadyoosef efficacyandsafetyofusingamplatzerductaloccluderfortranscatheterclosureofperimembranousventricularseptaldefectinpediatrics
AT shahmohammadiakbar efficacyandsafetyofusingamplatzerductaloccluderfortranscatheterclosureofperimembranousventricularseptaldefectinpediatrics