Cargando…
The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique
BACKGROUND: To investigate differences in the estimated minimum remaining dentin thickness (RDT) between periapical radiographs using the paralleling and parallax technique, after simulated removal of broken instrument from the mesiobuccal (MB) canal of maxillary first molar in virtual simulation mo...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4517344/ https://www.ncbi.nlm.nih.gov/pubmed/26215404 http://dx.doi.org/10.1186/s12903-015-0075-x |
_version_ | 1782383171223945216 |
---|---|
author | Yang, Qian Cheung, Gary Shun-Pan Shen, Ya Huang, Dingming Zhou, Xuedong Gao, Yuan |
author_facet | Yang, Qian Cheung, Gary Shun-Pan Shen, Ya Huang, Dingming Zhou, Xuedong Gao, Yuan |
author_sort | Yang, Qian |
collection | PubMed |
description | BACKGROUND: To investigate differences in the estimated minimum remaining dentin thickness (RDT) between periapical radiographs using the paralleling and parallax technique, after simulated removal of broken instrument from the mesiobuccal (MB) canal of maxillary first molar in virtual simulation model. The 3D measurement was taken as the standard for comparison. METHODS: Thirty-six maxillary first molars were scanned by micro-CT and reconstructed as 3-dimensional (3D) model. A virtual fragment of an instrument was created within the MB canal in software. Removal of the broken instrument was simulated in both the 3D and 2D dataset. Then, the models of all specimens were submitted to 2D and 3D measurements for the lowest (RDT) value in each. Differences in the values between the paralleling and parallax radiographic technique and the 3D-RDT value were analyzed with two-way Analysis of Variance. The Intra-class Correlation Coefficient (ICC) was used to assess consistency of the RDT measurements between the two periapical radiographic and techniques and 3D analysis. RESULTS: There was significant difference between RDT value obtained from the paralleling technique and 3D-RDT. There were no differences between RDT obtained from parallax (angled) technique and 3D-RDT. The ICC of RDT values between paralleling technique and 3D measurement were lower than 0.75. ICC between angled radiographs and 3D technique was close to 0.75. The optimal horizontal angle for the parallax technique was about 21°. CONCLUSIONS: The virtual simulation technique can provide valuable insight into the benefit/risk analysis before removal of a broken instrument. Parallel radiographs overestimate the actual remain dentin thickness in mesiobuccal canals of maxillary first molars, whereas the parallel technique would give a closer estimate to the actual thickness at a projection angle of about 21°. |
format | Online Article Text |
id | pubmed-4517344 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45173442015-07-29 The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique Yang, Qian Cheung, Gary Shun-Pan Shen, Ya Huang, Dingming Zhou, Xuedong Gao, Yuan BMC Oral Health Research Article BACKGROUND: To investigate differences in the estimated minimum remaining dentin thickness (RDT) between periapical radiographs using the paralleling and parallax technique, after simulated removal of broken instrument from the mesiobuccal (MB) canal of maxillary first molar in virtual simulation model. The 3D measurement was taken as the standard for comparison. METHODS: Thirty-six maxillary first molars were scanned by micro-CT and reconstructed as 3-dimensional (3D) model. A virtual fragment of an instrument was created within the MB canal in software. Removal of the broken instrument was simulated in both the 3D and 2D dataset. Then, the models of all specimens were submitted to 2D and 3D measurements for the lowest (RDT) value in each. Differences in the values between the paralleling and parallax radiographic technique and the 3D-RDT value were analyzed with two-way Analysis of Variance. The Intra-class Correlation Coefficient (ICC) was used to assess consistency of the RDT measurements between the two periapical radiographic and techniques and 3D analysis. RESULTS: There was significant difference between RDT value obtained from the paralleling technique and 3D-RDT. There were no differences between RDT obtained from parallax (angled) technique and 3D-RDT. The ICC of RDT values between paralleling technique and 3D measurement were lower than 0.75. ICC between angled radiographs and 3D technique was close to 0.75. The optimal horizontal angle for the parallax technique was about 21°. CONCLUSIONS: The virtual simulation technique can provide valuable insight into the benefit/risk analysis before removal of a broken instrument. Parallel radiographs overestimate the actual remain dentin thickness in mesiobuccal canals of maxillary first molars, whereas the parallel technique would give a closer estimate to the actual thickness at a projection angle of about 21°. BioMed Central 2015-07-28 /pmc/articles/PMC4517344/ /pubmed/26215404 http://dx.doi.org/10.1186/s12903-015-0075-x Text en © Yang et al. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Yang, Qian Cheung, Gary Shun-Pan Shen, Ya Huang, Dingming Zhou, Xuedong Gao, Yuan The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique |
title | The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique |
title_full | The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique |
title_fullStr | The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique |
title_full_unstemmed | The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique |
title_short | The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique |
title_sort | remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4517344/ https://www.ncbi.nlm.nih.gov/pubmed/26215404 http://dx.doi.org/10.1186/s12903-015-0075-x |
work_keys_str_mv | AT yangqian theremainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT cheunggaryshunpan theremainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT shenya theremainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT huangdingming theremainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT zhouxuedong theremainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT gaoyuan theremainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT yangqian remainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT cheunggaryshunpan remainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT shenya remainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT huangdingming remainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT zhouxuedong remainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique AT gaoyuan remainingdentinthicknessinvestigationoftheattempttoremovebrokeninstrumentfrommesiobuccalcanalsofmaxillaryfirstmolarswithvirtualsimulationtechnique |