Cargando…

Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography

BACKGROUND: Dangguisu-san (DGSS) has been widely used to treat ecchymosis, blood stagnation and pain resulting from physical shock in Korea. OBJECTIVE: A high-performance liquid chromatography–photodiode array detection (HPLC–PDA) method for simultaneous analysis of nine components, albiflorin (1),...

Descripción completa

Detalles Bibliográficos
Autores principales: Seo, Chang-Seob, Shin, Hyeun-Kyoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4522842/
https://www.ncbi.nlm.nih.gov/pubmed/26246731
http://dx.doi.org/10.4103/0973-1296.160457
_version_ 1782384006070796288
author Seo, Chang-Seob
Shin, Hyeun-Kyoo
author_facet Seo, Chang-Seob
Shin, Hyeun-Kyoo
author_sort Seo, Chang-Seob
collection PubMed
description BACKGROUND: Dangguisu-san (DGSS) has been widely used to treat ecchymosis, blood stagnation and pain resulting from physical shock in Korea. OBJECTIVE: A high-performance liquid chromatography–photodiode array detection (HPLC–PDA) method for simultaneous analysis of nine components, albiflorin (1), paeoniflorin (2), liquiritin (3), nodakenin (4), coumarin (5), liquiritigenin (6), cinnamic acid (7), cinnamaldehyde (8), and glycyrrhizin (9) in DGSS extract has been developed for the first time. MATERIALS AND METHODS: The analytical column for separation of the nine constituents used a Gemini C(18) column kept at 40°C by the gradient elution with 1.0% (v/v) acetic acid in water and 1.0% (v/v) acetic acid in acetonitrile as mobile phase. The flow rate was 1.0 mL/min and the injection volume was 10 μL. RESULTS: Calibration curves of all compounds showed good linearity (r(2) ≥ 0.9999) within the test ranges. The limits of detection and quantification for all analytes were 0.01–0.27 μg/mL and 0.04–0.89 μg/mL, respectively. All recoveries of the nine marker compounds were 96.62–102.47% with relative standard deviations (RSD) <1.72%. The RSDs of intra-day and inter-day precision were <1.32% and 1.61%, respectively. The amounts of the nine marker components ranged from 0.10 mg/g to 13.71 mg/g. CONCLUSION: The developed and validated HPLC–PDA method may help for the quality control of DGSS.
format Online
Article
Text
id pubmed-4522842
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-45228422015-08-05 Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography Seo, Chang-Seob Shin, Hyeun-Kyoo Pharmacogn Mag Original Article BACKGROUND: Dangguisu-san (DGSS) has been widely used to treat ecchymosis, blood stagnation and pain resulting from physical shock in Korea. OBJECTIVE: A high-performance liquid chromatography–photodiode array detection (HPLC–PDA) method for simultaneous analysis of nine components, albiflorin (1), paeoniflorin (2), liquiritin (3), nodakenin (4), coumarin (5), liquiritigenin (6), cinnamic acid (7), cinnamaldehyde (8), and glycyrrhizin (9) in DGSS extract has been developed for the first time. MATERIALS AND METHODS: The analytical column for separation of the nine constituents used a Gemini C(18) column kept at 40°C by the gradient elution with 1.0% (v/v) acetic acid in water and 1.0% (v/v) acetic acid in acetonitrile as mobile phase. The flow rate was 1.0 mL/min and the injection volume was 10 μL. RESULTS: Calibration curves of all compounds showed good linearity (r(2) ≥ 0.9999) within the test ranges. The limits of detection and quantification for all analytes were 0.01–0.27 μg/mL and 0.04–0.89 μg/mL, respectively. All recoveries of the nine marker compounds were 96.62–102.47% with relative standard deviations (RSD) <1.72%. The RSDs of intra-day and inter-day precision were <1.32% and 1.61%, respectively. The amounts of the nine marker components ranged from 0.10 mg/g to 13.71 mg/g. CONCLUSION: The developed and validated HPLC–PDA method may help for the quality control of DGSS. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4522842/ /pubmed/26246731 http://dx.doi.org/10.4103/0973-1296.160457 Text en Copyright: © Pharmacognosy Magazine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Seo, Chang-Seob
Shin, Hyeun-Kyoo
Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography
title Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography
title_full Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography
title_fullStr Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography
title_full_unstemmed Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography
title_short Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu-san by high-performance liquid chromatography
title_sort simultaneous determination of nine marker compounds in the traditional korean medicine, dangguisu-san by high-performance liquid chromatography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4522842/
https://www.ncbi.nlm.nih.gov/pubmed/26246731
http://dx.doi.org/10.4103/0973-1296.160457
work_keys_str_mv AT seochangseob simultaneousdeterminationofninemarkercompoundsinthetraditionalkoreanmedicinedangguisusanbyhighperformanceliquidchromatography
AT shinhyeunkyoo simultaneousdeterminationofninemarkercompoundsinthetraditionalkoreanmedicinedangguisusanbyhighperformanceliquidchromatography