Cargando…

Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes

PURPOSE: To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS: Twenty-seven eyes of 27 patients with...

Descripción completa

Detalles Bibliográficos
Autores principales: Loscos-Arenas, Jordi, Parera-Arranz, Angels, Romera-Romera, Pau, Castellvi-Manent, Jordi, Sabala-Llopart, Antoni, de la Cámara-Hermoso, Julio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Raven Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521906/
https://www.ncbi.nlm.nih.gov/pubmed/25836660
http://dx.doi.org/10.1097/IJG.0000000000000253
_version_ 1782383881786228736
author Loscos-Arenas, Jordi
Parera-Arranz, Angels
Romera-Romera, Pau
Castellvi-Manent, Jordi
Sabala-Llopart, Antoni
de la Cámara-Hermoso, Julio
author_facet Loscos-Arenas, Jordi
Parera-Arranz, Angels
Romera-Romera, Pau
Castellvi-Manent, Jordi
Sabala-Llopart, Antoni
de la Cámara-Hermoso, Julio
author_sort Loscos-Arenas, Jordi
collection PubMed
description PURPOSE: To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS: Twenty-seven eyes of 27 patients with open-angle glaucoma, who underwent DS with an Esnoper-Clip implant, were included in this study. All patients were followed up after 12 months. RESULTS: A significant decrease in intraocular pressure was observed after surgery, changing from a preoperative mean of 26.6±5.2 mm Hg to a postoperative mean of 15.3±5 mm Hg (P<0.001) at 12 months. There was also a significant reduction in the number of glaucoma drugs needed, varying from 2.5 per patient to 0.3 (P<0.001) 1 year after surgery. The main intrascleral lake height and volume at 12 months was 0.7±0.1 mm and 3.9±1.3 mm(3), respectively. No intraoperative complications occurred. The main postoperative complications were a positive Seidel test result at 24 hours in 2 eyes (7.4%), hyphema in 2 eyes (7.4%), and choroidal detachment in 1 eye (3.7%). All these complications resolved successfully. The need for additional mitomycin-C injections was recorded in 4 eyes (14.8%), twice in 2 of them. Twelve eyes (44.4%) underwent postsurgical Nd:YAG laser goniopuncture with a mean time between surgery and this procedure of 4.3 months. Mean intraocular pressure after Nd:YAG laser goniopuncture decreased from 19.2 to 15.5 mm Hg (P<0.001). CONCLUSION: DS with an uveoscleral hema implant (Esnoper-Clip) is a safe and effective technique for the management of open-angle glaucoma.
format Online
Article
Text
id pubmed-4521906
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Raven Press
record_format MEDLINE/PubMed
spelling pubmed-45219062015-08-11 Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes Loscos-Arenas, Jordi Parera-Arranz, Angels Romera-Romera, Pau Castellvi-Manent, Jordi Sabala-Llopart, Antoni de la Cámara-Hermoso, Julio J Glaucoma Original Studies PURPOSE: To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS: Twenty-seven eyes of 27 patients with open-angle glaucoma, who underwent DS with an Esnoper-Clip implant, were included in this study. All patients were followed up after 12 months. RESULTS: A significant decrease in intraocular pressure was observed after surgery, changing from a preoperative mean of 26.6±5.2 mm Hg to a postoperative mean of 15.3±5 mm Hg (P<0.001) at 12 months. There was also a significant reduction in the number of glaucoma drugs needed, varying from 2.5 per patient to 0.3 (P<0.001) 1 year after surgery. The main intrascleral lake height and volume at 12 months was 0.7±0.1 mm and 3.9±1.3 mm(3), respectively. No intraoperative complications occurred. The main postoperative complications were a positive Seidel test result at 24 hours in 2 eyes (7.4%), hyphema in 2 eyes (7.4%), and choroidal detachment in 1 eye (3.7%). All these complications resolved successfully. The need for additional mitomycin-C injections was recorded in 4 eyes (14.8%), twice in 2 of them. Twelve eyes (44.4%) underwent postsurgical Nd:YAG laser goniopuncture with a mean time between surgery and this procedure of 4.3 months. Mean intraocular pressure after Nd:YAG laser goniopuncture decreased from 19.2 to 15.5 mm Hg (P<0.001). CONCLUSION: DS with an uveoscleral hema implant (Esnoper-Clip) is a safe and effective technique for the management of open-angle glaucoma. Raven Press 2015-08 2015-08-05 /pmc/articles/PMC4521906/ /pubmed/25836660 http://dx.doi.org/10.1097/IJG.0000000000000253 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/4.0/.
spellingShingle Original Studies
Loscos-Arenas, Jordi
Parera-Arranz, Angels
Romera-Romera, Pau
Castellvi-Manent, Jordi
Sabala-Llopart, Antoni
de la Cámara-Hermoso, Julio
Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes
title Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes
title_full Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes
title_fullStr Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes
title_full_unstemmed Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes
title_short Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes
title_sort deep sclerectomy with a new nonabsorbable uveoscleral implant (esnoper-clip): 1-year outcomes
topic Original Studies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521906/
https://www.ncbi.nlm.nih.gov/pubmed/25836660
http://dx.doi.org/10.1097/IJG.0000000000000253
work_keys_str_mv AT loscosarenasjordi deepsclerectomywithanewnonabsorbableuveoscleralimplantesnoperclip1yearoutcomes
AT pareraarranzangels deepsclerectomywithanewnonabsorbableuveoscleralimplantesnoperclip1yearoutcomes
AT romeraromerapau deepsclerectomywithanewnonabsorbableuveoscleralimplantesnoperclip1yearoutcomes
AT castellvimanentjordi deepsclerectomywithanewnonabsorbableuveoscleralimplantesnoperclip1yearoutcomes
AT sabalallopartantoni deepsclerectomywithanewnonabsorbableuveoscleralimplantesnoperclip1yearoutcomes
AT delacamarahermosojulio deepsclerectomywithanewnonabsorbableuveoscleralimplantesnoperclip1yearoutcomes