Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra

BACKGROUND: The Spectra Optia (SPO) is a novel continuous-flow centrifugal apheresis system based on the COBE Spectra (CSP) platform. There have been few attempts to validate the advantages of the SPO. We performed a retrospective study comparing the two cell separators for therapeutic plasma exchan...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Do-kyun, Kim, Sinyoung, Jeong, Seok Hoon, Kim, Hyun Ok, Kim, Hyung Jik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4510503/
https://www.ncbi.nlm.nih.gov/pubmed/26206687
http://dx.doi.org/10.3343/alm.2015.35.5.506
_version_ 1782382179936894976
author Kim, Do-kyun
Kim, Sinyoung
Jeong, Seok Hoon
Kim, Hyun Ok
Kim, Hyung Jik
author_facet Kim, Do-kyun
Kim, Sinyoung
Jeong, Seok Hoon
Kim, Hyun Ok
Kim, Hyung Jik
author_sort Kim, Do-kyun
collection PubMed
description BACKGROUND: The Spectra Optia (SPO) is a novel continuous-flow centrifugal apheresis system based on the COBE Spectra (CSP) platform. There have been few attempts to validate the advantages of the SPO. We performed a retrospective study comparing the two cell separators for therapeutic plasma exchange (TPE) procedures in kidney transplant (KT) patients and seeing efficacy and safety. METHODS: We analyzed 720 TPE procedures performed between August 2012 and July 2014. Procedures included desensitization TPE before KT and TPE for the management of acute and chronic antibody-mediated graft rejection. Demographic characteristics, operational TPE variables, and laboratory data were analyzed. RESULTS: Demographic characteristics for the SPO (n=389) and CSP (n=331) groups did not differ significantly. The procedure time to exchange one plasma volume was 94.2±10.3 min in the SPO group and 100.4±11.2 min in the CSP group (P<0.001). The plasma removal efficiency (PRE) was 92.5±4.9% in the SPO group and 83.2±3.7% in the CSP group (P<0.001). There were no significant differences across the two apheresis systems for changes in hematologic parameters. CONCLUSIONS: Compared with the CSP, the SPO was associated with an improved PRE and a shorter procedure time to exchange one plasma volume. Our results in KT patients show that the SPO is superior to the CSP in TPE procedures.
format Online
Article
Text
id pubmed-4510503
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-45105032015-09-01 Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra Kim, Do-kyun Kim, Sinyoung Jeong, Seok Hoon Kim, Hyun Ok Kim, Hyung Jik Ann Lab Med Original Article BACKGROUND: The Spectra Optia (SPO) is a novel continuous-flow centrifugal apheresis system based on the COBE Spectra (CSP) platform. There have been few attempts to validate the advantages of the SPO. We performed a retrospective study comparing the two cell separators for therapeutic plasma exchange (TPE) procedures in kidney transplant (KT) patients and seeing efficacy and safety. METHODS: We analyzed 720 TPE procedures performed between August 2012 and July 2014. Procedures included desensitization TPE before KT and TPE for the management of acute and chronic antibody-mediated graft rejection. Demographic characteristics, operational TPE variables, and laboratory data were analyzed. RESULTS: Demographic characteristics for the SPO (n=389) and CSP (n=331) groups did not differ significantly. The procedure time to exchange one plasma volume was 94.2±10.3 min in the SPO group and 100.4±11.2 min in the CSP group (P<0.001). The plasma removal efficiency (PRE) was 92.5±4.9% in the SPO group and 83.2±3.7% in the CSP group (P<0.001). There were no significant differences across the two apheresis systems for changes in hematologic parameters. CONCLUSIONS: Compared with the CSP, the SPO was associated with an improved PRE and a shorter procedure time to exchange one plasma volume. Our results in KT patients show that the SPO is superior to the CSP in TPE procedures. The Korean Society for Laboratory Medicine 2015-09 2015-07-15 /pmc/articles/PMC4510503/ /pubmed/26206687 http://dx.doi.org/10.3343/alm.2015.35.5.506 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Do-kyun
Kim, Sinyoung
Jeong, Seok Hoon
Kim, Hyun Ok
Kim, Hyung Jik
Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
title Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
title_full Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
title_fullStr Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
title_full_unstemmed Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
title_short Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
title_sort therapeutic plasma exchange using the spectra optia cell separator compared with the cobe spectra
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4510503/
https://www.ncbi.nlm.nih.gov/pubmed/26206687
http://dx.doi.org/10.3343/alm.2015.35.5.506
work_keys_str_mv AT kimdokyun therapeuticplasmaexchangeusingthespectraoptiacellseparatorcomparedwiththecobespectra
AT kimsinyoung therapeuticplasmaexchangeusingthespectraoptiacellseparatorcomparedwiththecobespectra
AT jeongseokhoon therapeuticplasmaexchangeusingthespectraoptiacellseparatorcomparedwiththecobespectra
AT kimhyunok therapeuticplasmaexchangeusingthespectraoptiacellseparatorcomparedwiththecobespectra
AT kimhyungjik therapeuticplasmaexchangeusingthespectraoptiacellseparatorcomparedwiththecobespectra