Cargando…

Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma

BACKGROUND: Recent studies have demonstrated equal quality of targeted next generation sequencing (NGS) compared to Sanger Sequencing. Whereas these novel sequencing processes have a validated robust performance, choice of enrichment method and different available bioinformatic software as reliable...

Descripción completa

Detalles Bibliográficos
Autores principales: Crona, Joakim, Ljungström, Viktor, Welin, Staffan, Walz, Martin K., Hellman, Per, Björklund, Peyman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521794/
https://www.ncbi.nlm.nih.gov/pubmed/26230854
http://dx.doi.org/10.1371/journal.pone.0133210
_version_ 1782383857477091328
author Crona, Joakim
Ljungström, Viktor
Welin, Staffan
Walz, Martin K.
Hellman, Per
Björklund, Peyman
author_facet Crona, Joakim
Ljungström, Viktor
Welin, Staffan
Walz, Martin K.
Hellman, Per
Björklund, Peyman
author_sort Crona, Joakim
collection PubMed
description BACKGROUND: Recent studies have demonstrated equal quality of targeted next generation sequencing (NGS) compared to Sanger Sequencing. Whereas these novel sequencing processes have a validated robust performance, choice of enrichment method and different available bioinformatic software as reliable analysis tool needs to be further investigated in a diagnostic setting. METHODS: DNA from 21 patients with genetic variants in SDHB, VHL, EPAS1, RET, (n=17) or clinical criteria of NF1 syndrome (n=4) were included. Targeted NGS was performed using Truseq custom amplicon enrichment sequenced on an Illumina MiSEQ instrument. Results were analysed in parallel using three different bioinformatics pipelines; (1) Commercially available MiSEQ Reporter, fully automatized and integrated software, (2) CLC Genomics Workbench, graphical interface based software, also commercially available, and ICP (3) an in-house scripted custom bioinformatic tool. RESULTS: A tenfold read coverage was achieved in between 95-98% of targeted bases. All workflows had alignment of reads to SDHA and NF1 pseudogenes. Compared to Sanger sequencing, variant calling revealed a sensitivity ranging from 83 to 100% and a specificity of 99.9-100%. Only MiSEQ reporter identified all pathogenic variants in both sequencing runs. CONCLUSIONS: We conclude that targeted next generation sequencing have equal quality compared to Sanger sequencing. Enrichment specificity and the bioinformatic performance need to be carefully assessed in a diagnostic setting. As acceptable accuracy was noted for a fully automated bioinformatic workflow, we suggest that processing of NGS data could be performed without expert bioinformatics skills utilizing already existing commercially available bioinformatics tools.
format Online
Article
Text
id pubmed-4521794
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45217942015-08-06 Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma Crona, Joakim Ljungström, Viktor Welin, Staffan Walz, Martin K. Hellman, Per Björklund, Peyman PLoS One Research Article BACKGROUND: Recent studies have demonstrated equal quality of targeted next generation sequencing (NGS) compared to Sanger Sequencing. Whereas these novel sequencing processes have a validated robust performance, choice of enrichment method and different available bioinformatic software as reliable analysis tool needs to be further investigated in a diagnostic setting. METHODS: DNA from 21 patients with genetic variants in SDHB, VHL, EPAS1, RET, (n=17) or clinical criteria of NF1 syndrome (n=4) were included. Targeted NGS was performed using Truseq custom amplicon enrichment sequenced on an Illumina MiSEQ instrument. Results were analysed in parallel using three different bioinformatics pipelines; (1) Commercially available MiSEQ Reporter, fully automatized and integrated software, (2) CLC Genomics Workbench, graphical interface based software, also commercially available, and ICP (3) an in-house scripted custom bioinformatic tool. RESULTS: A tenfold read coverage was achieved in between 95-98% of targeted bases. All workflows had alignment of reads to SDHA and NF1 pseudogenes. Compared to Sanger sequencing, variant calling revealed a sensitivity ranging from 83 to 100% and a specificity of 99.9-100%. Only MiSEQ reporter identified all pathogenic variants in both sequencing runs. CONCLUSIONS: We conclude that targeted next generation sequencing have equal quality compared to Sanger sequencing. Enrichment specificity and the bioinformatic performance need to be carefully assessed in a diagnostic setting. As acceptable accuracy was noted for a fully automated bioinformatic workflow, we suggest that processing of NGS data could be performed without expert bioinformatics skills utilizing already existing commercially available bioinformatics tools. Public Library of Science 2015-07-31 /pmc/articles/PMC4521794/ /pubmed/26230854 http://dx.doi.org/10.1371/journal.pone.0133210 Text en © 2015 Crona et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Crona, Joakim
Ljungström, Viktor
Welin, Staffan
Walz, Martin K.
Hellman, Per
Björklund, Peyman
Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma
title Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma
title_full Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma
title_fullStr Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma
title_full_unstemmed Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma
title_short Bioinformatic Challenges in Clinical Diagnostic Application of Targeted Next Generation Sequencing: Experience from Pheochromocytoma
title_sort bioinformatic challenges in clinical diagnostic application of targeted next generation sequencing: experience from pheochromocytoma
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521794/
https://www.ncbi.nlm.nih.gov/pubmed/26230854
http://dx.doi.org/10.1371/journal.pone.0133210
work_keys_str_mv AT cronajoakim bioinformaticchallengesinclinicaldiagnosticapplicationoftargetednextgenerationsequencingexperiencefrompheochromocytoma
AT ljungstromviktor bioinformaticchallengesinclinicaldiagnosticapplicationoftargetednextgenerationsequencingexperiencefrompheochromocytoma
AT welinstaffan bioinformaticchallengesinclinicaldiagnosticapplicationoftargetednextgenerationsequencingexperiencefrompheochromocytoma
AT walzmartink bioinformaticchallengesinclinicaldiagnosticapplicationoftargetednextgenerationsequencingexperiencefrompheochromocytoma
AT hellmanper bioinformaticchallengesinclinicaldiagnosticapplicationoftargetednextgenerationsequencingexperiencefrompheochromocytoma
AT bjorklundpeyman bioinformaticchallengesinclinicaldiagnosticapplicationoftargetednextgenerationsequencingexperiencefrompheochromocytoma