Therapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
BACKGROUND: The Spectra Optia (SPO) is a novel continuous-flow centrifugal apheresis system based on the COBE Spectra (CSP) platform. There have been few attempts to validate the advantages of the SPO. We performed a retrospective study comparing the two cell separators for therapeutic plasma exchan...
Autores principales: | Kim, Do-kyun, Kim, Sinyoung, Jeong, Seok Hoon, Kim, Hyun Ok, Kim, Hyung Jik |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4510503/ https://www.ncbi.nlm.nih.gov/pubmed/26206687 http://dx.doi.org/10.3343/alm.2015.35.5.506 |
Ejemplares similares
-
Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
por: Lee, Se-Na, et al.
Publicado: (2017) -
Spectra Optia(®) for Automated Red Blood Cell Exchange in Patients with Sickle Cell Disease: A NICE Medical Technology Guidance
por: Willits, Iain, et al.
Publicado: (2017) -
Erythrocyte depletion from bone marrow: performance evaluation after 50 clinical-scale depletions with Spectra Optia BMC
por: Kim-Wanner, Soo-Zin, et al.
Publicado: (2017) -
The safety and performance of the Spectra Optia apheresis system platelet depletion protocol in patients with elevated platelet counts
por: Lopert, Pamela, et al.
Publicado: (2022) -
PB2527: COMPARING REAL-LIFE VERSUS PREDICTED PARAMETERS WITH OPTIA SPECTRA IN RED BLOOD CELL EXCHANGE IN SICKLE-CELL DISEASE PATIENTS
por: Rumschisky, Pablo Palomo, et al.
Publicado: (2023)