Cargando…
A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers
Serum and plasma calprotectin concentration is shown to be elevated when neutrophils are activated, and may therefore be used as a marker for inflammatory diseases. A serum calprotectin immunoassay was developed based on calprotectin values observed in samples from the intensive care unit. The polyc...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4514941/ https://www.ncbi.nlm.nih.gov/pubmed/26213499 http://dx.doi.org/10.1186/s12950-015-0090-3 |
_version_ | 1782382842111590400 |
---|---|
author | Nilsen, Tom Sunde, Kathrin Larsson, Anders |
author_facet | Nilsen, Tom Sunde, Kathrin Larsson, Anders |
author_sort | Nilsen, Tom |
collection | PubMed |
description | Serum and plasma calprotectin concentration is shown to be elevated when neutrophils are activated, and may therefore be used as a marker for inflammatory diseases. A serum calprotectin immunoassay was developed based on calprotectin values observed in samples from the intensive care unit. The polyclonal avian antibodies were raised and affinity purified with calprotectin antigens. The performance was tested and it was observed that the assay was linear in the range 0.3–24.7 mg/L, the limit of quantitation was observed to be lower than 0.3 mg/L, no antigen excess was observed up to 54 mg/L, all CVs were lower than 1.8 % in the precision study, the calibration curve stability was longer than 6 weeks, and there was no significant interference detected for haemoglobin, intralipid or bilirubin. The serum calprotectin immunoassay presented in this paper performs well within the criteria carefully set from the limited clinical experience obtained in both serum and plasma. In addition it is commutable with Bühlmann MRP8/14 ELISA. |
format | Online Article Text |
id | pubmed-4514941 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45149412015-07-26 A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers Nilsen, Tom Sunde, Kathrin Larsson, Anders J Inflamm (Lond) Research Serum and plasma calprotectin concentration is shown to be elevated when neutrophils are activated, and may therefore be used as a marker for inflammatory diseases. A serum calprotectin immunoassay was developed based on calprotectin values observed in samples from the intensive care unit. The polyclonal avian antibodies were raised and affinity purified with calprotectin antigens. The performance was tested and it was observed that the assay was linear in the range 0.3–24.7 mg/L, the limit of quantitation was observed to be lower than 0.3 mg/L, no antigen excess was observed up to 54 mg/L, all CVs were lower than 1.8 % in the precision study, the calibration curve stability was longer than 6 weeks, and there was no significant interference detected for haemoglobin, intralipid or bilirubin. The serum calprotectin immunoassay presented in this paper performs well within the criteria carefully set from the limited clinical experience obtained in both serum and plasma. In addition it is commutable with Bühlmann MRP8/14 ELISA. BioMed Central 2015-07-25 /pmc/articles/PMC4514941/ /pubmed/26213499 http://dx.doi.org/10.1186/s12950-015-0090-3 Text en © Nilsen et al. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Nilsen, Tom Sunde, Kathrin Larsson, Anders A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers |
title | A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers |
title_full | A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers |
title_fullStr | A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers |
title_full_unstemmed | A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers |
title_short | A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers |
title_sort | new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4514941/ https://www.ncbi.nlm.nih.gov/pubmed/26213499 http://dx.doi.org/10.1186/s12950-015-0090-3 |
work_keys_str_mv | AT nilsentom anewturbidimetricimmunoassayforserumcalprotectinforfullyautomatizedclinicalanalysers AT sundekathrin anewturbidimetricimmunoassayforserumcalprotectinforfullyautomatizedclinicalanalysers AT larssonanders anewturbidimetricimmunoassayforserumcalprotectinforfullyautomatizedclinicalanalysers AT nilsentom newturbidimetricimmunoassayforserumcalprotectinforfullyautomatizedclinicalanalysers AT sundekathrin newturbidimetricimmunoassayforserumcalprotectinforfullyautomatizedclinicalanalysers AT larssonanders newturbidimetricimmunoassayforserumcalprotectinforfullyautomatizedclinicalanalysers |