Cargando…
Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation
BACKGROUND: Few reports from the medical literature have presented severe mesh-related complications following laparoscopic repair of inguinal hernia. One of these complications is being mesh erosion into bowel, resulting in fistulous tract with subsequent abscess formation. CASE PRESENTATION: A 75-...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4524372/ https://www.ncbi.nlm.nih.gov/pubmed/26239722 http://dx.doi.org/10.1186/s12893-015-0070-9 |
_version_ | 1782384181835202560 |
---|---|
author | Degheili, Jad A. Aboul Hosn, Maen El Lakis, Mustapha Hallal, Ali H. |
author_facet | Degheili, Jad A. Aboul Hosn, Maen El Lakis, Mustapha Hallal, Ali H. |
author_sort | Degheili, Jad A. |
collection | PubMed |
description | BACKGROUND: Few reports from the medical literature have presented severe mesh-related complications following laparoscopic repair of inguinal hernia. One of these complications is being mesh erosion into bowel, resulting in fistulous tract with subsequent abscess formation. CASE PRESENTATION: A 75-year-old patient, status post laparoscopic bilateral inguinal hernia repair, and on anticoagulation for dual prosthetic heart valves, presented with a unique case of sigmoid to scrotal fistula, post mesh erosion, resulting in sepsis. The patient presented in septic shock, necessitating an individualized surgical approach. Given the septic picture of our patient, the surgical approach was truncated. Initially the sepsis from the scrotum was drained and debrided. A watermelon seed was noted in the scrotum. After stabilization, the second stage approach was performed, were a laparotomy was performed, followed by division of the sigmoid to internal ring fistula, and reperitonealization of the mesh. Mesh removal was delayed as the risk of bleeding into the peritoneum was high, once anticoagulation needed to be resumed. Because of a persistent wound sinus tract, several months later, the mesh was removed, in a third stage, from an inguinal incision. Albeit meticulous dissection and homeostasis, a postoperative extraperitoneal inguinal hematoma developed, as expected, on day 2, once anticoagulation was resumed. CONCLUSION: Sigmoid to inguinoscrotal fistula is a rare, yet serious, complication of mesh infection and erosion. This can be obviated by preventing serosal tear, and proper peritonealization of the mesh. Fistulectomy alone with primary repair turned out to be a valid approach in our patient. Retaining the mesh could be an alternative for avoiding bleeding in patients on anticoagulation; despite that a persistent indolent infection and sinus tract will necessitate mesh removal afterwards. |
format | Online Article Text |
id | pubmed-4524372 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45243722015-08-05 Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation Degheili, Jad A. Aboul Hosn, Maen El Lakis, Mustapha Hallal, Ali H. BMC Surg Case Report BACKGROUND: Few reports from the medical literature have presented severe mesh-related complications following laparoscopic repair of inguinal hernia. One of these complications is being mesh erosion into bowel, resulting in fistulous tract with subsequent abscess formation. CASE PRESENTATION: A 75-year-old patient, status post laparoscopic bilateral inguinal hernia repair, and on anticoagulation for dual prosthetic heart valves, presented with a unique case of sigmoid to scrotal fistula, post mesh erosion, resulting in sepsis. The patient presented in septic shock, necessitating an individualized surgical approach. Given the septic picture of our patient, the surgical approach was truncated. Initially the sepsis from the scrotum was drained and debrided. A watermelon seed was noted in the scrotum. After stabilization, the second stage approach was performed, were a laparotomy was performed, followed by division of the sigmoid to internal ring fistula, and reperitonealization of the mesh. Mesh removal was delayed as the risk of bleeding into the peritoneum was high, once anticoagulation needed to be resumed. Because of a persistent wound sinus tract, several months later, the mesh was removed, in a third stage, from an inguinal incision. Albeit meticulous dissection and homeostasis, a postoperative extraperitoneal inguinal hematoma developed, as expected, on day 2, once anticoagulation was resumed. CONCLUSION: Sigmoid to inguinoscrotal fistula is a rare, yet serious, complication of mesh infection and erosion. This can be obviated by preventing serosal tear, and proper peritonealization of the mesh. Fistulectomy alone with primary repair turned out to be a valid approach in our patient. Retaining the mesh could be an alternative for avoiding bleeding in patients on anticoagulation; despite that a persistent indolent infection and sinus tract will necessitate mesh removal afterwards. BioMed Central 2015-08-04 /pmc/articles/PMC4524372/ /pubmed/26239722 http://dx.doi.org/10.1186/s12893-015-0070-9 Text en © Degheili et al. 2015 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Degheili, Jad A. Aboul Hosn, Maen El Lakis, Mustapha Hallal, Ali H. Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation |
title | Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation |
title_full | Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation |
title_fullStr | Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation |
title_full_unstemmed | Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation |
title_short | Sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation |
title_sort | sigmoid to scrotal fistula secondary to mesh erosion: a rare complication of inguinal hernia repair in a patient on anticoagulation |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4524372/ https://www.ncbi.nlm.nih.gov/pubmed/26239722 http://dx.doi.org/10.1186/s12893-015-0070-9 |
work_keys_str_mv | AT degheilijada sigmoidtoscrotalfistulasecondarytomesherosionararecomplicationofinguinalherniarepairinapatientonanticoagulation AT aboulhosnmaen sigmoidtoscrotalfistulasecondarytomesherosionararecomplicationofinguinalherniarepairinapatientonanticoagulation AT ellakismustapha sigmoidtoscrotalfistulasecondarytomesherosionararecomplicationofinguinalherniarepairinapatientonanticoagulation AT hallalalih sigmoidtoscrotalfistulasecondarytomesherosionararecomplicationofinguinalherniarepairinapatientonanticoagulation |