Cargando…

Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results

Infectious murine models greatly benefit from optical imaging using bioluminescent bacteria to non-invasively and repeatedly follow in vivo bacterial infection. In this context, one of the most critical parameters is the bioluminescence sensitivity to reliably detect the smallest number of bacteria....

Descripción completa

Detalles Bibliográficos
Autores principales: Chuzel, Thomas, Sanchez, Violette, Vandamme, Marc, Martin, Stéphane, Flety, Odile, Pager, Aurélie, Chabanel, Christophe, Magnier, Luc, Foskolos, Marie, Petit, Océane, Rokbi, Bachra, Chereul, Emmanuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4514857/
https://www.ncbi.nlm.nih.gov/pubmed/26208168
http://dx.doi.org/10.1371/journal.pone.0134048
_version_ 1782382827660115968
author Chuzel, Thomas
Sanchez, Violette
Vandamme, Marc
Martin, Stéphane
Flety, Odile
Pager, Aurélie
Chabanel, Christophe
Magnier, Luc
Foskolos, Marie
Petit, Océane
Rokbi, Bachra
Chereul, Emmanuel
author_facet Chuzel, Thomas
Sanchez, Violette
Vandamme, Marc
Martin, Stéphane
Flety, Odile
Pager, Aurélie
Chabanel, Christophe
Magnier, Luc
Foskolos, Marie
Petit, Océane
Rokbi, Bachra
Chereul, Emmanuel
author_sort Chuzel, Thomas
collection PubMed
description Infectious murine models greatly benefit from optical imaging using bioluminescent bacteria to non-invasively and repeatedly follow in vivo bacterial infection. In this context, one of the most critical parameters is the bioluminescence sensitivity to reliably detect the smallest number of bacteria. Another critical point is the anesthetic approaches that have been demonstrated to impact the bioluminescence flux emission in studies with luciferase-transfected tumor cells. However, this impact has never been assessed on bacteria bioluminescent models. To this end, we investigated the effects of four anesthesia protocols on the bioluminescence flux in a central venous catheter murine model (SKH1-hr(hr) mice) infected by a bioluminescent S. aureus Xen36 strain. Bioluminescence imaging was performed on mice anesthetized by either ketamine/xylazine (with or without oxygen supplementation), or isoflurane carried with air or oxygen. Total flux emission was determined in vivo daily for 3 days and ex vivo at the end of the study together with a CFU counting of the biofilm in the catheter. Bioluminescence flux differences appear between the different anesthetic protocols. Using a ketamine/xylazine anesthesia (with air), bacteria detection was impossible since the bioluminescence signal remains in the background signal. Mice anesthetized with isoflurane and oxygen led to a signal significantly higher to the background all along the kinetics. The use of isoflurane in air presents a bioluminescence signal similar to the use of ketamine/xylazine with oxygen. These data highlight the importance of oxygen to improve bioluminescence flux by bacteria with isoflurane as well as with ketamine/xylazine anesthetics. As a conclusion, we recommend the use of isoflurane anesthetic with oxygen to increase the bioluminescence sensitivity in this kind of study.
format Online
Article
Text
id pubmed-4514857
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45148572015-07-29 Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results Chuzel, Thomas Sanchez, Violette Vandamme, Marc Martin, Stéphane Flety, Odile Pager, Aurélie Chabanel, Christophe Magnier, Luc Foskolos, Marie Petit, Océane Rokbi, Bachra Chereul, Emmanuel PLoS One Research Article Infectious murine models greatly benefit from optical imaging using bioluminescent bacteria to non-invasively and repeatedly follow in vivo bacterial infection. In this context, one of the most critical parameters is the bioluminescence sensitivity to reliably detect the smallest number of bacteria. Another critical point is the anesthetic approaches that have been demonstrated to impact the bioluminescence flux emission in studies with luciferase-transfected tumor cells. However, this impact has never been assessed on bacteria bioluminescent models. To this end, we investigated the effects of four anesthesia protocols on the bioluminescence flux in a central venous catheter murine model (SKH1-hr(hr) mice) infected by a bioluminescent S. aureus Xen36 strain. Bioluminescence imaging was performed on mice anesthetized by either ketamine/xylazine (with or without oxygen supplementation), or isoflurane carried with air or oxygen. Total flux emission was determined in vivo daily for 3 days and ex vivo at the end of the study together with a CFU counting of the biofilm in the catheter. Bioluminescence flux differences appear between the different anesthetic protocols. Using a ketamine/xylazine anesthesia (with air), bacteria detection was impossible since the bioluminescence signal remains in the background signal. Mice anesthetized with isoflurane and oxygen led to a signal significantly higher to the background all along the kinetics. The use of isoflurane in air presents a bioluminescence signal similar to the use of ketamine/xylazine with oxygen. These data highlight the importance of oxygen to improve bioluminescence flux by bacteria with isoflurane as well as with ketamine/xylazine anesthetics. As a conclusion, we recommend the use of isoflurane anesthetic with oxygen to increase the bioluminescence sensitivity in this kind of study. Public Library of Science 2015-07-24 /pmc/articles/PMC4514857/ /pubmed/26208168 http://dx.doi.org/10.1371/journal.pone.0134048 Text en © 2015 Chuzel et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Chuzel, Thomas
Sanchez, Violette
Vandamme, Marc
Martin, Stéphane
Flety, Odile
Pager, Aurélie
Chabanel, Christophe
Magnier, Luc
Foskolos, Marie
Petit, Océane
Rokbi, Bachra
Chereul, Emmanuel
Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results
title Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results
title_full Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results
title_fullStr Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results
title_full_unstemmed Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results
title_short Impact of Anesthesia Protocols on In Vivo Bioluminescent Bacteria Imaging Results
title_sort impact of anesthesia protocols on in vivo bioluminescent bacteria imaging results
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4514857/
https://www.ncbi.nlm.nih.gov/pubmed/26208168
http://dx.doi.org/10.1371/journal.pone.0134048
work_keys_str_mv AT chuzelthomas impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT sanchezviolette impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT vandammemarc impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT martinstephane impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT fletyodile impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT pageraurelie impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT chabanelchristophe impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT magnierluc impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT foskolosmarie impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT petitoceane impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT rokbibachra impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults
AT chereulemmanuel impactofanesthesiaprotocolsoninvivobioluminescentbacteriaimagingresults