Cargando…

Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy

OBJECTIVES: To evaluate the effects of mean heart rate (HR) and heart rate variation (HRV) on image quality and diagnostic accuracy of prospectively ECG-triggered sequential dual-source coronary CT angiography (CCTA) in patients with atrial fibrillation (AF). METHODS: Eighty-five patients (49 women,...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Lin, Xu, Lei, Schoepf, U. Joseph, Wichmann, Julian L., Fox, Mary A., Yan, Jing, Fan, Zhanming, Zhang, Zhaoqi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4519310/
https://www.ncbi.nlm.nih.gov/pubmed/26221952
http://dx.doi.org/10.1371/journal.pone.0134194
_version_ 1782383494839664640
author Yang, Lin
Xu, Lei
Schoepf, U. Joseph
Wichmann, Julian L.
Fox, Mary A.
Yan, Jing
Fan, Zhanming
Zhang, Zhaoqi
author_facet Yang, Lin
Xu, Lei
Schoepf, U. Joseph
Wichmann, Julian L.
Fox, Mary A.
Yan, Jing
Fan, Zhanming
Zhang, Zhaoqi
author_sort Yang, Lin
collection PubMed
description OBJECTIVES: To evaluate the effects of mean heart rate (HR) and heart rate variation (HRV) on image quality and diagnostic accuracy of prospectively ECG-triggered sequential dual-source coronary CT angiography (CCTA) in patients with atrial fibrillation (AF). METHODS: Eighty-five patients (49 women, 36 men; mean age 62.1±9.5 years) with persistent AF underwent prospectively ECG-triggered sequential second-generation dual-source CCTA. Tube current and voltage were adjusted according to body mass index (BMI) and iterative reconstruction was used. Image quality of coronary segments (four-point scale) and presence of significant stenosis (>50%) were evaluated. Diagnostic accuracy was analyzed in 30 of the 85 patients who underwent additional invasive coronary angiography (ICA). RESULTS: Only 8 of 1102 (0.7%) segments demonstrated poor image quality. No significant impact on image quality was found for mean HR (94.9±21.8 bpm; r=0.034, p=0.758; F=0.413, p=0.663) or HRV (67.5±22.8 bpm; r=0.097, p=0.377; F=0.111, p=0.895). On per-segment analysis, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 89.7% (26/29), 99.4% (355/357), 92.9% (26/28), and 99.2% (355/358), respectively, with excellent correlation (kappa=0.91) with ICA. Mean effective dose was 3.3±1.0 mSv. CONCLUSIONS: Prospectively ECG-triggered sequential dual-source CCTA provides diagnostic image quality and good diagnostic accuracy for detection of coronary stenosis in AF patients without significant influence by HR or HRV.
format Online
Article
Text
id pubmed-4519310
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45193102015-07-31 Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy Yang, Lin Xu, Lei Schoepf, U. Joseph Wichmann, Julian L. Fox, Mary A. Yan, Jing Fan, Zhanming Zhang, Zhaoqi PLoS One Research Article OBJECTIVES: To evaluate the effects of mean heart rate (HR) and heart rate variation (HRV) on image quality and diagnostic accuracy of prospectively ECG-triggered sequential dual-source coronary CT angiography (CCTA) in patients with atrial fibrillation (AF). METHODS: Eighty-five patients (49 women, 36 men; mean age 62.1±9.5 years) with persistent AF underwent prospectively ECG-triggered sequential second-generation dual-source CCTA. Tube current and voltage were adjusted according to body mass index (BMI) and iterative reconstruction was used. Image quality of coronary segments (four-point scale) and presence of significant stenosis (>50%) were evaluated. Diagnostic accuracy was analyzed in 30 of the 85 patients who underwent additional invasive coronary angiography (ICA). RESULTS: Only 8 of 1102 (0.7%) segments demonstrated poor image quality. No significant impact on image quality was found for mean HR (94.9±21.8 bpm; r=0.034, p=0.758; F=0.413, p=0.663) or HRV (67.5±22.8 bpm; r=0.097, p=0.377; F=0.111, p=0.895). On per-segment analysis, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 89.7% (26/29), 99.4% (355/357), 92.9% (26/28), and 99.2% (355/358), respectively, with excellent correlation (kappa=0.91) with ICA. Mean effective dose was 3.3±1.0 mSv. CONCLUSIONS: Prospectively ECG-triggered sequential dual-source CCTA provides diagnostic image quality and good diagnostic accuracy for detection of coronary stenosis in AF patients without significant influence by HR or HRV. Public Library of Science 2015-07-29 /pmc/articles/PMC4519310/ /pubmed/26221952 http://dx.doi.org/10.1371/journal.pone.0134194 Text en © 2015 Yang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Yang, Lin
Xu, Lei
Schoepf, U. Joseph
Wichmann, Julian L.
Fox, Mary A.
Yan, Jing
Fan, Zhanming
Zhang, Zhaoqi
Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy
title Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy
title_full Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy
title_fullStr Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy
title_full_unstemmed Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy
title_short Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy
title_sort prospectively ecg-triggered sequential dual-source coronary ct angiography in patients with atrial fibrillation: influence of heart rate on image quality and evaluation of diagnostic accuracy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4519310/
https://www.ncbi.nlm.nih.gov/pubmed/26221952
http://dx.doi.org/10.1371/journal.pone.0134194
work_keys_str_mv AT yanglin prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy
AT xulei prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy
AT schoepfujoseph prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy
AT wichmannjulianl prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy
AT foxmarya prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy
AT yanjing prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy
AT fanzhanming prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy
AT zhangzhaoqi prospectivelyecgtriggeredsequentialdualsourcecoronaryctangiographyinpatientswithatrialfibrillationinfluenceofheartrateonimagequalityandevaluationofdiagnosticaccuracy