Cargando…

The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation

Left ventricular end-diastolic pressure (LVEDP) is the foundation of cardiac function assessment. Because of difficulties and risks associated with its direct measurement, correlates of LVEDP derived by pulmonary artery (PA) catheterization or transesophageal echocardiography (TEE) are commonly adop...

Descripción completa

Detalles Bibliográficos
Autores principales: Santosa, Claudia M., Rose, David D., Fleming, Neal W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4508382/
https://www.ncbi.nlm.nih.gov/pubmed/26236733
http://dx.doi.org/10.1155/2015/697327
_version_ 1782381922465349632
author Santosa, Claudia M.
Rose, David D.
Fleming, Neal W.
author_facet Santosa, Claudia M.
Rose, David D.
Fleming, Neal W.
author_sort Santosa, Claudia M.
collection PubMed
description Left ventricular end-diastolic pressure (LVEDP) is the foundation of cardiac function assessment. Because of difficulties and risks associated with its direct measurement, correlates of LVEDP derived by pulmonary artery (PA) catheterization or transesophageal echocardiography (TEE) are commonly adopted. TEE has the advantage of being less invasive; however TEE-based estimation of LVEDP using correlates such as left ventricular end-diastolic volume (LVEDV) has technical difficulties that limit its clinical usefulness. Using intraoperative acute normovolemic hemodilution (ANH) as a controlled hemorrhagic model, we examined various mitral flow parameters and three-dimensional reconstructions of left atrial volume as surrogates of LVEDP. Our results demonstrate that peak E wave velocity and left atrial end-diastolic volume (LAEDV) correlated with known changes in intravascular volume associated with ANH. Although left atrial volumetric analysis was done offline in our study, recent advances in echocardiographic software may allow for continuous display and real-time calculation of LAEDV. Along with the ease and reproducibility of acquiring Doppler images of flow across the mitral valve, these two correlates of LVEDP may justify a more widespread use of TEE to optimize intraoperative fluid management. The clinical applicability of peak E wave velocity and LAEDV still needs to be validated during uncontrolled resuscitation.
format Online
Article
Text
id pubmed-4508382
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-45083822015-08-02 The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation Santosa, Claudia M. Rose, David D. Fleming, Neal W. Biomed Res Int Clinical Study Left ventricular end-diastolic pressure (LVEDP) is the foundation of cardiac function assessment. Because of difficulties and risks associated with its direct measurement, correlates of LVEDP derived by pulmonary artery (PA) catheterization or transesophageal echocardiography (TEE) are commonly adopted. TEE has the advantage of being less invasive; however TEE-based estimation of LVEDP using correlates such as left ventricular end-diastolic volume (LVEDV) has technical difficulties that limit its clinical usefulness. Using intraoperative acute normovolemic hemodilution (ANH) as a controlled hemorrhagic model, we examined various mitral flow parameters and three-dimensional reconstructions of left atrial volume as surrogates of LVEDP. Our results demonstrate that peak E wave velocity and left atrial end-diastolic volume (LAEDV) correlated with known changes in intravascular volume associated with ANH. Although left atrial volumetric analysis was done offline in our study, recent advances in echocardiographic software may allow for continuous display and real-time calculation of LAEDV. Along with the ease and reproducibility of acquiring Doppler images of flow across the mitral valve, these two correlates of LVEDP may justify a more widespread use of TEE to optimize intraoperative fluid management. The clinical applicability of peak E wave velocity and LAEDV still needs to be validated during uncontrolled resuscitation. Hindawi Publishing Corporation 2015 2015-07-07 /pmc/articles/PMC4508382/ /pubmed/26236733 http://dx.doi.org/10.1155/2015/697327 Text en Copyright © 2015 Claudia M. Santosa et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Santosa, Claudia M.
Rose, David D.
Fleming, Neal W.
The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation
title The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation
title_full The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation
title_fullStr The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation
title_full_unstemmed The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation
title_short The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation
title_sort utility of 3d left atrial volume and mitral flow velocities as guides for acute volume resuscitation
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4508382/
https://www.ncbi.nlm.nih.gov/pubmed/26236733
http://dx.doi.org/10.1155/2015/697327
work_keys_str_mv AT santosaclaudiam theutilityof3dleftatrialvolumeandmitralflowvelocitiesasguidesforacutevolumeresuscitation
AT rosedavidd theutilityof3dleftatrialvolumeandmitralflowvelocitiesasguidesforacutevolumeresuscitation
AT flemingnealw theutilityof3dleftatrialvolumeandmitralflowvelocitiesasguidesforacutevolumeresuscitation
AT santosaclaudiam utilityof3dleftatrialvolumeandmitralflowvelocitiesasguidesforacutevolumeresuscitation
AT rosedavidd utilityof3dleftatrialvolumeandmitralflowvelocitiesasguidesforacutevolumeresuscitation
AT flemingnealw utilityof3dleftatrialvolumeandmitralflowvelocitiesasguidesforacutevolumeresuscitation