Cargando…

Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure

Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPO...

Descripción completa

Detalles Bibliográficos
Autores principales: Roy, Sanjoy, Hammond, Jeffrey, Panish, Jessica, Shnoda, Pullen, Savidge, Sandy, Wilson, Mark
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4512636/
https://www.ncbi.nlm.nih.gov/pubmed/26240834
http://dx.doi.org/10.1155/2015/340246
_version_ 1782382540503384064
author Roy, Sanjoy
Hammond, Jeffrey
Panish, Jessica
Shnoda, Pullen
Savidge, Sandy
Wilson, Mark
author_facet Roy, Sanjoy
Hammond, Jeffrey
Panish, Jessica
Shnoda, Pullen
Savidge, Sandy
Wilson, Mark
author_sort Roy, Sanjoy
collection PubMed
description Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAP(TM) Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Conclusions. Mechanical fixation with ETHICON SECURESTRAP(TM) Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure.
format Online
Article
Text
id pubmed-4512636
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-45126362015-08-03 Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure Roy, Sanjoy Hammond, Jeffrey Panish, Jessica Shnoda, Pullen Savidge, Sandy Wilson, Mark ScientificWorldJournal Research Article Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAP(TM) Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Conclusions. Mechanical fixation with ETHICON SECURESTRAP(TM) Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure. Hindawi Publishing Corporation 2015 2015-07-09 /pmc/articles/PMC4512636/ /pubmed/26240834 http://dx.doi.org/10.1155/2015/340246 Text en Copyright © 2015 Sanjoy Roy et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Roy, Sanjoy
Hammond, Jeffrey
Panish, Jessica
Shnoda, Pullen
Savidge, Sandy
Wilson, Mark
Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
title Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
title_full Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
title_fullStr Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
title_full_unstemmed Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
title_short Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
title_sort time savings and surgery task load reduction in open intraperitoneal onlay mesh fixation procedure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4512636/
https://www.ncbi.nlm.nih.gov/pubmed/26240834
http://dx.doi.org/10.1155/2015/340246
work_keys_str_mv AT roysanjoy timesavingsandsurgerytaskloadreductioninopenintraperitonealonlaymeshfixationprocedure
AT hammondjeffrey timesavingsandsurgerytaskloadreductioninopenintraperitonealonlaymeshfixationprocedure
AT panishjessica timesavingsandsurgerytaskloadreductioninopenintraperitonealonlaymeshfixationprocedure
AT shnodapullen timesavingsandsurgerytaskloadreductioninopenintraperitonealonlaymeshfixationprocedure
AT savidgesandy timesavingsandsurgerytaskloadreductioninopenintraperitonealonlaymeshfixationprocedure
AT wilsonmark timesavingsandsurgerytaskloadreductioninopenintraperitonealonlaymeshfixationprocedure