Cargando…

Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm

BACKGROUND: A model for measuring temporal summation (TS) by tonic noxious stimulation was recently proposed. However, methodological variations between studies make it difficult to reach a consensus regarding the way TS should be applied and calculated. The present study aimed to present a calculat...

Descripción completa

Detalles Bibliográficos
Autores principales: Suzan, Erica, Aviram, Joshua, Treister, Roi, Eisenberg, Elon, Pud, Dorit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4509538/
https://www.ncbi.nlm.nih.gov/pubmed/26213476
http://dx.doi.org/10.2147/JPR.S83352
_version_ 1782382047668469760
author Suzan, Erica
Aviram, Joshua
Treister, Roi
Eisenberg, Elon
Pud, Dorit
author_facet Suzan, Erica
Aviram, Joshua
Treister, Roi
Eisenberg, Elon
Pud, Dorit
author_sort Suzan, Erica
collection PubMed
description BACKGROUND: A model for measuring temporal summation (TS) by tonic noxious stimulation was recently proposed. However, methodological variations between studies make it difficult to reach a consensus regarding the way TS should be applied and calculated. The present study aimed to present a calculation method of TS magnitude produced by a tonic heat model in a large cohort of healthy subjects. METHODS: Noxious heat stimulation (46.5°C/2 minutes) was applied to the forearm of 154 subjects who continuously rated pain intensity using a computerized visual analog scale. TS was calculated by “mean group” and “individual” approaches. RESULTS: A “typical” pattern of pain response, characterized by a peak pain followed by a decrease in intensity to a nadir and subsequently a progressive increase in pain scores, was exhibited by 86.4% of the subjects. Using the “mean group” and “individual” calculation approaches, the mean ± standard deviation magnitudes of TS were 31.4±27.5 and 41.0±26.0, respectively (P<0.001). Additionally, using the individualized approach, we identified a different (“atypical”) response pattern among the rest of the subjects (13.6%). CONCLUSION: The results support the tonic heat model of TS for future utilization. The individualized TS calculation method seems advantageous since it better reflects individual magnitudes of TS.
format Online
Article
Text
id pubmed-4509538
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-45095382015-07-24 Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm Suzan, Erica Aviram, Joshua Treister, Roi Eisenberg, Elon Pud, Dorit J Pain Res Original Research BACKGROUND: A model for measuring temporal summation (TS) by tonic noxious stimulation was recently proposed. However, methodological variations between studies make it difficult to reach a consensus regarding the way TS should be applied and calculated. The present study aimed to present a calculation method of TS magnitude produced by a tonic heat model in a large cohort of healthy subjects. METHODS: Noxious heat stimulation (46.5°C/2 minutes) was applied to the forearm of 154 subjects who continuously rated pain intensity using a computerized visual analog scale. TS was calculated by “mean group” and “individual” approaches. RESULTS: A “typical” pattern of pain response, characterized by a peak pain followed by a decrease in intensity to a nadir and subsequently a progressive increase in pain scores, was exhibited by 86.4% of the subjects. Using the “mean group” and “individual” calculation approaches, the mean ± standard deviation magnitudes of TS were 31.4±27.5 and 41.0±26.0, respectively (P<0.001). Additionally, using the individualized approach, we identified a different (“atypical”) response pattern among the rest of the subjects (13.6%). CONCLUSION: The results support the tonic heat model of TS for future utilization. The individualized TS calculation method seems advantageous since it better reflects individual magnitudes of TS. Dove Medical Press 2015-07-16 /pmc/articles/PMC4509538/ /pubmed/26213476 http://dx.doi.org/10.2147/JPR.S83352 Text en © 2015 Suzan et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Suzan, Erica
Aviram, Joshua
Treister, Roi
Eisenberg, Elon
Pud, Dorit
Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm
title Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm
title_full Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm
title_fullStr Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm
title_full_unstemmed Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm
title_short Individually based measurement of temporal summation evoked by a noxious tonic heat paradigm
title_sort individually based measurement of temporal summation evoked by a noxious tonic heat paradigm
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4509538/
https://www.ncbi.nlm.nih.gov/pubmed/26213476
http://dx.doi.org/10.2147/JPR.S83352
work_keys_str_mv AT suzanerica individuallybasedmeasurementoftemporalsummationevokedbyanoxioustonicheatparadigm
AT aviramjoshua individuallybasedmeasurementoftemporalsummationevokedbyanoxioustonicheatparadigm
AT treisterroi individuallybasedmeasurementoftemporalsummationevokedbyanoxioustonicheatparadigm
AT eisenbergelon individuallybasedmeasurementoftemporalsummationevokedbyanoxioustonicheatparadigm
AT puddorit individuallybasedmeasurementoftemporalsummationevokedbyanoxioustonicheatparadigm