Cargando…
Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report()
Dislocation of the polyethylene component in knee arthroplasty is a rare complication. The main triggering factor is failure of the locking mechanism, which may result from technical errors of insertion, trauma or even implant failure. Here, a case of dislocation of the polyethylene component from t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4519636/ https://www.ncbi.nlm.nih.gov/pubmed/26229887 http://dx.doi.org/10.1016/j.rboe.2014.12.002 |
_version_ | 1782383529862103040 |
---|---|
author | Migon, Eduardo Zaniol de Freitas, Geraldo Luiz Schuck Rodrigues, Marcos Wainberg de Oliveira, Gustavo Kaempf de Almeida, Luis Gustavo Morato Pinto Schwartsmann, Carlos Roberto |
author_facet | Migon, Eduardo Zaniol de Freitas, Geraldo Luiz Schuck Rodrigues, Marcos Wainberg de Oliveira, Gustavo Kaempf de Almeida, Luis Gustavo Morato Pinto Schwartsmann, Carlos Roberto |
author_sort | Migon, Eduardo Zaniol |
collection | PubMed |
description | Dislocation of the polyethylene component in knee arthroplasty is a rare complication. The main triggering factor is failure of the locking mechanism, which may result from technical errors of insertion, trauma or even implant failure. Here, a case of dislocation of the polyethylene component from the tibial base, nine years after revision arthroplasty, is reported. It is believed that this is the first such case reported in the Brazilian literature. |
format | Online Article Text |
id | pubmed-4519636 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-45196362015-07-30 Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() Migon, Eduardo Zaniol de Freitas, Geraldo Luiz Schuck Rodrigues, Marcos Wainberg de Oliveira, Gustavo Kaempf de Almeida, Luis Gustavo Morato Pinto Schwartsmann, Carlos Roberto Rev Bras Ortop Case Report Dislocation of the polyethylene component in knee arthroplasty is a rare complication. The main triggering factor is failure of the locking mechanism, which may result from technical errors of insertion, trauma or even implant failure. Here, a case of dislocation of the polyethylene component from the tibial base, nine years after revision arthroplasty, is reported. It is believed that this is the first such case reported in the Brazilian literature. Elsevier 2014-12-29 /pmc/articles/PMC4519636/ /pubmed/26229887 http://dx.doi.org/10.1016/j.rboe.2014.12.002 Text en © 2014 Sociedade Brasileira de Ortopedia e Traumatologia. Published by Elsevier Editora Ltda. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Migon, Eduardo Zaniol de Freitas, Geraldo Luiz Schuck Rodrigues, Marcos Wainberg de Oliveira, Gustavo Kaempf de Almeida, Luis Gustavo Morato Pinto Schwartsmann, Carlos Roberto Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() |
title | Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() |
title_full | Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() |
title_fullStr | Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() |
title_full_unstemmed | Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() |
title_short | Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() |
title_sort | spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report() |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4519636/ https://www.ncbi.nlm.nih.gov/pubmed/26229887 http://dx.doi.org/10.1016/j.rboe.2014.12.002 |
work_keys_str_mv | AT migoneduardozaniol spontaneousdislocationofthepolyethylenecomponentfollowingkneerevisionarthroplastycasereport AT defreitasgeraldoluizschuck spontaneousdislocationofthepolyethylenecomponentfollowingkneerevisionarthroplastycasereport AT rodriguesmarcoswainberg spontaneousdislocationofthepolyethylenecomponentfollowingkneerevisionarthroplastycasereport AT deoliveiragustavokaempf spontaneousdislocationofthepolyethylenecomponentfollowingkneerevisionarthroplastycasereport AT dealmeidaluisgustavomoratopinto spontaneousdislocationofthepolyethylenecomponentfollowingkneerevisionarthroplastycasereport AT schwartsmanncarlosroberto spontaneousdislocationofthepolyethylenecomponentfollowingkneerevisionarthroplastycasereport |