Cargando…

VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance

VibraTip™ was selected by the Medical Technologies Advisory Committee (MTAC) to undergo evaluation through the National Institute for Health and Care Excellence (NICE). VibraTip™ provides a vibratory stimulus for the purpose of detecting diabetic peripheral neuropathy (DPN) in patients with type 1 o...

Descripción completa

Detalles Bibliográficos
Autores principales: Willits, Iain, Cole, Helen, Jones, Roseanne, Dimmock, Paul, Arber, Mick, Craig, Joyce, Sims, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4519632/
https://www.ncbi.nlm.nih.gov/pubmed/26093645
http://dx.doi.org/10.1007/s40258-015-0181-6
_version_ 1782383528940404736
author Willits, Iain
Cole, Helen
Jones, Roseanne
Dimmock, Paul
Arber, Mick
Craig, Joyce
Sims, Andrew
author_facet Willits, Iain
Cole, Helen
Jones, Roseanne
Dimmock, Paul
Arber, Mick
Craig, Joyce
Sims, Andrew
author_sort Willits, Iain
collection PubMed
description VibraTip™ was selected by the Medical Technologies Advisory Committee (MTAC) to undergo evaluation through the National Institute for Health and Care Excellence (NICE). VibraTip™ provides a vibratory stimulus for the purpose of detecting diabetic peripheral neuropathy (DPN) in patients with type 1 or 2 diabetes mellitus, and is intended to replace the current practice of using the 128 Hz tuning fork or 10 g monofilament (comparators). The sponsor (McCallan Medical) provided clinical and economic submissions which were evaluated by an External Assessment Centre (EAC). Of six diagnostic studies identified, the EAC considered that only one was directly relevant to the assessment. This study indicated VibraTip™ had a sensitivity of 0.79 (95 % CI 0.69–0.90) and specificity of 0.82 (95 % CI 0.74–0.90) for DPN using a neurothesiometer at 25 V as a reference standard. This was non-inferior to the comparators, but the sample size (n = 141) was too small to draw unequivocal conclusions and it is unclear how generalisable results were to clinical practice. The sponsor presented a de facto cost-minimisation model that in the base case showed minimal cost savings and, in sensitivity analysis which assumed diagnostic superiority of VibraTip™, showed large savings. The EAC appraised this model and concluded it was flawed as it was not evidence based and costs were likely to be unrealistic. The MTAC considered that the technology showed promise but decided the case for adoption was not proven, and therefore made a research recommendation as is reflected in NICE Medical Technology Guidance 22.
format Online
Article
Text
id pubmed-4519632
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-45196322015-08-03 VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance Willits, Iain Cole, Helen Jones, Roseanne Dimmock, Paul Arber, Mick Craig, Joyce Sims, Andrew Appl Health Econ Health Policy Review Article VibraTip™ was selected by the Medical Technologies Advisory Committee (MTAC) to undergo evaluation through the National Institute for Health and Care Excellence (NICE). VibraTip™ provides a vibratory stimulus for the purpose of detecting diabetic peripheral neuropathy (DPN) in patients with type 1 or 2 diabetes mellitus, and is intended to replace the current practice of using the 128 Hz tuning fork or 10 g monofilament (comparators). The sponsor (McCallan Medical) provided clinical and economic submissions which were evaluated by an External Assessment Centre (EAC). Of six diagnostic studies identified, the EAC considered that only one was directly relevant to the assessment. This study indicated VibraTip™ had a sensitivity of 0.79 (95 % CI 0.69–0.90) and specificity of 0.82 (95 % CI 0.74–0.90) for DPN using a neurothesiometer at 25 V as a reference standard. This was non-inferior to the comparators, but the sample size (n = 141) was too small to draw unequivocal conclusions and it is unclear how generalisable results were to clinical practice. The sponsor presented a de facto cost-minimisation model that in the base case showed minimal cost savings and, in sensitivity analysis which assumed diagnostic superiority of VibraTip™, showed large savings. The EAC appraised this model and concluded it was flawed as it was not evidence based and costs were likely to be unrealistic. The MTAC considered that the technology showed promise but decided the case for adoption was not proven, and therefore made a research recommendation as is reflected in NICE Medical Technology Guidance 22. Springer International Publishing 2015-06-21 2015 /pmc/articles/PMC4519632/ /pubmed/26093645 http://dx.doi.org/10.1007/s40258-015-0181-6 Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review Article
Willits, Iain
Cole, Helen
Jones, Roseanne
Dimmock, Paul
Arber, Mick
Craig, Joyce
Sims, Andrew
VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance
title VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance
title_full VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance
title_fullStr VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance
title_full_unstemmed VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance
title_short VibraTip™ for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance
title_sort vibratip™ for testing vibration perception to detect diabetic peripheral neuropathy: a nice medical technology guidance
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4519632/
https://www.ncbi.nlm.nih.gov/pubmed/26093645
http://dx.doi.org/10.1007/s40258-015-0181-6
work_keys_str_mv AT willitsiain vibratipfortestingvibrationperceptiontodetectdiabeticperipheralneuropathyanicemedicaltechnologyguidance
AT colehelen vibratipfortestingvibrationperceptiontodetectdiabeticperipheralneuropathyanicemedicaltechnologyguidance
AT jonesroseanne vibratipfortestingvibrationperceptiontodetectdiabeticperipheralneuropathyanicemedicaltechnologyguidance
AT dimmockpaul vibratipfortestingvibrationperceptiontodetectdiabeticperipheralneuropathyanicemedicaltechnologyguidance
AT arbermick vibratipfortestingvibrationperceptiontodetectdiabeticperipheralneuropathyanicemedicaltechnologyguidance
AT craigjoyce vibratipfortestingvibrationperceptiontodetectdiabeticperipheralneuropathyanicemedicaltechnologyguidance
AT simsandrew vibratipfortestingvibrationperceptiontodetectdiabeticperipheralneuropathyanicemedicaltechnologyguidance