Cargando…

Peripapillary choroidal thickness in healthy Turkish subjects

AIM: The objective of the study reported here was to investigate the normal peripapillary choroidal thickness (CT), measured by enhanced depth imaging optical coherence tomography (EDI-OCT), in healthy Turkish volunteers. MATERIALS AND METHODS: In this prospective cross-sectional study, 57 eyes of 5...

Descripción completa

Detalles Bibliográficos
Autores principales: Erbagci, Hulya, Oren, Burak, Okumus, Seydi, Kenan, Serhat, Celemler, Pelin, Erbagci, Ibrahim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4525789/
https://www.ncbi.nlm.nih.gov/pubmed/26257510
http://dx.doi.org/10.2147/OPTH.S79919
_version_ 1782384363520917504
author Erbagci, Hulya
Oren, Burak
Okumus, Seydi
Kenan, Serhat
Celemler, Pelin
Erbagci, Ibrahim
author_facet Erbagci, Hulya
Oren, Burak
Okumus, Seydi
Kenan, Serhat
Celemler, Pelin
Erbagci, Ibrahim
author_sort Erbagci, Hulya
collection PubMed
description AIM: The objective of the study reported here was to investigate the normal peripapillary choroidal thickness (CT), measured by enhanced depth imaging optical coherence tomography (EDI-OCT), in healthy Turkish volunteers. MATERIALS AND METHODS: In this prospective cross-sectional study, 57 eyes of 57 healthy Turkish subjects were enrolled. Each participant underwent a comprehensive ophthalmic examination and peripapillary CT measurement using EDI-OCT. RESULTS: The mean age of the 25 female and 32 male patients in the study was 30.9±10.6 years (range, 18–56 years). The mean peripapillary CT at the superior, inferior, nasal, and temporal sites was 225±57, 183±47, 220±57, and 233±59 μm, respectively. The inferior peripapillary CT value was significantly lower than the peripapillary CT values (P<0.001 for all), whereas no significant differences were found between the superior, nasal, and temporal peripapillary CT values. CONCLUSION: The findings of the study revealed that Turkish people had significantly lower peripapillary CT values in the inferior quadrant than in the superior, nasal, and temporal quadrants.
format Online
Article
Text
id pubmed-4525789
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-45257892015-08-07 Peripapillary choroidal thickness in healthy Turkish subjects Erbagci, Hulya Oren, Burak Okumus, Seydi Kenan, Serhat Celemler, Pelin Erbagci, Ibrahim Clin Ophthalmol Original Research AIM: The objective of the study reported here was to investigate the normal peripapillary choroidal thickness (CT), measured by enhanced depth imaging optical coherence tomography (EDI-OCT), in healthy Turkish volunteers. MATERIALS AND METHODS: In this prospective cross-sectional study, 57 eyes of 57 healthy Turkish subjects were enrolled. Each participant underwent a comprehensive ophthalmic examination and peripapillary CT measurement using EDI-OCT. RESULTS: The mean age of the 25 female and 32 male patients in the study was 30.9±10.6 years (range, 18–56 years). The mean peripapillary CT at the superior, inferior, nasal, and temporal sites was 225±57, 183±47, 220±57, and 233±59 μm, respectively. The inferior peripapillary CT value was significantly lower than the peripapillary CT values (P<0.001 for all), whereas no significant differences were found between the superior, nasal, and temporal peripapillary CT values. CONCLUSION: The findings of the study revealed that Turkish people had significantly lower peripapillary CT values in the inferior quadrant than in the superior, nasal, and temporal quadrants. Dove Medical Press 2015-07-30 /pmc/articles/PMC4525789/ /pubmed/26257510 http://dx.doi.org/10.2147/OPTH.S79919 Text en © 2015 Erbagci et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Erbagci, Hulya
Oren, Burak
Okumus, Seydi
Kenan, Serhat
Celemler, Pelin
Erbagci, Ibrahim
Peripapillary choroidal thickness in healthy Turkish subjects
title Peripapillary choroidal thickness in healthy Turkish subjects
title_full Peripapillary choroidal thickness in healthy Turkish subjects
title_fullStr Peripapillary choroidal thickness in healthy Turkish subjects
title_full_unstemmed Peripapillary choroidal thickness in healthy Turkish subjects
title_short Peripapillary choroidal thickness in healthy Turkish subjects
title_sort peripapillary choroidal thickness in healthy turkish subjects
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4525789/
https://www.ncbi.nlm.nih.gov/pubmed/26257510
http://dx.doi.org/10.2147/OPTH.S79919
work_keys_str_mv AT erbagcihulya peripapillarychoroidalthicknessinhealthyturkishsubjects
AT orenburak peripapillarychoroidalthicknessinhealthyturkishsubjects
AT okumusseydi peripapillarychoroidalthicknessinhealthyturkishsubjects
AT kenanserhat peripapillarychoroidalthicknessinhealthyturkishsubjects
AT celemlerpelin peripapillarychoroidalthicknessinhealthyturkishsubjects
AT erbagciibrahim peripapillarychoroidalthicknessinhealthyturkishsubjects