Cargando…
Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma
High-resolution imaging techniques have increased the detection rate of adrenal incidentaloma. We developed a method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for detection of plasma free metanephrine (MN) and normetanephrine (NMN) and evaluated its analytical performance and clin...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4510505/ https://www.ncbi.nlm.nih.gov/pubmed/26206689 http://dx.doi.org/10.3343/alm.2015.35.5.519 |
_version_ | 1782382180377296896 |
---|---|
author | Lee, Sae-Mi Lee, Mi-Na Oh, Hyeon Ju Cho, Yoon Young Kim, Jae Hyeon Woo, Hye In Park, Hyung-Doo Lee, Soo-Youn |
author_facet | Lee, Sae-Mi Lee, Mi-Na Oh, Hyeon Ju Cho, Yoon Young Kim, Jae Hyeon Woo, Hye In Park, Hyung-Doo Lee, Soo-Youn |
author_sort | Lee, Sae-Mi |
collection | PubMed |
description | High-resolution imaging techniques have increased the detection rate of adrenal incidentaloma. We developed a method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for detection of plasma free metanephrine (MN) and normetanephrine (NMN) and evaluated its analytical performance and clinical efficacy in differential diagnosis of adrenal incidentaloma. After solid-phase extraction, chromatographic isolation of the analytes and internal standard was achieved by column elution in the LC-MS/MS system. The analytes were detected in multiple-reaction monitoring mode by using positive electrospray ionization: MN, transition m/z 180.1→165.1; NMN, m/z 166.1→134.1. This method was validated for linearity, precision, accuracy, lower limits of quantification and detection, extraction recovery, and the matrix effect. Plasma concentrations of MN and NMN of 14 patients with pheochromocytoma were compared with those of 17 healthy volunteers, 10 patients with essential hypertension, and 60 patients with adrenal adenoma. The assay's linear range was 0.04-50.0 and 0.08-100.0 nmol/L for MN and NMN, respectively. Assay imprecision was 1.86-7.50%. The accuracy ranged from -7.50% to 2.00%, and the mean recovery of MN and NMN was within the range 71.5-95.2%. Our LC-MS/MS method is rapid, accurate, and reliable and useful for differential diagnosis of adrenal incidentaloma. |
format | Online Article Text |
id | pubmed-4510505 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-45105052015-09-01 Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma Lee, Sae-Mi Lee, Mi-Na Oh, Hyeon Ju Cho, Yoon Young Kim, Jae Hyeon Woo, Hye In Park, Hyung-Doo Lee, Soo-Youn Ann Lab Med Brief Communication High-resolution imaging techniques have increased the detection rate of adrenal incidentaloma. We developed a method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for detection of plasma free metanephrine (MN) and normetanephrine (NMN) and evaluated its analytical performance and clinical efficacy in differential diagnosis of adrenal incidentaloma. After solid-phase extraction, chromatographic isolation of the analytes and internal standard was achieved by column elution in the LC-MS/MS system. The analytes were detected in multiple-reaction monitoring mode by using positive electrospray ionization: MN, transition m/z 180.1→165.1; NMN, m/z 166.1→134.1. This method was validated for linearity, precision, accuracy, lower limits of quantification and detection, extraction recovery, and the matrix effect. Plasma concentrations of MN and NMN of 14 patients with pheochromocytoma were compared with those of 17 healthy volunteers, 10 patients with essential hypertension, and 60 patients with adrenal adenoma. The assay's linear range was 0.04-50.0 and 0.08-100.0 nmol/L for MN and NMN, respectively. Assay imprecision was 1.86-7.50%. The accuracy ranged from -7.50% to 2.00%, and the mean recovery of MN and NMN was within the range 71.5-95.2%. Our LC-MS/MS method is rapid, accurate, and reliable and useful for differential diagnosis of adrenal incidentaloma. The Korean Society for Laboratory Medicine 2015-09 2015-07-15 /pmc/articles/PMC4510505/ /pubmed/26206689 http://dx.doi.org/10.3343/alm.2015.35.5.519 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Brief Communication Lee, Sae-Mi Lee, Mi-Na Oh, Hyeon Ju Cho, Yoon Young Kim, Jae Hyeon Woo, Hye In Park, Hyung-Doo Lee, Soo-Youn Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma |
title | Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma |
title_full | Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma |
title_fullStr | Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma |
title_full_unstemmed | Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma |
title_short | Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma |
title_sort | development and validation of liquid chromatography-tandem mass spectrometry method for quantification of plasma metanephrines for differential diagnosis of adrenal incidentaloma |
topic | Brief Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4510505/ https://www.ncbi.nlm.nih.gov/pubmed/26206689 http://dx.doi.org/10.3343/alm.2015.35.5.519 |
work_keys_str_mv | AT leesaemi developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma AT leemina developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma AT ohhyeonju developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma AT choyoonyoung developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma AT kimjaehyeon developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma AT woohyein developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma AT parkhyungdoo developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma AT leesooyoun developmentandvalidationofliquidchromatographytandemmassspectrometrymethodforquantificationofplasmametanephrinesfordifferentialdiagnosisofadrenalincidentaloma |