Cargando…
Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures
BACKGROUND: Incidence of vertebral compression fractures (VCFs) is increasing due to increase in human life expectancy and prevalence of osteoporosis. Vertebroplasty had been traditional treatment for pain, but it neither attempts to restore vertebral body height nor eliminates spinal deformity and...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4510802/ https://www.ncbi.nlm.nih.gov/pubmed/26229169 http://dx.doi.org/10.4103/0019-5413.159673 |
_version_ | 1782382244194680832 |
---|---|
author | Saxena, B Praveen Shah, B Viral Joshi, S Prateek |
author_facet | Saxena, B Praveen Shah, B Viral Joshi, S Prateek |
author_sort | Saxena, B Praveen |
collection | PubMed |
description | BACKGROUND: Incidence of vertebral compression fractures (VCFs) is increasing due to increase in human life expectancy and prevalence of osteoporosis. Vertebroplasty had been traditional treatment for pain, but it neither attempts to restore vertebral body height nor eliminates spinal deformity and is associated with a high rate of cement leakage. Balloon kyphoplasty involves introduction of inflatable balloon into the fractured body of vertebra for elevation of the end-plates prior to fixation of the fracture with bone cement. This study evaluates short term functional and radiological outcomes of balloon kyphoplasty. The secondary aim is to explore short-term complications of the procedure. MATERIALS AND METHODS: A retrospective study of 199 kyphoplasty procedures in 135 patients from March 2009 to March 2012 were evaluated with short form-36 (SF-36) score, visual analogue scale (VAS), detailed neurological and radiological evaluations. The mean followup was 18 months (range 12–20 months). Statistical analysis including paired sample t-test was done with statistical package for social sciences. RESULTS: Statistically significant improvements in SF-36 (from 34.29 to 48.53, an improvement of 14.24, standard deviation (SD) - 20.08 P < 0.0001), VAS (drop of 4.49, from 6.74 to 2.24, SD - 1.44, P < 0.0001), percentage restoration of lost vertebral height (from 30.62% to 16.19%, improvement of 14.43%, SD - 15.37, P < 0.0001) and kyphotic angle correction (from 17.41° to 10.59°, improvement of 6.82, SD - 7.26°, P < 0.0001) were noted postoperatively. Six patients had cement embolism, 65 had cement leak and three had adjacent level fracture which required repeat kyphoplasty later. One patient with history of ischemic heart disease had cardiac arrest during the procedure. No patients had neurological deterioration in the followup period. CONCLUSIONS: Kyphoplasty is a safe and effective treatment for VCFs. It improves physical function, reduces pain and corrects kyphotic deformity. |
format | Online Article Text |
id | pubmed-4510802 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-45108022015-07-30 Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures Saxena, B Praveen Shah, B Viral Joshi, S Prateek Indian J Orthop Original Article BACKGROUND: Incidence of vertebral compression fractures (VCFs) is increasing due to increase in human life expectancy and prevalence of osteoporosis. Vertebroplasty had been traditional treatment for pain, but it neither attempts to restore vertebral body height nor eliminates spinal deformity and is associated with a high rate of cement leakage. Balloon kyphoplasty involves introduction of inflatable balloon into the fractured body of vertebra for elevation of the end-plates prior to fixation of the fracture with bone cement. This study evaluates short term functional and radiological outcomes of balloon kyphoplasty. The secondary aim is to explore short-term complications of the procedure. MATERIALS AND METHODS: A retrospective study of 199 kyphoplasty procedures in 135 patients from March 2009 to March 2012 were evaluated with short form-36 (SF-36) score, visual analogue scale (VAS), detailed neurological and radiological evaluations. The mean followup was 18 months (range 12–20 months). Statistical analysis including paired sample t-test was done with statistical package for social sciences. RESULTS: Statistically significant improvements in SF-36 (from 34.29 to 48.53, an improvement of 14.24, standard deviation (SD) - 20.08 P < 0.0001), VAS (drop of 4.49, from 6.74 to 2.24, SD - 1.44, P < 0.0001), percentage restoration of lost vertebral height (from 30.62% to 16.19%, improvement of 14.43%, SD - 15.37, P < 0.0001) and kyphotic angle correction (from 17.41° to 10.59°, improvement of 6.82, SD - 7.26°, P < 0.0001) were noted postoperatively. Six patients had cement embolism, 65 had cement leak and three had adjacent level fracture which required repeat kyphoplasty later. One patient with history of ischemic heart disease had cardiac arrest during the procedure. No patients had neurological deterioration in the followup period. CONCLUSIONS: Kyphoplasty is a safe and effective treatment for VCFs. It improves physical function, reduces pain and corrects kyphotic deformity. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4510802/ /pubmed/26229169 http://dx.doi.org/10.4103/0019-5413.159673 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Saxena, B Praveen Shah, B Viral Joshi, S Prateek Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures |
title | Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures |
title_full | Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures |
title_fullStr | Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures |
title_full_unstemmed | Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures |
title_short | Outcome of percutaneous balloon kyphoplasty in vertebral compression fractures |
title_sort | outcome of percutaneous balloon kyphoplasty in vertebral compression fractures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4510802/ https://www.ncbi.nlm.nih.gov/pubmed/26229169 http://dx.doi.org/10.4103/0019-5413.159673 |
work_keys_str_mv | AT saxenabpraveen outcomeofpercutaneousballoonkyphoplastyinvertebralcompressionfractures AT shahbviral outcomeofpercutaneousballoonkyphoplastyinvertebralcompressionfractures AT joshisprateek outcomeofpercutaneousballoonkyphoplastyinvertebralcompressionfractures |