Cargando…

Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension

BACKGROUND: Cardiac output (CO) is a major diagnostic and prognostic factor in pre-capillary pulmonary hypertension (PH). Reference methods for CO determination, like thermodilution (TD), require invasive procedures and allow only steady-state measurements. The Modelflow (MF) method is an appealing...

Descripción completa

Detalles Bibliográficos
Autores principales: Lador, Frédéric, Hervé, Philippe, Bringard, Aurélien, Günther, Sven, Garcia, Gilles, Savale, Laurent, Ferretti, Guido, Soccal, Paola M., Chemla, Denis, Humbert, Marc, Simonneau, Gérald, Sitbon, Olivier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4520479/
https://www.ncbi.nlm.nih.gov/pubmed/26226280
http://dx.doi.org/10.1371/journal.pone.0134221
_version_ 1782383666755796992
author Lador, Frédéric
Hervé, Philippe
Bringard, Aurélien
Günther, Sven
Garcia, Gilles
Savale, Laurent
Ferretti, Guido
Soccal, Paola M.
Chemla, Denis
Humbert, Marc
Simonneau, Gérald
Sitbon, Olivier
author_facet Lador, Frédéric
Hervé, Philippe
Bringard, Aurélien
Günther, Sven
Garcia, Gilles
Savale, Laurent
Ferretti, Guido
Soccal, Paola M.
Chemla, Denis
Humbert, Marc
Simonneau, Gérald
Sitbon, Olivier
author_sort Lador, Frédéric
collection PubMed
description BACKGROUND: Cardiac output (CO) is a major diagnostic and prognostic factor in pre-capillary pulmonary hypertension (PH). Reference methods for CO determination, like thermodilution (TD), require invasive procedures and allow only steady-state measurements. The Modelflow (MF) method is an appealing technique for this purpose as it allows non-invasive and beat-by-beat determination of CO. METHODS: We aimed to compare CO values obtained simultaneously from non-invasive pulse wave analysis by MF (CO(MF)) and by TD (CO(TD)) to determine its precision and accuracy in pre-capillary PH. The study was performed on 50 patients with pulmonary arterial hypertension (PAH) or chronic thrombo-embolic PH (CTEPH). CO was determined at rest in all patients (n = 50) and during nitric oxide vasoreactivity test, fluid challenge or exercise (n = 48). RESULTS: Baseline CO(MF) and CO(TD) were 6.18 ± 1.95 and 5.46 ± 1.95 L·min(-1), respectively. Accuracy and precision were 0.72 and 1.04 L·min(-1), respectively. Limits of agreement (LoA) ranged from -1.32 to 2.76 L·min(-1). Percentage error (PE) was ±35.7%. Overall sensitivity and specificity of CO(MF) for directional change were 95.2% and 82.4%, (n = 48) and 93.3% and 100% for directional changes during exercise (n = 16), respectively. After application of a correction factor (1.17 ± 0.25), neither proportional nor fixed bias was found for subsequent CO determination (n = 48). Accuracy was -0.03 L·min−1 and precision 0.61 L·min(−1). LoA ranged from -1.23 to 1.17 L·min(−1) and PE was ±19.8%. CONCLUSIONS: After correction against a reference method, MF is precise and accurate enough to determine absolute values and beat-by-beat relative changes of CO in pre-capillary PH.
format Online
Article
Text
id pubmed-4520479
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45204792015-08-06 Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension Lador, Frédéric Hervé, Philippe Bringard, Aurélien Günther, Sven Garcia, Gilles Savale, Laurent Ferretti, Guido Soccal, Paola M. Chemla, Denis Humbert, Marc Simonneau, Gérald Sitbon, Olivier PLoS One Research Article BACKGROUND: Cardiac output (CO) is a major diagnostic and prognostic factor in pre-capillary pulmonary hypertension (PH). Reference methods for CO determination, like thermodilution (TD), require invasive procedures and allow only steady-state measurements. The Modelflow (MF) method is an appealing technique for this purpose as it allows non-invasive and beat-by-beat determination of CO. METHODS: We aimed to compare CO values obtained simultaneously from non-invasive pulse wave analysis by MF (CO(MF)) and by TD (CO(TD)) to determine its precision and accuracy in pre-capillary PH. The study was performed on 50 patients with pulmonary arterial hypertension (PAH) or chronic thrombo-embolic PH (CTEPH). CO was determined at rest in all patients (n = 50) and during nitric oxide vasoreactivity test, fluid challenge or exercise (n = 48). RESULTS: Baseline CO(MF) and CO(TD) were 6.18 ± 1.95 and 5.46 ± 1.95 L·min(-1), respectively. Accuracy and precision were 0.72 and 1.04 L·min(-1), respectively. Limits of agreement (LoA) ranged from -1.32 to 2.76 L·min(-1). Percentage error (PE) was ±35.7%. Overall sensitivity and specificity of CO(MF) for directional change were 95.2% and 82.4%, (n = 48) and 93.3% and 100% for directional changes during exercise (n = 16), respectively. After application of a correction factor (1.17 ± 0.25), neither proportional nor fixed bias was found for subsequent CO determination (n = 48). Accuracy was -0.03 L·min−1 and precision 0.61 L·min(−1). LoA ranged from -1.23 to 1.17 L·min(−1) and PE was ±19.8%. CONCLUSIONS: After correction against a reference method, MF is precise and accurate enough to determine absolute values and beat-by-beat relative changes of CO in pre-capillary PH. Public Library of Science 2015-07-30 /pmc/articles/PMC4520479/ /pubmed/26226280 http://dx.doi.org/10.1371/journal.pone.0134221 Text en © 2015 Lador et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lador, Frédéric
Hervé, Philippe
Bringard, Aurélien
Günther, Sven
Garcia, Gilles
Savale, Laurent
Ferretti, Guido
Soccal, Paola M.
Chemla, Denis
Humbert, Marc
Simonneau, Gérald
Sitbon, Olivier
Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension
title Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension
title_full Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension
title_fullStr Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension
title_full_unstemmed Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension
title_short Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension
title_sort non-invasive determination of cardiac output in pre-capillary pulmonary hypertension
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4520479/
https://www.ncbi.nlm.nih.gov/pubmed/26226280
http://dx.doi.org/10.1371/journal.pone.0134221
work_keys_str_mv AT ladorfrederic noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT hervephilippe noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT bringardaurelien noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT gunthersven noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT garciagilles noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT savalelaurent noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT ferrettiguido noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT soccalpaolam noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT chemladenis noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT humbertmarc noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT simonneaugerald noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension
AT sitbonolivier noninvasivedeterminationofcardiacoutputinprecapillarypulmonaryhypertension