Cargando…
Airway Obstruction after Acute Ozone Exposure in BALB/c Mice Using Barometric Plethysmography
BACKGROUND: Airway responsiveness after acute inhalation of ozone is related to the concentration and duration of ozone exposure. Using barometric whole-body plethysmography and increase in enhanced pause (P(enh)) as an index of airway obstruction, we measured the response of BALB/c mice to acute oz...
Autores principales: | Jang, An Soo, Choi, Inseon S, Kim, Sun Wook, Song, Byung Cheol, Yeum, Chung Ho, Jung, Joo Young |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association of Internal Medicine
2003
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4531606/ https://www.ncbi.nlm.nih.gov/pubmed/12760261 http://dx.doi.org/10.3904/kjim.2003.18.1.1 |
Ejemplares similares
-
Characterisation of Brachycephalic Obstructive Airway Syndrome in French Bulldogs Using Whole-Body Barometric Plethysmography
por: Liu, Nai-Chieh, et al.
Publicado: (2015) -
Whole‐Body Barometric Plethysmography Characterizes Upper Airway Obstruction in 3 Brachycephalic Breeds of Dogs
por: Liu, N‐C., et al.
Publicado: (2016) -
Evaluation of barometric whole-body plethysmography for therapy monitoring in cats with feline lower airway disease
por: Gareis, Hannah, et al.
Publicado: (2022) -
Prolonged ozone exposure in an allergic airway disease model: Adaptation of airway responsiveness and airway remodeling
por: Jang, An-Soo, et al.
Publicado: (2006) -
Respiratory Inductance Plethysmography calibration for pediatric upper airway obstruction: an animal model
por: Khemani, Robinder G., et al.
Publicado: (2014)