Cargando…
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO(4)/acetonitrile...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4518099/ https://www.ncbi.nlm.nih.gov/pubmed/26330859 |
_version_ | 1782383281354833920 |
---|---|
author | Ciltas, Ulvihan Yilmaz, Bilal Kaban, Selcuk Akcay, Bilge Kaan Nazik, Gulsah |
author_facet | Ciltas, Ulvihan Yilmaz, Bilal Kaban, Selcuk Akcay, Bilge Kaan Nazik, Gulsah |
author_sort | Ciltas, Ulvihan |
collection | PubMed |
description | In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO(4)/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1 )and 2-20 μg mL(-1 ) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. |
format | Online Article Text |
id | pubmed-4518099 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-45180992015-09-01 Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum Ciltas, Ulvihan Yilmaz, Bilal Kaban, Selcuk Akcay, Bilge Kaan Nazik, Gulsah Iran J Pharm Res Original Article In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO(4)/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1 )and 2-20 μg mL(-1 ) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. Shaheed Beheshti University of Medical Sciences 2015 /pmc/articles/PMC4518099/ /pubmed/26330859 Text en © 2015 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ciltas, Ulvihan Yilmaz, Bilal Kaban, Selcuk Akcay, Bilge Kaan Nazik, Gulsah Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum |
title | Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum |
title_full | Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum |
title_fullStr | Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum |
title_full_unstemmed | Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum |
title_short | Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum |
title_sort | square wave voltammetric determination of diclofenac in pharmaceutical preparations and human serum |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4518099/ https://www.ncbi.nlm.nih.gov/pubmed/26330859 |
work_keys_str_mv | AT ciltasulvihan squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum AT yilmazbilal squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum AT kabanselcuk squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum AT akcaybilgekaan squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum AT nazikgulsah squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum |