Cargando…

IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking

The problem addressed here was to obtain optimal and deliverable dynamic multileaf collimator (MLC) leaf sequences from four-dimensional (4D) geometries for dynamic MLC tracking delivery. The envisaged scenario was where respiratory phase and position information of the target was available during t...

Descripción completa

Detalles Bibliográficos
Autores principales: Suh, Yelin, Murray, Walter, Keall, Paul J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4527473/
https://www.ncbi.nlm.nih.gov/pubmed/24354751
http://dx.doi.org/10.7785/tcrtexpress.2013.600276
_version_ 1782384570382942208
author Suh, Yelin
Murray, Walter
Keall, Paul J.
author_facet Suh, Yelin
Murray, Walter
Keall, Paul J.
author_sort Suh, Yelin
collection PubMed
description The problem addressed here was to obtain optimal and deliverable dynamic multileaf collimator (MLC) leaf sequences from four-dimensional (4D) geometries for dynamic MLC tracking delivery. The envisaged scenario was where respiratory phase and position information of the target was available during treatment, from which the optimal treatment plan could be further adapted in real time. A tool for 4D treatment plan optimization was developed that integrates a commercially available treatment planning system and a general-purpose optimization system. The 4D planning method was applied to the 4D computed tomography planning scans of three lung cancer patients. The optimization variables were MLC leaf positions as a function of monitor units and respiratory phase. The objective function was the deformable dose-summed 4D treatment plan score. MLC leaf motion was constrained by the maximum leaf velocity between control points in terms of monitor units for tumor motion parallel to the leaf travel direction and between phases for tumor motion parallel to the leaf travel direction. For comparison and a starting point for the 4D optimization, three-dimensional (3D) optimization was performed on each of the phases. The output of the 4D IMRT planning process is a leaf sequence which is a function of both monitor unit and phase, which can be delivered to a patient whose breathing may vary between the imaging and treatment sessions. The 4D treatment plan score improved during 4D optimization by 34%, 4%, and 50% for Patients A, B, and C, respectively, indicating 4D optimization generated a better 4D treatment plan than the deformable sum of individually optimized phase plans. The dose-volume histograms for each phase remained similar, indicating robustness of the 4D treatment plan to respiratory variations expected during treatment delivery. In summary, 4D optimization for respiratory phase-dependent treatment planning with dynamic MLC motion tracking improved the 4D treatment plan score by 4–50% compared with 3D optimization. The 4D treatment plans had leaf sequences that varied from phase to phase to account for anatomic motion, but showed similar target dose distributions in each phase. The current method could in principle be generalized for use in offline replanning between fractions or for online 4D treatment planning based on 4D cone-beam CT images. Computation time remains a challenge.
format Online
Article
Text
id pubmed-4527473
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-45274732015-10-20 IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking Suh, Yelin Murray, Walter Keall, Paul J. Technol Cancer Res Treat Articles The problem addressed here was to obtain optimal and deliverable dynamic multileaf collimator (MLC) leaf sequences from four-dimensional (4D) geometries for dynamic MLC tracking delivery. The envisaged scenario was where respiratory phase and position information of the target was available during treatment, from which the optimal treatment plan could be further adapted in real time. A tool for 4D treatment plan optimization was developed that integrates a commercially available treatment planning system and a general-purpose optimization system. The 4D planning method was applied to the 4D computed tomography planning scans of three lung cancer patients. The optimization variables were MLC leaf positions as a function of monitor units and respiratory phase. The objective function was the deformable dose-summed 4D treatment plan score. MLC leaf motion was constrained by the maximum leaf velocity between control points in terms of monitor units for tumor motion parallel to the leaf travel direction and between phases for tumor motion parallel to the leaf travel direction. For comparison and a starting point for the 4D optimization, three-dimensional (3D) optimization was performed on each of the phases. The output of the 4D IMRT planning process is a leaf sequence which is a function of both monitor unit and phase, which can be delivered to a patient whose breathing may vary between the imaging and treatment sessions. The 4D treatment plan score improved during 4D optimization by 34%, 4%, and 50% for Patients A, B, and C, respectively, indicating 4D optimization generated a better 4D treatment plan than the deformable sum of individually optimized phase plans. The dose-volume histograms for each phase remained similar, indicating robustness of the 4D treatment plan to respiratory variations expected during treatment delivery. In summary, 4D optimization for respiratory phase-dependent treatment planning with dynamic MLC motion tracking improved the 4D treatment plan score by 4–50% compared with 3D optimization. The 4D treatment plans had leaf sequences that varied from phase to phase to account for anatomic motion, but showed similar target dose distributions in each phase. The current method could in principle be generalized for use in offline replanning between fractions or for online 4D treatment planning based on 4D cone-beam CT images. Computation time remains a challenge. SAGE Publications 2014-12 /pmc/articles/PMC4527473/ /pubmed/24354751 http://dx.doi.org/10.7785/tcrtexpress.2013.600276 Text en © Adenine Press (2014) http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Articles
Suh, Yelin
Murray, Walter
Keall, Paul J.
IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
title IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
title_full IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
title_fullStr IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
title_full_unstemmed IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
title_short IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
title_sort imrt treatment planning on 4d geometries for the era of dynamic mlc tracking
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4527473/
https://www.ncbi.nlm.nih.gov/pubmed/24354751
http://dx.doi.org/10.7785/tcrtexpress.2013.600276
work_keys_str_mv AT suhyelin imrttreatmentplanningon4dgeometriesfortheeraofdynamicmlctracking
AT murraywalter imrttreatmentplanningon4dgeometriesfortheeraofdynamicmlctracking
AT keallpaulj imrttreatmentplanningon4dgeometriesfortheeraofdynamicmlctracking