The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron

A Prompt Gamma Ray Neutron Activation Analysis (PGNAA) system, incorporating an isotopic neutron source has been simulated using the MCNPX Monte Carlo code. In order to improve the signal to noise ratio different collimators and a filter were placed between the neutron source and the object. The eff...

Descripción completa

Detalles Bibliográficos
Autores principales: Fantidis, J. G., Nicolaou, G. E., Potolias, C., Vordos, N., Bandekas, D. V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4514448/
https://www.ncbi.nlm.nih.gov/pubmed/26224910
http://dx.doi.org/10.1007/s10967-011-1315-4
_version_ 1782382766558543872
author Fantidis, J. G.
Nicolaou, G. E.
Potolias, C.
Vordos, N.
Bandekas, D. V.
author_facet Fantidis, J. G.
Nicolaou, G. E.
Potolias, C.
Vordos, N.
Bandekas, D. V.
author_sort Fantidis, J. G.
collection PubMed
description A Prompt Gamma Ray Neutron Activation Analysis (PGNAA) system, incorporating an isotopic neutron source has been simulated using the MCNPX Monte Carlo code. In order to improve the signal to noise ratio different collimators and a filter were placed between the neutron source and the object. The effect of the positioning of the neutron beam and the detector relative to the object has been studied. In this work the optimisation procedure is demonstrated for boron. Monte Carlo calculations were carried out to compare the performance of the proposed PGNAA system using four different neutron sources ((241)Am/Be, (252)Cf, (241)Am/B, and DT neutron generator). Among the different systems the (252)Cf neutron based PGNAA system has the best performance.
format Online
Article
Text
id pubmed-4514448
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-45144482015-07-27 The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron Fantidis, J. G. Nicolaou, G. E. Potolias, C. Vordos, N. Bandekas, D. V. J Radioanal Nucl Chem Article A Prompt Gamma Ray Neutron Activation Analysis (PGNAA) system, incorporating an isotopic neutron source has been simulated using the MCNPX Monte Carlo code. In order to improve the signal to noise ratio different collimators and a filter were placed between the neutron source and the object. The effect of the positioning of the neutron beam and the detector relative to the object has been studied. In this work the optimisation procedure is demonstrated for boron. Monte Carlo calculations were carried out to compare the performance of the proposed PGNAA system using four different neutron sources ((241)Am/Be, (252)Cf, (241)Am/B, and DT neutron generator). Among the different systems the (252)Cf neutron based PGNAA system has the best performance. Springer Netherlands 2011-07-17 2011 /pmc/articles/PMC4514448/ /pubmed/26224910 http://dx.doi.org/10.1007/s10967-011-1315-4 Text en © The Author(s) 2011 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Article
Fantidis, J. G.
Nicolaou, G. E.
Potolias, C.
Vordos, N.
Bandekas, D. V.
The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
title The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
title_full The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
title_fullStr The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
title_full_unstemmed The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
title_short The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
title_sort comparison of four neutron sources for prompt gamma neutron activation analysis (pgnaa) in vivo detections of boron
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4514448/
https://www.ncbi.nlm.nih.gov/pubmed/26224910
http://dx.doi.org/10.1007/s10967-011-1315-4
work_keys_str_mv AT fantidisjg thecomparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT nicolaouge thecomparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT potoliasc thecomparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT vordosn thecomparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT bandekasdv thecomparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT fantidisjg comparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT nicolaouge comparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT potoliasc comparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT vordosn comparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron
AT bandekasdv comparisonoffourneutronsourcesforpromptgammaneutronactivationanalysispgnaainvivodetectionsofboron