Cargando…

CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors

Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10[Formula: see text] . CUORE , an array of 988 TeO[Formula: see text] bolometers being commissioned at Laboratori Nazionali del Gran Sasso, features an expected sensitivi...

Descripción completa

Detalles Bibliográficos
Autores principales: Battistelli, E. S., Bellini, F., Bucci, C., Calvo, M., Cardani, L., Casali, N., Castellano, M. G., Colantoni, I., Coppolecchia, A., Cosmelli, C., Cruciani, A., de Bernardis, P., Di Domizio, S., D’Addabbo, A., Martinez, M., Masi, S., Pagnanini, L., Tomei, C., Vignati, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4528268/
https://www.ncbi.nlm.nih.gov/pubmed/26269692
http://dx.doi.org/10.1140/epjc/s10052-015-3575-6
_version_ 1782384660547895296
author Battistelli, E. S.
Bellini, F.
Bucci, C.
Calvo, M.
Cardani, L.
Casali, N.
Castellano, M. G.
Colantoni, I.
Coppolecchia, A.
Cosmelli, C.
Cruciani, A.
de Bernardis, P.
Di Domizio, S.
D’Addabbo, A.
Martinez, M.
Masi, S.
Pagnanini, L.
Tomei, C.
Vignati, M.
author_facet Battistelli, E. S.
Bellini, F.
Bucci, C.
Calvo, M.
Cardani, L.
Casali, N.
Castellano, M. G.
Colantoni, I.
Coppolecchia, A.
Cosmelli, C.
Cruciani, A.
de Bernardis, P.
Di Domizio, S.
D’Addabbo, A.
Martinez, M.
Masi, S.
Pagnanini, L.
Tomei, C.
Vignati, M.
author_sort Battistelli, E. S.
collection PubMed
description Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10[Formula: see text] . CUORE , an array of 988 TeO[Formula: see text] bolometers being commissioned at Laboratori Nazionali del Gran Sasso, features an expected sensitivity of 50–130[Formula: see text] at 90 % C.L. The background is expected to be dominated by [Formula: see text] radioactivity, and can be in principle removed by detecting the small amount of Cherenkov  light emitted by the [Formula: see text] signal. The Cryogenic wide-Area Light Detectors with Excellent Resolution project aims at developing a small prototype experiment consisting of TeO[Formula: see text] bolometers coupled to high-sensitivity light detectors based on kinetic inductance detectors. The R&D is focused on the light detectors in view of the implementation in a next-generation neutrinoless double-beta decay experiment.
format Online
Article
Text
id pubmed-4528268
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-45282682015-08-10 CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors Battistelli, E. S. Bellini, F. Bucci, C. Calvo, M. Cardani, L. Casali, N. Castellano, M. G. Colantoni, I. Coppolecchia, A. Cosmelli, C. Cruciani, A. de Bernardis, P. Di Domizio, S. D’Addabbo, A. Martinez, M. Masi, S. Pagnanini, L. Tomei, C. Vignati, M. Eur Phys J C Part Fields Regular Article - Experimental Physics Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10[Formula: see text] . CUORE , an array of 988 TeO[Formula: see text] bolometers being commissioned at Laboratori Nazionali del Gran Sasso, features an expected sensitivity of 50–130[Formula: see text] at 90 % C.L. The background is expected to be dominated by [Formula: see text] radioactivity, and can be in principle removed by detecting the small amount of Cherenkov  light emitted by the [Formula: see text] signal. The Cryogenic wide-Area Light Detectors with Excellent Resolution project aims at developing a small prototype experiment consisting of TeO[Formula: see text] bolometers coupled to high-sensitivity light detectors based on kinetic inductance detectors. The R&D is focused on the light detectors in view of the implementation in a next-generation neutrinoless double-beta decay experiment. Springer Berlin Heidelberg 2015-07-31 2015 /pmc/articles/PMC4528268/ /pubmed/26269692 http://dx.doi.org/10.1140/epjc/s10052-015-3575-6 Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. Funded by SCOAP3.
spellingShingle Regular Article - Experimental Physics
Battistelli, E. S.
Bellini, F.
Bucci, C.
Calvo, M.
Cardani, L.
Casali, N.
Castellano, M. G.
Colantoni, I.
Coppolecchia, A.
Cosmelli, C.
Cruciani, A.
de Bernardis, P.
Di Domizio, S.
D’Addabbo, A.
Martinez, M.
Masi, S.
Pagnanini, L.
Tomei, C.
Vignati, M.
CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors
title CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors
title_full CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors
title_fullStr CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors
title_full_unstemmed CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors
title_short CALDER: neutrinoless double-beta decay identification in TeO[Formula: see text] bolometers with kinetic inductance detectors
title_sort calder: neutrinoless double-beta decay identification in teo[formula: see text] bolometers with kinetic inductance detectors
topic Regular Article - Experimental Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4528268/
https://www.ncbi.nlm.nih.gov/pubmed/26269692
http://dx.doi.org/10.1140/epjc/s10052-015-3575-6
work_keys_str_mv AT battistellies calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT bellinif calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT buccic calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT calvom calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT cardanil calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT casalin calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT castellanomg calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT colantonii calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT coppolecchiaa calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT cosmellic calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT cruciania calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT debernardisp calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT didomizios calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT daddabboa calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT martinezm calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT masis calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT pagnaninil calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT tomeic calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors
AT vignatim calderneutrinolessdoublebetadecayidentificationinteoformulaseetextbolometerswithkineticinductancedetectors