Cargando…

Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum

In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO(4)/acetonitrile...

Descripción completa

Detalles Bibliográficos
Autores principales: Ciltas, Ulvihan, Yilmaz, Bilal, Kaban, Selcuk, Akcay, Bilge Kaan, Nazik, Gulsah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shaheed Beheshti University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4518099/
https://www.ncbi.nlm.nih.gov/pubmed/26330859
_version_ 1782383281354833920
author Ciltas, Ulvihan
Yilmaz, Bilal
Kaban, Selcuk
Akcay, Bilge Kaan
Nazik, Gulsah
author_facet Ciltas, Ulvihan
Yilmaz, Bilal
Kaban, Selcuk
Akcay, Bilge Kaan
Nazik, Gulsah
author_sort Ciltas, Ulvihan
collection PubMed
description In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO(4)/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1 )and 2-20 μg mL(-1 ) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum.
format Online
Article
Text
id pubmed-4518099
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Shaheed Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-45180992015-09-01 Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum Ciltas, Ulvihan Yilmaz, Bilal Kaban, Selcuk Akcay, Bilge Kaan Nazik, Gulsah Iran J Pharm Res Original Article In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO(4)/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1 )and 2-20 μg mL(-1 ) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. Shaheed Beheshti University of Medical Sciences 2015 /pmc/articles/PMC4518099/ /pubmed/26330859 Text en © 2015 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ciltas, Ulvihan
Yilmaz, Bilal
Kaban, Selcuk
Akcay, Bilge Kaan
Nazik, Gulsah
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
title Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
title_full Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
title_fullStr Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
title_full_unstemmed Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
title_short Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
title_sort square wave voltammetric determination of diclofenac in pharmaceutical preparations and human serum
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4518099/
https://www.ncbi.nlm.nih.gov/pubmed/26330859
work_keys_str_mv AT ciltasulvihan squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
AT yilmazbilal squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
AT kabanselcuk squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
AT akcaybilgekaan squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
AT nazikgulsah squarewavevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum