Cargando…

Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report

A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dur...

Descripción completa

Detalles Bibliográficos
Autores principales: JITO, Junya, NITTA, Naoki, NOZAKI, Kazuhiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japan Neurosurgical Society 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4533490/
https://www.ncbi.nlm.nih.gov/pubmed/24305019
http://dx.doi.org/10.2176/nmc.cr.2013-0010
_version_ 1782385347100934144
author JITO, Junya
NITTA, Naoki
NOZAKI, Kazuhiko
author_facet JITO, Junya
NITTA, Naoki
NOZAKI, Kazuhiko
author_sort JITO, Junya
collection PubMed
description A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with fibrin glue, before 2 years until the adoption of the new material. These patients underwent posterior fossa craniotomy and discharged without remarkable CSF leak. The pseudomeningocele under the occipital wound caused the CSF leak occurr from 5th to 7th week postoperatively. All CSF leak cases needed surgical repair. At the repair, the PEG hydrogel was liquefied and almost absorbed. A fistula on the closure line and a dead space after the absorption of the PEG hydrogel was observed. When the absorbable PEG hydrogel sealant plugs in small gaps of sutured dura, its properties to prevent adhesion might suppress healing process of dural closure, so that CSF could leak through the gaps and collect as a pseudomeningocele in the dead space after absorption of the PEG hydrogel. In posterior fossa surgery a PEG hydrogel sealant should be applied when dural edges are closed tightly without any gaps.
format Online
Article
Text
id pubmed-4533490
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Japan Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-45334902015-11-05 Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report JITO, Junya NITTA, Naoki NOZAKI, Kazuhiko Neurol Med Chir (Tokyo) Case Report A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with fibrin glue, before 2 years until the adoption of the new material. These patients underwent posterior fossa craniotomy and discharged without remarkable CSF leak. The pseudomeningocele under the occipital wound caused the CSF leak occurr from 5th to 7th week postoperatively. All CSF leak cases needed surgical repair. At the repair, the PEG hydrogel was liquefied and almost absorbed. A fistula on the closure line and a dead space after the absorption of the PEG hydrogel was observed. When the absorbable PEG hydrogel sealant plugs in small gaps of sutured dura, its properties to prevent adhesion might suppress healing process of dural closure, so that CSF could leak through the gaps and collect as a pseudomeningocele in the dead space after absorption of the PEG hydrogel. In posterior fossa surgery a PEG hydrogel sealant should be applied when dural edges are closed tightly without any gaps. The Japan Neurosurgical Society 2014-08 2013-12-05 /pmc/articles/PMC4533490/ /pubmed/24305019 http://dx.doi.org/10.2176/nmc.cr.2013-0010 Text en © 2014 The Japan Neurosurgical Society This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Case Report
JITO, Junya
NITTA, Naoki
NOZAKI, Kazuhiko
Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
title Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
title_full Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
title_fullStr Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
title_full_unstemmed Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
title_short Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
title_sort delayed cerebrospinal fluid leak after watertight dural closure with a polyethylene glycol hydrogel dural sealant in posterior fossa surgery: case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4533490/
https://www.ncbi.nlm.nih.gov/pubmed/24305019
http://dx.doi.org/10.2176/nmc.cr.2013-0010
work_keys_str_mv AT jitojunya delayedcerebrospinalfluidleakafterwatertightduralclosurewithapolyethyleneglycolhydrogelduralsealantinposteriorfossasurgerycasereport
AT nittanaoki delayedcerebrospinalfluidleakafterwatertightduralclosurewithapolyethyleneglycolhydrogelduralsealantinposteriorfossasurgerycasereport
AT nozakikazuhiko delayedcerebrospinalfluidleakafterwatertightduralclosurewithapolyethyleneglycolhydrogelduralsealantinposteriorfossasurgerycasereport