Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model

PURPOSE: Since the treatment options for symptomatic total meniscectomy patients are still limited, an anatomically shaped, polycarbonate urethane (PCU), total meniscus replacement was developed. This study evaluates the in vivo performance of the implant in a goat model, with a specific focus on th...

Descripción completa

Detalles Bibliográficos
Autores principales: Vrancken, A. C. T., Madej, W., Hannink, G., Verdonschot, N., van Tienen, T. G., Buma, P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4507942/
https://www.ncbi.nlm.nih.gov/pubmed/26192414
http://dx.doi.org/10.1371/journal.pone.0133138
_version_ 1782381868543377408
author Vrancken, A. C. T.
Madej, W.
Hannink, G.
Verdonschot, N.
van Tienen, T. G.
Buma, P.
author_facet Vrancken, A. C. T.
Madej, W.
Hannink, G.
Verdonschot, N.
van Tienen, T. G.
Buma, P.
author_sort Vrancken, A. C. T.
collection PubMed
description PURPOSE: Since the treatment options for symptomatic total meniscectomy patients are still limited, an anatomically shaped, polycarbonate urethane (PCU), total meniscus replacement was developed. This study evaluates the in vivo performance of the implant in a goat model, with a specific focus on the implant location in the joint, geometrical integrity of the implant and the effect of the implant on synovial membrane and articular cartilage histopathological condition. METHODS: The right medial meniscus of seven Saanen goats was replaced by the implant. Sham surgery (transection of the MCL, arthrotomy and MCL suturing) was performed in six animals. The contralateral knee joints of both groups served as control groups. After three months follow-up the following aspects of implant performance were evaluated: implant position, implant deformation and the histopathological condition of the synovium and cartilage. RESULTS: Implant geometry was well maintained during the three month implantation period. No signs of PCU wear were found and the implant did not induce an inflammatory response in the knee joint. In all animals, implant fixation was compromised due to suture breakage, wear or elongation, likely causing the increase in extrusion observed in the implant group. Both the femoral cartilage and tibial cartilage in direct contact with the implant showed increased damage compared to the sham and sham-control groups. CONCLUSION: This study demonstrates that the novel, anatomically shaped PCU total meniscal replacement is biocompatible and resistant to three months of physiological loading. Failure of the fixation sutures may have increased implant mobility, which probably induced implant extrusion and potentially stimulated cartilage degeneration. Evidently, redesigning the fixation method is necessary. Future animal studies should evaluate the improved fixation method and compare implant performance to current treatment standards, such as allografts.
format Online
Article
Text
id pubmed-4507942
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45079422015-07-24 Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model Vrancken, A. C. T. Madej, W. Hannink, G. Verdonschot, N. van Tienen, T. G. Buma, P. PLoS One Research Article PURPOSE: Since the treatment options for symptomatic total meniscectomy patients are still limited, an anatomically shaped, polycarbonate urethane (PCU), total meniscus replacement was developed. This study evaluates the in vivo performance of the implant in a goat model, with a specific focus on the implant location in the joint, geometrical integrity of the implant and the effect of the implant on synovial membrane and articular cartilage histopathological condition. METHODS: The right medial meniscus of seven Saanen goats was replaced by the implant. Sham surgery (transection of the MCL, arthrotomy and MCL suturing) was performed in six animals. The contralateral knee joints of both groups served as control groups. After three months follow-up the following aspects of implant performance were evaluated: implant position, implant deformation and the histopathological condition of the synovium and cartilage. RESULTS: Implant geometry was well maintained during the three month implantation period. No signs of PCU wear were found and the implant did not induce an inflammatory response in the knee joint. In all animals, implant fixation was compromised due to suture breakage, wear or elongation, likely causing the increase in extrusion observed in the implant group. Both the femoral cartilage and tibial cartilage in direct contact with the implant showed increased damage compared to the sham and sham-control groups. CONCLUSION: This study demonstrates that the novel, anatomically shaped PCU total meniscal replacement is biocompatible and resistant to three months of physiological loading. Failure of the fixation sutures may have increased implant mobility, which probably induced implant extrusion and potentially stimulated cartilage degeneration. Evidently, redesigning the fixation method is necessary. Future animal studies should evaluate the improved fixation method and compare implant performance to current treatment standards, such as allografts. Public Library of Science 2015-07-20 /pmc/articles/PMC4507942/ /pubmed/26192414 http://dx.doi.org/10.1371/journal.pone.0133138 Text en © 2015 Vrancken et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Vrancken, A. C. T.
Madej, W.
Hannink, G.
Verdonschot, N.
van Tienen, T. G.
Buma, P.
Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model
title Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model
title_full Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model
title_fullStr Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model
title_full_unstemmed Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model
title_short Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model
title_sort short term evaluation of an anatomically shaped polycarbonate urethane total meniscus replacement in a goat model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4507942/
https://www.ncbi.nlm.nih.gov/pubmed/26192414
http://dx.doi.org/10.1371/journal.pone.0133138
work_keys_str_mv AT vranckenact shorttermevaluationofananatomicallyshapedpolycarbonateurethanetotalmeniscusreplacementinagoatmodel
AT madejw shorttermevaluationofananatomicallyshapedpolycarbonateurethanetotalmeniscusreplacementinagoatmodel
AT hanninkg shorttermevaluationofananatomicallyshapedpolycarbonateurethanetotalmeniscusreplacementinagoatmodel
AT verdonschotn shorttermevaluationofananatomicallyshapedpolycarbonateurethanetotalmeniscusreplacementinagoatmodel
AT vantienentg shorttermevaluationofananatomicallyshapedpolycarbonateurethanetotalmeniscusreplacementinagoatmodel
AT bumap shorttermevaluationofananatomicallyshapedpolycarbonateurethanetotalmeniscusreplacementinagoatmodel