Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring
The integrated use of optical technologies for patient monitoring is addressed in the framework of time-resolved treatment delivery for scanned ion beam therapy. A software application has been designed to provide the therapy control system (TCS) with a continuous geometrical feedback by processing...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4527457/ https://www.ncbi.nlm.nih.gov/pubmed/24354750 http://dx.doi.org/10.7785/tcrtexpress.2013.600275 |
_version_ | 1782384567885234176 |
---|---|
author | Fattori, G. Saito, N. Seregni, M. Kaderka, R. Pella, A. Constantinescu, A. Riboldi, M. Steidl, P. Cerveri, P. Bert, C. Durante, M. Baroni, G. |
author_facet | Fattori, G. Saito, N. Seregni, M. Kaderka, R. Pella, A. Constantinescu, A. Riboldi, M. Steidl, P. Cerveri, P. Bert, C. Durante, M. Baroni, G. |
author_sort | Fattori, G. |
collection | PubMed |
description | The integrated use of optical technologies for patient monitoring is addressed in the framework of time-resolved treatment delivery for scanned ion beam therapy. A software application has been designed to provide the therapy control system (TCS) with a continuous geometrical feedback by processing the external surrogates tridimensional data, detected in real-time via optical tracking. Conventional procedures for phase-based respiratory phase detection were implemented, as well as the interface to patient specific correlation models, in order to estimate internal tumor motion from surface markers. In this paper, particular attention is dedicated to the quantification of time delays resulting from system integration and its compensation by means of polynomial interpolation in the time domain. Dedicated tests to assess the separate delay contributions due to optical signal processing, digital data transfer to the TCS and passive beam energy modulation actuation have been performed. We report the system technological commissioning activities reporting dose distribution errors in a phantom study, where the treatment of a lung lesion was simulated, with both lateral and range beam position compensation. The zero-delay systems integration with a specific active scanning delivery machine was achieved by tuning the amount of time prediction applied to lateral (14.61 ± 0.98 ms) and depth (34.1 ± 6.29 ms) beam position correction signals, featuring sub-millimeter accuracy in forward estimation. Direct optical target observation and motion phase (MPh) based tumor motion discretization strategies were tested, resulting in −0.3(2.3)% and −1.2(9.3)% median (IQR) percentual relative dose difference with respect to static irradiation, respectively. Results confirm the technical feasibility of the implemented strategy towards 4D treatment delivery, with negligible percentual dose deviations with respect to static irradiation. |
format | Online Article Text |
id | pubmed-4527457 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-45274572015-10-20 Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring Fattori, G. Saito, N. Seregni, M. Kaderka, R. Pella, A. Constantinescu, A. Riboldi, M. Steidl, P. Cerveri, P. Bert, C. Durante, M. Baroni, G. Technol Cancer Res Treat Articles The integrated use of optical technologies for patient monitoring is addressed in the framework of time-resolved treatment delivery for scanned ion beam therapy. A software application has been designed to provide the therapy control system (TCS) with a continuous geometrical feedback by processing the external surrogates tridimensional data, detected in real-time via optical tracking. Conventional procedures for phase-based respiratory phase detection were implemented, as well as the interface to patient specific correlation models, in order to estimate internal tumor motion from surface markers. In this paper, particular attention is dedicated to the quantification of time delays resulting from system integration and its compensation by means of polynomial interpolation in the time domain. Dedicated tests to assess the separate delay contributions due to optical signal processing, digital data transfer to the TCS and passive beam energy modulation actuation have been performed. We report the system technological commissioning activities reporting dose distribution errors in a phantom study, where the treatment of a lung lesion was simulated, with both lateral and range beam position compensation. The zero-delay systems integration with a specific active scanning delivery machine was achieved by tuning the amount of time prediction applied to lateral (14.61 ± 0.98 ms) and depth (34.1 ± 6.29 ms) beam position correction signals, featuring sub-millimeter accuracy in forward estimation. Direct optical target observation and motion phase (MPh) based tumor motion discretization strategies were tested, resulting in −0.3(2.3)% and −1.2(9.3)% median (IQR) percentual relative dose difference with respect to static irradiation, respectively. Results confirm the technical feasibility of the implemented strategy towards 4D treatment delivery, with negligible percentual dose deviations with respect to static irradiation. SAGE Publications 2014-12 /pmc/articles/PMC4527457/ /pubmed/24354750 http://dx.doi.org/10.7785/tcrtexpress.2013.600275 Text en © Adenine Press (2014) http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Articles Fattori, G. Saito, N. Seregni, M. Kaderka, R. Pella, A. Constantinescu, A. Riboldi, M. Steidl, P. Cerveri, P. Bert, C. Durante, M. Baroni, G. Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring |
title | Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring |
title_full | Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring |
title_fullStr | Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring |
title_full_unstemmed | Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring |
title_short | Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring |
title_sort | commissioning of an integrated platform for time-resolved treatment delivery in scanned ion beam therapy by means of optical motion monitoring |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4527457/ https://www.ncbi.nlm.nih.gov/pubmed/24354750 http://dx.doi.org/10.7785/tcrtexpress.2013.600275 |
work_keys_str_mv | AT fattorig commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT saiton commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT seregnim commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT kaderkar commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT pellaa commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT constantinescua commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT riboldim commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT steidlp commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT cerverip commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT bertc commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT durantem commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring AT baronig commissioningofanintegratedplatformfortimeresolvedtreatmentdeliveryinscannedionbeamtherapybymeansofopticalmotionmonitoring |