Cargando…

Fluoride adsorption on γ − Fe(2)O(3) nanoparticles

BACKGROUND: Fluoride contamination of groundwater, both anthropogenic and natural, is a major problem worldwide and hence its removal attracted much attention to have clean aquatic systems. In the present work, removal of fluoride ions from drinking water tested using synthesized γ-Fe(2)O(3) nanopar...

Descripción completa

Detalles Bibliográficos
Autores principales: Jayarathna, Lakmal, Bandara, Athula, Ng, W.J., Weerasooriya, Rohan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4513747/
https://www.ncbi.nlm.nih.gov/pubmed/26213628
http://dx.doi.org/10.1186/s40201-015-0210-2
Descripción
Sumario:BACKGROUND: Fluoride contamination of groundwater, both anthropogenic and natural, is a major problem worldwide and hence its removal attracted much attention to have clean aquatic systems. In the present work, removal of fluoride ions from drinking water tested using synthesized γ-Fe(2)O(3) nanoparticles. METHODS: Nanoparticles were synthesized in co-precipitation method. The prepared particles were first characterized by X-ray diffraction (XRD) and Transmission Electron Microscope (TEM). Density functional theory (DFT) calculations on molecular cluster were used to model infrared (IR) vibrational frequencies and inter atomic distances. RESULTS: The average size of the particles was around 5 nm initially and showed a aggregation upon exposure to the atmosphere for several hours giving average particle size of around 5–20 nm. Batch adsorption studies were performed for the adsorption of fluoride and the results revealed that γ-Fe(2)O(3) nanoparticles posses high efficiency towards adsorption. A rapid adsorption occurred during the initial 15 min by removing about 95 ± 3 % and reached equilibrium thereafter. Fluoride adsorption was found to be dependent on the aqueous phase pH and the uptake was observed to be greater at lower pH. Fourier transform infrared spectroscopy (FT-IR) was used for the identification of functional groups responsible for the adsorption and revealed that the direct interaction between fluoride and the γ-Fe(2)O(3) particles. CONCLUSIONS: The mechanism for fluoride removal was explained using the dehydoxylation pathway of the hydroxyl groups by the incoming fluoride ion. FT-IR data and other results from the ionic strength dependence strongly indicated that formation of inner-spherically bonded complexes. Molecular clusters were found to be good agreement with experimental observations. These results show direct chemical interaction with fluoride ions.